ARITECH Axon x700 Control Panel Installation Guide

June 2, 2024
aritech

ARITECH Axon x700 Control Panel

 **Installation Guide**

Figure 1: Connections

Figure 2: Axon x700 PCB Layout

(1) Tamper contact socket
(2) NTC temperature sensor socket
(3) Legacy output expander interface
(4) Jumper for legacy output expander
(5) Output expander slot
(6) Power supply connector
(7) Siren connection terminals
(8) Zone input terminals (1 to 8) and auxiliary power
(9) Data bus 1 terminals
(10) Input expander slot
(11) Legacy input expander interface
(12) Input expander interface
(13) LEDs
(14) Ethernet RJ-45 connector
(15) USB connector (micro-A/B type)
(16) PIN bypass push button
(17) MI-bus connector for MI devices
(18) DIP switch
(19) Data bus 2 terminals
(20) Data bus 3 terminals (for future use)
(21) Cellular dialler slot
(22) Interface for add-on module
(23) Zone input terminals (9 to 16) and auxiliary power
(24) Relay output terminals (1 and 2)
(25) PCB cover
(26) Output expander interface

Note : Not all connectors may be available in particular Axon x700 panel variants. See Axon x700 Control Panel Installation and Programming Manual for details.

Figure 3: Medium metal housing MM+

Figure 4: Pry-off tamper mount

Quick Installation Guide

This Installation Sheet provides general information on Axon x700 Control Panel installation. For the complete information on control panel installation and programming, see Axon x700 Control Panel Installation and Programming Manual.

List of panel variants

  • ATS1700, ATS3700: Medium metal enclosure MM+

Warnings and cautions

Caution: Hot parts! Risk of burn. Burned fingers when handling parts. Allow parts to cool down before handling.

WARNING! Dangerous voltage! Risk of injury or death. Fuse may be in the neutral. The mains should be disconnected to de-energize the phase conductors.

WARNING! Using incorrect types of batteries may cause risk of fire, explosion, or chemical leakage. Use only types of batteries listed in “Specifications” on page 3. Disposal into fire, placing into a hot oven, leaving in an extremely high temperature surrounding environment, subjecting to extremely low air pressure, mechanically crushing or cutting of a battery can result in an explosion or leakage of flammable liquid or gas.

WARNING! If the housing cover is removed, there is no safeguard against electrically caused fire that might occur during system malfunction. The housing cover must be reassembled according to this installation instruction after each interference by a user.

WARNING: Electrocution hazard. To avoid personal injury or death from electrocution, remove all sources of power and allow stored energy to discharge before installing or removing equipment.

WARNING! The battery shield must be mounted during normal device operation.

WARNING! The correct earthing procedures must be followed.

WARNING! Use cables that comply with IEC 60332-1-2 and IEC 60332-1-3, or IEC 60332-2-2, or IEC TS 60695-11-21, or UL 2556 VW-
1. Use cables and connections that can withstand at least 2 A current.

Axon x700 housing
The housings with mounting holes (items 1) are shown in Figure 3.
Item 2 indicates the pry-off tamper wall stub location.
All dimensions are given in mm.
For pry-off tamper mounting, follow the steps in Figure 4.
Caution: NTC temperature sensor must be mounted close to the battery and connected to the panel PCB to comply with EN 50131 requirements. The sensor socket is shown in Figure 2 as Item 2.

Maintenance

The intrusion control panel is only allowed to be serviced by dedicated service personal. The screw of the housing is intended to protect the product from unintended use.
For metal housing, the screw is already installed out of the box. For plastic housing, the screw, available inside housing, should be mounted before first time use.
To open the housing, remove the housing screw and open the cover.
After the maintenance, replace the cover and fix it with the cover screw.

Mains power connection
Electrical installation should be carried out by a skilled person.
Solid insulation of the building mains cables should meet the technical and the environmental specifications of the equipment.
Use the mains connector terminal for connecting the AC mains supply.
A fixed cable or flexible mains lead to earthed mains outlet can be used. When fixed wiring is used, insert a dedicated all-pole circuit breaker in the power distribution network. In all cases the mains connection must comply with local regulations.
Always connect the building protective earthing wire and ensure the connection is reliable.
In case the panel is connected to the power grid using fixed wiring, it is recommended that earth wire is longer than line and neutral.
Do connect incoming line and neutral to mains connection block according to the label. This assures that the line will be protected by the mains fuse, and that service can be done by service personnel.
Make sure that before connecting the mains power, the mains power supply is disconnected.
When installing the mains power, use strain reliefs such as cable ties and coupling PG16s to ensure proper wiring and minimize the risk of wire damage during installation and use. If product entry hole breakouts are used, it is required to also make use of UL-V2 (or better) approved PG16 cable gland. Refer to PG16 specification to meet minimum and maximum cable diameters.

In all cases local regulations must be observed.

Battery installation and replacement

To install or replace the battery, do the following:

  1. Make sure that your product settings allow you to open its cover without starting the tamper alarm.
  2. Make sure that the mains power is off and remove the cover.
  3. If necessary, remove the battery shield, unscrewing four screws.
  4. If the old battery must be replaced, disconnect the battery. Note that depending on the battery model the connectors may be located differently.
  5. Remove the battery from the holder.
  6. Connect the new battery, sliding the product wires on the wire connectors. Note that depending on the battery model, the connectors can be located differently.
  7. Mount the battery shield using four screws.

Note : After every battery installation or replacement it is necessary to set battery capacity in the control panel settings. See Axon x700 Control Panel Installation and Programming Manual for details.

Mounting

The unit is mounted with screws or bolts through the mounting holes in the rear section of the enclosure.

Important : When the product is mounted to the wall, assure that at least 3 times the weight of the product can be supported. The product weight is the product itself plus battery and accessories.
Ensure that the unit is mounted on a flat, solid, vertical surface such that the base will not flex or warp when the mounting screws and bolts are tightened.

Leave a 50 mm clearance between equipment enclosures mounted side by side and 25 mm between the enclosure and the sidewall.

The rechargeable battery must not be fitted until the control panel is secured to the fixing surface. Under no circumstances should the panel be transported with a battery fitted.

Cabling
Refer to Axon x700 Control Panel Installation and Programming Manual for cabling details.

Other manuals
See Axon x700 Control Panel User Guide for more information on how to use the Axon x700 system.
See Axon x700 Control Panel Manager Manual for more information on system management.
See Axon x700 Control Panel Installation and Programming Manual for more information on system configuration and programming.
See SMS Control Reference Manual for more information on SMS commands.

Specifications

WARNING: Before removing the mains fuse, mains power must be disconnected (see “ Mains power connection” on page 3).

Regulatory information

https://firesecurityproducts.com/policy/product-warning/

https://firesecurityproducts.com/en/content/intrusion-intro

Contact information
firesecurityproducts.com or www.aritech.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals