Clean Air CA-507 Smart Clean Optima Air Purifier User Manual

June 1, 2024
Clean Air

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual

Clean Air CA-507 Smart Clean Optima Air Purifier User
Manual

www.cleanairoptima.com/info/manuals

Read these instructions carefully before you start using the Air Purifier and keep the manual for future reference © Copyright: Clean Air Optima®

Thank you for purchasing the Clean Air Optima Air Purifier CA-507 Smart.
We wish you many years of healthy indoor air with this efficient and effective product.

Ensure that all safety precautions are followed when using this electrical appliance for the proper operation of the device. These instructions describe the safety precautions to be observed during operation. They are meant to prevent injuries and to avoid damaging the device.

Before using your new Clean Air Optima Air Purifier CA-507 Smart.
Remove the sealing from the filters first, see page 4. How to use.

CA-507 Smart / Description of the device

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual - CA-507
Smart

  1. Control panel
  2. Air quality indicator
  3. Power cord
  4. Power adapter
  5. True HEPA H13 filter, active carbon filter and pré filter
  6. Adapter opening

Safety warnings

This device may only be used in accordance with this safety instructions. Take the following steps to minimize the risk of personal injury caused by for example electric shocks or fire.

  1. Only for indoor use. Do not use or store outdoors.

  2. This device can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and user maintenance shall not be made by children without supervision.

  3. Do not use the device when there is visible damage on the electrical cord or on the device
    itself. Do not repair the device yourself in case of damage. Never pull the device by its cord. If the power cord is damaged, then it must be replaced by an authorized service person to prevent electric shock or fire.

  4. Repairs may only performed by authorized service personal. Do not try to repair the device yourself to prevent electric shock or fire.

  5. Always remove the plug from the cord when the device is not being used.

  6. Only use power power adapters and cords provided. Check if adapter voltage matches local voltage.

  7. Pull the plug when you do not use the device or when you clean internal or external parts of it.

  8. For safety use put the device in a steady, horizontal position. Do not move while using.

  9. Do not use the device in rooms where inflammable liquids or gases are stored, close to heat sources or in particular humid rooms like the bathroom.

  10. Never insert any other object into the body to avoid breakdown.

  11. Never cover the air inlet and air outlet grid.

  12. Never dissemble or replace the device’s inner parts.

  13. When the device is running, do not touch the air inlet and outlet grilles, and do not insert the handle or any object into the air outlet to avoid injury or damage to the air purifier.

  14. To keep the inlet and outlet air grille of the air purifier unimpeded, do not place objects above or near the front cover of the air purifier.

  15. Do not put heavy objects on the unit.

  16. Please avoid places with direct sunlight. There is a risk that the device discolours.

  17. Never immerse the unit in water or other liquids.

  18. Do not touch the power cord with wet hands.

  19. Clean the Pre-filter regularly, if the Pre-filter is saturated with dust, it will lead to poor purifying effect. The power consumption will increase, it can cause failure.

  20. The normal operating environment of the device is 10 °C to 45 °C degrees.

  21. Use, maintain and clean the device as described in this manual.

How to use

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual - How to
use

Do not use the device with the filter removed. Insert the adapter into the adapter opening on the back of the air purifier and plug it into the wall socket. You will hear one beep and the air quality indicator light will go on and then go off. The device needs to be positioned at least 30 cm from walls and furniture to obtain a good air flow. Make sure that the air in-and outlets are not blocked.

Control Panel / Operation Instruction

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual - Control
Panel Clean Air CA-507
Smart Clean Optima Air Purifier User Manual - Control
Panel Clean Air CA-507
Smart Clean Optima Air Purifier User Manual - Control
Panel

Digital Monitor

The digital monitor on the top of the air purifier CA-507 Smart indicates automatically and exactly current air quality by measuring the level of Particle measurement PM2.5

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual - Digital
Monitor

Particulate matter of 10um (PM10) and smaller 2,5 um (PM2.5) can get into the lungs and belongs to the top 10 threats for human health. These small particles develop through typical indoor processes such as cooking, baking, frying, smoking, as well as heating or are also transported in big quantities into indoor air because of transportation, industry, construction, biological material (pollen, bacteria, mites, and viruses), imported particles from other regains such as (airplane) exhaust gases and volcano eruptions.

Allergens such as pollen and dust cause serious and long-term health threats to millions of persons each spring: the numbers are increasing constantly.

Measurement of relative humidity and temperature
Important aspects for effective air purification: relative humidity between 45 – 60% and room temperature of about 20 – 23 °C.

Operation with Clean Air Optima® App

Connectivity
Compatibility with smartphone and tablet:
iPhone, iPad and Android devices

Device connets via WiFi with App:
Clean Air Optima

Attention: The router must be set to the 2.4 GHz broadband. If the router is set to the 5.0 GHz, it is impossible to establish a connection.

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual -
Connectivity

Google Play
App Store

Set up WiFi connection

  1. Download and install the Clean Air Optima® App in the App Store or Google Play Store.

  2. Make an account and log in.

  3. Plug the device into the power socket and switch it on. After power on, long press the WIFI
    button for 3 seconds, the WIFI indicator light will flash quickly. The connection can be started, only when the WIFI indicator light flashes.

  4. The router must be set to the 2.4 GHz broadband. If the router is set to the 5.0 GHz, no connection can be established.

  5. Make sure Bluetooth is enabled on your smartphone.

  6. Make sure that your smartphone or tablet is successfully connected to your WiFi network.

  7. Open the Clean Air Optima® App and click on Add device’ . Your device is listed and you can select it. If not chooseAuto Scan’. Follow the on-screen instructions to connect the device to your network.

  8. Choose to add the Clean Air Optima® device on the App, follow the instructions in the App.

  9. When the device is paired, the WiFi indicator light stays on constantly.

  10. After the configuration is successful, you can use the Clean Air Optima® App to operate the device.

Note:

  • If your default network has changed, reset the WiFi connection, follow step 3 to 8 in the `Set up WiFi connection’ section.
  • If you want to pair multiple devices to your smartphone or tablet, you have to do this one after the other.
  • Make sure that the distance between your smartphone or tablet and the device is less than 5 meters and there are no obstacles. Also make sure you are in the same room as the device.

Reset the WiFi function:
– Reset the WiFi by pressing the `WiFi’ button for 3 seconds, the indicator light of the WiFi will blink rapidly.

Connect devices to multiple phones

Note: First the other person needs to install the Clean Air Optima® App on his/her phone and create a new account.

Share the device with limited access:
You can choose to share 1 device with several persons. This person will then have access, but will not be able to manage all the settings. Follow the instructions below to share the device with several persons:

  1. Go to the relevant device.
  2. Go to the pencil or three dots in the top right.
  3. Select Share device.
  4. Choose Add sharing.
  5. Choose the sharing method e.g. via email, whatsapp, sms etc. and continue.
  6. The device will automatically appear in the Clean Air Optima® App with the other account.

Share device with full access:
You can add a person or several persons to your home management. That person will then have access to all your devices that are already linked and has full rights and permissions. You will always remain the main administrator. Follow the instructions below to add someone to your home management:

  1. Open the Clean Air Optima® App and go to `Me’.
  2. Then choose `Home Management’.
  3. Choose Create a home’.
  4. Select the relevant Home’ andAdd member`.
  5. Choose the sharing method e.g. via email, whatsapp, sms etc. and continue.
  6. The corresponding Home will automatically appear in the Clean Air Optima® App of the person with whom you have shared your Home.
  7. On the other account:
    Go to the home screen from the Clean Air Optima® App. Go to the top left and select the Home.

Maintenance

Cleaning the outside of the air purifier

  1. Switch off the device and pull the plug.
  2. Use a soft and humid piece of cloth to clean the device from dust and dirt.
  3. Make sure that no water gets into the device.

Cleaning of the Intelligent Particle SensorTM Clean the air quality sensor every 6 to 8 weeks.
When the value of PM 2.5 is displayed incorrectly, a cotton swab can be used to clean the sensor lens.

  1. Remove the cover of sensor.

  2. Clean the sensor lens with a cotton swab and water as indicated by the arrow.
    Then dry the lens with a clean cotton swab.

  3. Install the cover of sensor.

  4. Do not wipe the sensor lens with alcohol or other organic solvent.

Attention! If the humidity in the room is very high, there is a risk of condensation on the air quality sensor. This may cause the air quality indicator (Digital Display – Particle Measurement) to indicate that the air quality is poor, while this should not be the case. In this case, we recommend that you clean the air quality sensor or do not use the air purifier in automatic mode.

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual -
Maintenance

Clean Air Optima® air purifier storage

  1. Unplug the device and fold up the power supply cord.
  2. Remove and clean the filters. After cleaning reinstall the filters back into the device.
  3. It is recommended to wrap the Filter and the unit in a plastic bag and place in a cool, dry area.
    Avoid moisture as it can damage the True HEPA filter.

Replacing of filters

The Clean Air Optima Air Purifier CA-507 Smart is equipped with a filter lifespan surveillance mechanism that signals that the filters have to be replaced after 1400 working hours. To show that the composite filters (HEPA + Activated Carbon Filter) need to be replaced, the indicator light will light up, and the device emits a double zero indicator light. Reset the timer for the filter by pressing and holding the sleep button for about 3 seconds. If the indicator light goes out, the timer has been successfully reset.

Depending on the use, the composite filters (HEPA + Activated Carbon Filter) has a lifespan of approx. 4-5 months.

Filter cleaning
The best effect is reached by cleaning the filters once a month. If indoor air is extremely polluted, more cleaning can be required.

Clean the Pre-filter and the HEPA filter with a brush or your vacuum cleaner. That way bigger dust particles like lint, hair and dander of pets can be removed from the filter.

Warning! Do never wet or rinse the composite filters (HEPA + Activated Carbon Filter) with water.

Signs for used up filters
Increased sound, reduced air flow, congested filters, rising presence of smells. The filter needs to be replaced by a new one when the HEPA filter changes its color from white to grey or black. If the HEPA filter remains white, there is NO need to replace the filter.

How to order filters:
Contact Clean Air Optima Customer Service tel. + 31 (0) 742670145 or visit our webshop: https://www.cleanairoptima.com/-accessoires

Troubleshooting

The following is a troubling shooting guide to help you solve any issues that you may have using the Clean Air Optima Air Purifier CA-507 Smart.

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual -
Troubleshooting Clean Air CA-507 Smart Clean Optima Air Purifier User Manual -
Troubleshooting

WARNING!
If the above recommended solutions do not work, please contact Clean Air Optima technical support at the telephone number for your region. Do not attempt to disassemble, reassemble, or repair the device as this may void the warranty.

Specifications

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual -
Specifications

Service

Warranty Certificate for the Clean Air Optima Air Purifier CA-507 Smart.
Date of purchase: ……………………………………………………………………………………………………
Customers name: …………………………………………………………………………………………………..
Address: ………………………………………………………………………………………………………………………
Telephone: ………………………………………………………………………………………………………………….
Email: ……………………………………………………………………………………………………………………………
Seller’s name: …………………………………………………………………………………………………………..
Address: ………………………………………………………………………………………………………………………

  1. Please fill in completely this Warranty Certificate. Send it with the invoice and the unit, postage pre-paid and using the original packing box, to your distributor. Make sure to include the appropriate return postage for the package.
  2. Please enclose a short description of the damage, fault or malfunction, and the circumstances under which these problems arose.

The Clean Air Optima Air Purifier CA-507 Smart is subjected to strict testing procedures before leaving the factory. If within 2 years from the date of purchase the product does not perform according to the specifications, because of factory defects, the purchaser is entitled to free repairs or replacement of parts upon presentation of this warranty (provided that the malfunction or damage to the device and/or parts occurred under normal operating conditions). What is covered: All parts defective in material and workmanship. For how long: two years from purchase date. What we will do: Repair or replace any defective parts. Exclusions: Regular replacement filters.

Other Conditions
The provisions of this warranty are in lieu of any other written warranty whether express or implied, written or oral, including any warranty of merchantability or fitness for a particular purpose. The manufacturer’s maximum liability shall not exceed the actual purchase price paid by you for the product. In no event shall the manufacturer be liable for special, incidental, consequential, or indirect damages. This warranty does not cover a defect that has resulted from improper or unreasonable use or maintenance, faulty assembly, accident, natural catastrophes, improper packing, or unauthorized tampering, alteration, or modification as determined solely by us. This warranty is void if the label bearing the serial number has been removed or defaced.

Thank you for reading!

Clean Air CA-507 Smart Clean Optima Air Purifier User Manual - Social Media
icon

www.cleanairoptima.com
www.cleanairoptima.com
www.cleanairoptima.com/info/manuals
 www.youtube.com

Clean Air Optima International B.V. | David Ricardostraat 9-7 / 9-9 | 7559 SH Hengelo (ov) The Netherlands | Phone: +31 (0) 74 – 2670145

Clean Air Optima Germany GmbH | Enschedestraße 14 | 48529 Nordhorn | Germany Phone: +49 (0) 5921 879-121
E-mail: [email protected]
Internet: www.cleanairoptima.com

A guarantee for healthy indoor air quality!
More info: www.cleanairoptima.com

© 2023 Clean Air Optima, All rights reserved, Made in P.R.C

Trademarks owned by: Clean Air Optima Germany GmbH, Enschedestraße 14, 48529 Nordhorn, Germany

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Clean Air User Manuals

Related Manuals