GRANDSTREAM GHP610W, GHP611W Compact Hotel Phone Installation Guide
- June 3, 2024
- GRANDSTREAM
Table of Contents
GRANDSTREAM GHP610W, GHP611W Compact Hotel Phone
The GHP610/W and GHP611/W are not pre-configured to support or carry emergency calls to any type of hospital, law enforcement agency, medical care unit (“Emergency Service(s)”) or any other kind of Emergency Service. You must make additional arrangements to access Emergency Services. It is your responsibility to purchase SIP-compliant Internet telephone service, properly configure the GHP610/W GHP611/W to use that service, and periodically test your configuration to confirm that it works as you expect. If you do not do so, it is your responsibility to purchase traditional wireless or landline telephone services to access Emergency Services.
GRANDSTREAM DOES NOT PROVIDE CONNECTIONS TO EMERGENCY SERVICES VIA THE GHP610/W AND THE GHP611/W. NEITHER GRANDSTREAM NOR ITS OFFICERS, EMPLOYEES OR AFFILIATES MAY BE HELD LIABLE FOR ANY CLAIM, DAMAGE, OR LOSS. YOU HEREBY WAIVE ANY AND ALL SUCH CLAIMS OR CAUSES OF ACTION ARISING FROM OR RELATING TO YOUR INABILITY TO USE THE GHP610/W AND GHP611/W TO CONTACT EMERGENCY SERVICES, AND YOUR FAILURE TO MAKE ADDITIONAL ARRANGEMENTS TO ACCESS EMERGENCY SERVICES IN ACCORDANCE WITH THE IMMEDIATELY PRECEDING PARAGRAPH.
The GNU GPL license terms are incorporated into the device firmware and can be accessed via the Web user interface of the device at http(s)://IP/gpl_license. To obtain a CD with GPL source code information please submit a written request to info@grandstream.com
PRECAUTIONS
WARNING: Please DO NOT power cycle the GHP610/W and GHP611/W during system boot up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction.
WARNING: Use only the power adapter included in the GHP610/GHP611 package. Using an alternative non-qualified power adapter may possibly damage the unit.
OVERVIEW
The GHP61X is a delicate IP Phone featuring one HD speaker on handset, 2 SIP
accounts/lines, 3 programmable keys and 10 speed dial keys. It also support .
Wi-Fi (GHP610W/GHP611W), 3-way voice conferencing, using full band Opus voice
codec and advanced jitter-resilience algorithm that tolerate up to 30% packet
loss without impacting voice quality. The GHP61X series is supported by
Grandstream’s Device Management System (GDMS), which provides a centralized
interface to configure, provision, manage and monitor deployments of
Grandstream endpoints. And it suitable for GDS37xx door control function.
GHP61X series IP phone can be installed on desktop or wall-mounted, and can be
powered by PoE (GHP610/GHP611) or power adapter (GHP610W/ GHP611W). Its
elegant and compact design make it perfect for not only hotels, but also
hospital, apartments, dormitories and much more.
PACKAGE CONTENT
1x Base
|
1x Handset
|
1x Phone Cord
---|---|---
1x 12V Power Adapter (Only with GHP610W and GHP611W)
1x Quick Installation Guide
GHP610/W & GHP611/W DESCRIPTION
WALL MOUNT
- Mark two dots horizontally with 100 mm in between where to wall mount the GHP610/W & GHP611/W.
- Using a drill, make a hole on each marked dot. Put a plastic expansion bolt and screw (not provided) on each hole. Leave enough space on the screws to mount the GHP610/W & GHP611/W.
- Mount the GHP610/W & GHP611/W on the screws using its “Wall Mount Slots”.
CONNECTING THE PHONE
To setup the phone, follow the steps below:
- Connect the handset (RJ-11 port) and the base with the phone cord.
- Connect the LAN port of the phone to the RJ-45 socket of a hub/switch or a router (LAN side of the router) using the Ethernet cable. This step can be skipped, if using GHP610W & GHP611W with Wi-Fi.
- Powering the phone:
• For GHP610W & GHP611W: Connect the 12V DC output plug to the power jack on the phone; plug the power adapter into an electrical outlet.
• For GHP610 & GHP611: A PoE switch must be used in step 2.
Note: For easy deployment, the GHP610W/GHP611W is out of the box preconfigured to connect to a default SSID named wp_master with a password (WPA/WPA2 PSK) equal to wp!987@dmin, users can adapt these settings from the web UI as well to make it easier for deployment on customer site.
PHONE CONFIGURATION
- Ensure your phone is powered up and connected to the Internet.
- Locate the MAC address on the MAC tag of the unit, which is on the underside of the device, or on the package.
- From a computer connected to same network as the GHP61X, type in following address using GHP61X’s MAC address on your browser: https://
.local Example: https://3ff765dcc282.local Note: The user can also dial **47# and the IP address will be read by the IVR. - Enter admin’s username and password to access the configuration menu. (The factory default username is “admin” while the default random password can be found on the sticker at the back of the unit).
Refer to online documents and FAQ for more detailed information: https://www.grandstream.com/our-products
For certification information, please refer to User Manuals: http://www.grandstream.com
Common part
This equipment complies with radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
U.S. FCC Part 68 Regulatory Information
This equipment complies with Part 68 of the FCC rules. Located on the
equipment is a label that contains, among other information, the ACTA
registration number and ringer equivalence number (REN.) If requested, this
information must be provided to the telephone company.The REN is used to
determine the quantity of devices which may be connected to the telephone
line. Excessive REN’s on the telephone line may result in the devices not
ringing in response to an incoming call. In most, but not all areas, the sum
of the REN’s should not exceed five (5.0). To be certain of the number of
devices that may be connected to the line, as determined by the total REN’s
contact the telephone company to determine the maximum REN for the calling
area.
This equipment cannot be used on the telephone company-provided coin service. Connection to Party Line Service is subject to State Tariffs.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right the file a complaint with the FCC if you believe it is necessary. The telephone company may makechanges in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.
If the trouble is causing harm to the telephone network, the telephone company may request you to remove the equipment from the network until the problem is resolved. This equipment uses the following USOC jacks: RJ45C. It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightening strikes and other electrical surges.
If trouble is experienced with this equipment, please contact (Agent in the
US): Company Name: Grandstream Networks, Inc.
Address: 126 Brookline Ave, 3rd Floor
Boston, MA 02215, USA
Tel: 1-617-5669300
Fax: 1-617-2491987
U.S. FCC Part 15 Regulatory Information
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note : This equipment has been tested
and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Specific Absorption Rate (SAR) information: The SAR limit of USA (FCC) is 1.6(for Head)&4.0(for Limbs) W/kg averaged over one gram of tissue. This model (FCC ID: YZZGHP61XW) has also been tested against this SAR limited. The highest SAR value reported under this standard during product certification for use at the Head is 1.211 W/kg and Limbs is 2.895 W/kg. SAR is evaluated with 0 mm separation.
Canada Regulatory Information
Radio equipment Operation of 5150-5250 MHz is restricted to indoor use only. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not causeinterference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Terminal equipment This product meets the applicable Innovation, Science and Economic Development Canada technical specifications. The Ringer Equivalence Number (REN) indicates the maximum number of devices allowed to be connected to a telephone interface. The termination of an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices not exceed five
EU Regulatory Information
In all EU member states, operation of 5150-5350 MHz is restricted to indoor use only. Support Frequency Bands and Power: WLAN 2.4 GHz < 20 dBm; WLAN 5.2 GHz < 23 dBm; WLAN 5.3/ 5.6 GHz < 20 dBm; The SAR testing has been carried out at a separation distance of 0 mm. Report SAR-10g for Head:0.241 W/kg. Report SAR-10g for Limbs:0.981 W/kg. The simplified EU declaration of conformity referred to in Article 10(9) shall be provided as follows: Hereby, [Grandstream Networks, Inc.] declares that the radio equipment type [GHP611W,GHP610W] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.grandstream.com
UK Regulatory Information
Operation of 5150-5350 MHz is restricted to indoor use only. Support Frequency Bands and Power: WLAN 2.4 GHz < 20 dBm; WLAN 5.2 GHz < 23 dBm; WLAN 5.3/ 5.6 GHz < 20 dBm; The SAR testing has been carried out at a separation distance of 0 mm. Report SAR-10g for Head:0.241 W/kg. Report SAR-10g for Limbs:0.981 W/kg. The simplified UK declaration of conformity referred to in Regulation 8&14 shall be provided as follows: Hereby, [Grandstream Networks, Inc.] declares that the radio equipment type [GHP611W,GHP610W] is in compliance with RER2017(S.I.2017/1206). The full text of the UK declaration of conformity is available at the following internet address: www.grandstream.com
In the UK and EU member states, operation of 5150-5350 MHz is restricted to indoor use only.
For Certification, Warranty and RMA information, please visit www.grandstream.com
Documents / Resources
|
GRANDSTREAM GHP610W, GHP611W Compact Hotel
Phone
[pdf] Installation Guide
GHP61XW, YZZGHP61XW, GHP610W GHP611W Compact Hotel Phone, GHP610W, GHP611W,
Compact Hotel Phone, GHP610W Compact Hotel Phone, GHP611W Compact Hotel Phone,
Hotel Phone, Phone
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>