MAC FAUCETS AHD-3 Automatic Hand Dryer User Manual
- June 2, 2024
- MAC FAUCETS
Table of Contents
When Style Matters
Installation Instructions
User Manual
Automatic Hand Dryer
Model: AHD-3 & Model: AHD-5
AHD-3 Automatic Hand Dryer
Specifications
Stainless Steel Front Cover
110 – 120V
11.7 Amps
550 – 1200W
Hardwire Connection
HEPA Filter
All hardware necessary for
satisfactory installation
Tools Needed
Recommended Mounting Heights
From Floor to bottom of Hand Dryer
Men | 45” | (114cm) |
---|---|---|
Women | 43” | (109cm) |
Teenagers | 42” | (107cm) |
Small childrens | 34” | (86cm) |
Handicapped | 38” | (97cm) |
Drill hole
- Use the template provided inside of the box.
- Use a level to insure that the template is straight and level, the electrical box must be a 7/8” from the edge of template to the edge of the box.
- Use painters tape to hold the template in place.
- Drill holes for supplied plastic anchors.
- Place the plastic anchors in the holes and push them with the help of a lite hammer.
Shell remove
- Use Allen wrench from accessories bag to remove 2 countersunk screws from body shell.
- Pull the shell upward by hands to remove.
**** Please avoid damage to shell finish.
Mounting instructions
- Install Electrical Box inside the wall. Location is shown in 02 page 1, point 2 Electrical Box must be flush with the wall surface.
- Pass the electrical cable through the knock out hole before mounting hand dryer onto wall, leave 6”-8” of wire inside of the hand dryer.
- Affix hand dryer onto wall using the 4 supplied screws, fasten securily
Connect the hand Dryer
All wire connections MUST BE conducted by an experienced electrical
contractor. Connect to an independent 20 Amp circuit braker.Use the wire connectors provided.
Connect Black to Line, White to Neutral, Green to ground
Hand dryers MUST BE grounded to avoid personal injuries Connect the electrical
cable to the cable of the hand dryer (pre-installed)
NOTE: 110V ONLY
Connecting hand dryer to higher voltage will damage hand dryer and WILL void
warranty.
Shell installation
- Tighten the 2 countersunk screws on the shell.
External maintenance
-
Daily Use and Maintenance Clean with a soft dry cloth or towel.
Please use standard glass cleaner ONLY.
Please DO NOT use harsh solvents of any kind.
Using the wrong cleaning tools or supplies will cause damage to the unit and finish and WILL void warranty. -
Air filter maintenance Cleaning cycle: semi-annually or as needed
1. Remove Shell, see 06 above.
2. Open the air inlet panel, pull the air filter out and clean it.
3. Install shell back on, see 06 above.
Operation instructions
Place hands under sensor to activate.
Dryer will shut off a few seconds after hands are removed.
California, USA 866558 3200
310 919 3073
Info@macfaucets.com