Kyla KSEN-231 Smoke Detector User Guide
- June 1, 2024
- Kyla
Table of Contents
Kyla KSEN-231 Smoke Detector User Guide
PRODUCT DESCRIPTION
The Kyla Smoke Detector is a stand-alone smoke detector with an in-built 3.0V 1650mAh Lithium battery that can last for 10 years. It utilizes a photoelectric sensor that allows it to be more sensitive to detecting slow smoldering fires which generates thick black smoke and little heat.
Button
ACTION | REMARKS |
---|
Press Power button and hush button at the same time (red LED flash rapidly
with alarm)| Test Mode
Red LED flash every 10 seconds (9min-exit)| Hush Button
PLACEMENT TIPS
NOTE
- Smoke detector should be installed on ceiling along an escape route (e.g living room)
- To prevent false alarm, avoid installing in kitchens and bathrooms.
- For multi-storey homes, minimum 1 smoke detector per store is recommended.
- Remove “silicon protection cover” before use.
INSTALLATION GUIDE
Ceiling mount with screw.
Rotate clockwise until click
Press the hush button for 0.5sec, red LED will flash rapidly with alarm.
(If LED does not flash, please remove the main unit and attach to the selling
mount bracket again)
LED STATUS INDICATOR
A CTION | REMARKS |
---|---|
Red LED flash rapidly with alarm | Smoke Warning |
Red LED flashed once every 43 seconds and alarm once | Low Battery Warning |
Green LED flash 3 times every 43 seconds | Hysteresis Mode |
NOTE
- To confirm that the detector is operational, perform a regular button test.
- Should the device fail to operate correctly, please contact us.
- Should the device indicate a battery fault warning, replace the smoke detector.
PACKING CONTENT
Smoke Detector` x1 | Easy Start Guide x1 | Warranty Card x1 |
---|---|---|
Bracket x1 | Silicon Sleeve x1 | Plastic Anchors x2 |
Screws x2 |
TECHNICAL SPECIFICATIONS
Model | KSEN-231 |
---|---|
Power supply | 3.0V 1650mAh lithium battery(non-replaceable) |
Standby Current | ≤10µA |
Alarm Current | ≤100mA |
Sound Level | 85 dB(A) at 3 meters |
Smoke Sensor | Photoelectric Sensor |
Dimension | ø56.0mm x H50.0mm |
Operating Temperature | 0 to 45°C |
Non-Operating Temperature | -25 to 70°C |
Operating Humidity | 0% to 95% Relative Humidity(non-condensing) |
Non-Operating Humidity | 0% to 95% |
Regulatory Compliance | EN 14604:2005 |
Thank you for using Kyla product! Please keep this Easy Start Guide for future use. For support or help, visit kylaconnect.com
TEN-YEAR LIMITED WARRANTY
The Manufacturer warrants its enclosed smoke detector to be free from defects in materials and workmanship under normal use and service for a period of 2 Years from Date of purchase and 10 Years Battery Warranty. The Manufacturer makes no other express warranty for this smoke detector. No agent, representative, dealer or employee of the company has the authority to increase or alter the obligations or limitations of this Warranty.
The Manufacturer shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Manufacturer be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied.
The warranty is not valid unless the purchaser registers online within 14 days of purchase (with the proof of purchase). Thank you dear customer for purchasing our product! Please register your warranty online at: https://kylaconnect.com/e-warranty
To obtain service under this warranty, please contact Service Center at:
Tel: +65 6594 2288
Address: 31, Ubi Road 1, #01-05, Singapore 408694
Service Hours: Monday to Friday, 9:00am – 5:30pm (Closed on Weekends &
Public Holidays)
Email: Support@aztech.com
References
- Shop KYLA - Smart Home Products | WiFi Plug | Smart Station | Smart Ceiling Light
- Register your Kyla Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>