MAC FAUCETS AHD-3 Automatic Hand Dryer User Manual

June 2, 2024
MAC FAUCETS

MAC FAUCETS Logo When Style Matters
Installation Instructions
User Manual
Automatic Hand Dryer
Model:
AHD-3 & Model: AHD-5

AHD-3 Automatic Hand Dryer

Specifications

SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 Stainless Steel Front Cover
SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 110 – 120V
SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 11.7 Amps
SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 550 – 1200W
SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 Hardwire Connection
SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 HEPA Filter
SEALEY VS0220 Brake and Clutch Bleeder Pneumatic Vacuum - Symbol
5 All hardware necessary for satisfactory installation

Tools Needed

MAC FAUCETS AHD-3 Automatic Hand Dryer - Tools Needed

Recommended Mounting Heights

From Floor to bottom of Hand Dryer

Men 45” (114cm)
Women 43” (109cm)
Teenagers 42” (107cm)
Small childrens 34” (86cm)
Handicapped 38” (97cm)

Drill hole

MAC FAUCETS AHD-3 Automatic Hand Dryer - Drill hole

  1. Use the template provided inside of the box.
  2. Use a level to insure that the template is straight and level, the electrical box must be a 7/8” from the edge of template to the edge of the box.
  3. Use painters tape to hold the template in place.
  4. Drill holes for supplied plastic anchors.MAC FAUCETS AHD-3 Automatic Hand Dryer - Drill hole 2
  5. Place the plastic anchors in the holes and push them with the help of a lite hammer.

Shell remove

MAC FAUCETS AHD-3 Automatic Hand Dryer - Shell remove

  • Use Allen wrench from accessories bag to remove 2 countersunk screws from body shell.
  • Pull the shell upward by hands to remove.

**** Please avoid damage to shell finish.

Mounting instructions

  • Install Electrical Box inside the wall. Location is shown in 02 page 1, point 2 Electrical Box must be flush with the wall surface.
  • Pass the electrical cable through the knock out hole before mounting hand dryer onto wall, leave 6”-8” of wire inside of the hand dryer.
  • Affix hand dryer onto wall using the 4 supplied screws, fasten securily

MAC FAUCETS AHD-3 Automatic Hand Dryer - Mounting
instructions

Connect the hand Dryer

All wire connections MUST BE conducted by an experienced electrical contractor. Connect to an independent 20 Amp circuit braker.MAC FAUCETS
AHD-3 Automatic Hand Dryer - Connect the hand DryerUse the wire connectors provided.
Connect Black to Line, White to Neutral, Green to ground
Hand dryers MUST BE grounded to avoid personal injuries Connect the electrical cable to the cable of the hand dryer (pre-installed)
NOTE: 110V ONLY
Connecting hand dryer to higher voltage will damage hand dryer and WILL void warranty.

Shell installation

MAC FAUCETS AHD-3 Automatic Hand Dryer - Shell
installation

  • Tighten the 2 countersunk screws on the shell.

External maintenance

  1. Daily Use and MaintenanceMAC FAUCETS AHD-3 Automatic Hand Dryer - Daily Use and Maintenance Clean with a soft dry cloth or towel.
    Please use standard glass cleaner ONLY.
    Please DO NOT use harsh solvents of any kind.
    Using the wrong cleaning tools or supplies will cause damage to the unit and finish and WILL void warranty.

  2. Air filter maintenanceMAC FAUCETS AHD-3 Automatic Hand Dryer - Air filter maintenance Cleaning cycle: semi-annually or as needed
    1. Remove Shell, see 06 above.
    2. Open the air inlet panel, pull the air filter out and clean it.
    3. Install shell back on, see 06 above. MAC FAUCETS AHD-3 Automatic Hand
Dryer - Air filter maintenance 2

Operation instructions

Place hands under sensor to activate.
Dryer will shut off a few seconds after hands are removed.

MAC FAUCETS AHD-3 Automatic Hand Dryer - Symbol 1 California, USA 866558 3200
310 919 3073
Info@macfaucets.com