ARITECH DC111 Magnetic Contact Installation Guide

June 13, 2024
aritech

ARITECH DC111 Magnetic Contact

Description
The DC111 is a triple-biased surface-mounted magnetic contact designed to be connected to a burglar alarm system. It provides additional security with a magnetic field tamper and pry-off tamper. The DC111 can be used on both ferromagnetic and nonferromagnetic environments and doors.

Mounting

  • To mount the DC111, ensure that the magnetic contact and the magnet are parallel to each other with the text facing the same direction. Use screws to secure them in place.
  • If pry-off tamper supervision is required, mount the tamper plate (item 1) in the desired position using the two middle holes (item 2), and then mount the contact. If necessary, install the magnet on the magnet spacer plate (item 3) to align the contact and magnet positions.
  • Note: The tamper plate (item 1) contains a separate magnet. Do not replace it with the magnet spacer plate (item 3) as it will cause the pry-off tamper supervision to fail.
  • During installation, ensure there is a minimum mounting distance between the magnetic contact and the magnet. This distance needs to be determined individually for each contact.
  • After installation, check the electrical switch function of the magnetic contact using a continuity checker or multimeter. Avoid using excessive mechanical force during installation to prevent damage to reed switches.
  • Note: Consider temperature influences that may cause doors to bend when installing the contact.

Wiring Description

Item Color Description
(4) White Alarm, normally closed
(5) Red/White Alarm, normally open
(6) Silver/White Alarm, COM
(7) Gold/White Tampere, COM
(8) Green/White Magnetic tamper, normally closed
(9) Blue/White Pry-off tamper normally closed

If the tamper plate is used, connect wires 7 and 9 to the tamper loop. Otherwise, use wires 7 and 8 instead.

Package Content

  • DC111 Magnetic Contact

Specifications

Cable length Switch close resistance
2.5 m 10 m

Mounted on non-ferromagnetic material:

| Approach distance X (switch close)| Removal distance X (switch open)| Approach distance Y (switch close)| Removal distance Y (switch open)| Approach distance Z (switch close)| Removal distance Z (switch open)
---|---|---|---|---|---|---
Minimum mounting distance between contact and magnet| 10 mm| 5 mm| 17 mm| 11 mm| 20 mm| 5 mm| 27 mm

Mounted on ferromagnetic material:

| Approach distance X (switch close)| Removal distance X (switch open)| Approach distance Y (switch close)| Removal distance Y (switch open)| Approach distance Z (switch close)| Removal distance Z (switch open)
---|---|---|---|---|---|---
Minimum mounting distance between contact and magnet| 8 mm| 5 mm| 17 mm| 9 mm| 20 mm| 4 mm| 19 mm

Contact Information:

  • Manufacturer: PLACED ON THE MARKET BY: Carrier Fire & Security Americas Corporation Inc.
  • Address: 13995 Pasteur Blvd, Palm Beach Gardens, FL 33418, USA.

Dimension

ARITECH-DC111-Magnetic-Contact-fig-1

Description

DC111 is a triple-biased surface-mounted magnetic contact that can be connected to a burglar alarm system. For additional security, it also includes a magnetic field tamper and pry-off tamper. DC111 can be used on ferromagnetic and non-ferromagnetic environments and doors.

Mounting

  • The magnetic contact and the magnet should be mounted parallel to each other and with the text facing the same direction, using screws.
  • If pry-off tamper supervision is required, mount the tamper plate (item 1) in the desired position using two middle holes (item 2), and then mount the contact. To align the contact and the magnet positions, if necessary, install the magnet on the magnet spacer plate (item 3).

Note:
The tamper plate (item 1) contains a separate magnet. Do not replace it with the magnet spacer plate (item 3), otherwise, the pry-off tamper supervision will fail.

Because this is a triple-biased contact, there is a minimum mounting distance between the magnetic contact and the magnet. This distance is:

  • For non-ferromagnetic material: minimum of 10 mm between magnetic contact and magnet.
  • For ferromagnetic material: minimum of 8 mm between magnetic contact and magnet.

During installation, the switching distances have to be individually determined for each contact. When the installation is completed, the electrical switch function of the magnetic contact must be checked (for example, with a continuity checker or multimeter). Use of mechanical force, for example, when installing, can damage glass bodies of reed switches.

Note:
When installing the contact please keep in mind that the doors can bend under temperature influence.

Wiring description

Item Color Description
(4) White Alarm, normally closed
(5) Red/White Alarm, normally open
(6) Silver/White Alarm, COM
(7) Gold/White Tamper, COM
(8) Green/White Magnet tamper normally closed
(9) Blue/White Pry-off tamper normally closed
--- --- ---

If the tamper plate is used, connect wires 7 and 9 to the tamper loop. Otherwise, use wires 7 and 8 instead.

Package content

  • 1X Magnetic Contact
  • 1X Magnet
  • 1X Tamper plate
  • 1X Magnet spacer plate
  • 2X Screws

Specifications

  • Cable length 2.5 m
  • Switch close resistance <2 Ω
  • Switch open resistance >10 MΩ

Mounted on non-ferromagnetic material

  • Minimum mounting distance between contact and magnet 10 mm
  • Approach distance X (switch close) 5 mm
  • Removal distance X (switch open) 17 mm
  • Approach distance Y (switch close) 11 mm
  • Removal distance Y (switch open) 20 mm
  • Approach distance Z (switch close) 5 mm
  • Removal distance Z (switch open) 27 mm

Mounted on ferromagnetic material

  • Minimum mounting distance between contact and magnet 8 mm
  • Approach distance X (switch close) 5 mm
  • Removal distance X (switch open) 17 mm
  • Approach distance Y (switch close) 9 mm
  • Removal distance Y (switch open) 20 mm
  • Approach distance Z (switch close) 4 mm
  • Removal distance Z (switch open) 19 mm
  • Contact type Change-over
  • Contact dimensions 108 x 38.1 x 19.1 mm
  • Magnet dimensions 108 x 38.1 x 19.1 mm
  • Maximum switch voltage 30 V==
  • Maximum switch current 0.25 A
  • Operating temperature
    • −28 to +65°C
    • EN 50131 Class II: −10 to +55°C

Regulatory information

Manufacturer

PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc. 13995 Pasteur Blvd Palm Beach Gardens, FL 33418, USA.

AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands.

Product warnings and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE AND INSTALLATION BY QUALIFIED PROFESSIONALS. CARRIER FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS. For more information on warranty disclaimers and product safety information, please check https://firesecurityproducts.com/policy/product-warning/ or scan the QR code.

  • Environmental class IP68

REACH

2012/19/EU (WEEE directive):
Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: recyclethis.info.

Contact information

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals