ARITECH VE1016 Series PIR Detector Installation Guide

June 13, 2024
aritech

ARITECH VE1016 Series PIR Detector

Introduction

The VE1016 series consists of models VE1016 and VE1016AM. These detectors use PIR or PIR-AM sensors. They have a patented mirror, pyro, and signal processing technology.

Installation guidelines

The technology used in these detectors resists false alarm hazards. However, avoid potential causes of instability such as (see Figure 1)

ARITECH-VE1016-Series-PIR-Detector-FIG-1

  • Direct sunlight on the detector
  • Strong draughts onto the detector
  • Heat sources within the detector field of view
  • Large animals within the detector field of view
  • Obscuring the detector field of view with large objects, such as furniture
  • Objects within 50 cm (20 in.) of the anti-masking (AM) detector
  • Installing two detectors facing each other and less than 50 cm (20 in.) apart

Installing the detector

  • (1) Standard connection (factory default)
  • (2) Dual loop connection
  • CP Control panel
  • WT Walk test
  • AM Antimasking
  • D/N Day/night
  • Rtest Remote test

ARITECH-VE1016-Series-PIR-Detector-FIG-7

To install the detector

  1. Lift off the custom insert and remove the screw (see Figure 2, step 1).
  2. Using a screwdriver, carefully prise open the detector (see Figure 2, steps 2 and 3).
  3. Fix the base to the wall. For flat mounting use a minimum of two screws (DIN 7998) in positions A. For corner-mounting, use screws in positions B or C (Figure 4). To install a pry-off tamper, use position A or B.
  4. Wire the detector (see Figures 4 and 7). ARITECH-VE1016-Series-PIR-Detector-FIG-5 ARITECH-VE1016-Series-PIR-Detector-FIG-6 ARITECH-VE1016-Series-PIR-Detector-FIG-7
  5. Select the desired jumper and DIP switch settings (see Figure 3). See section “Jumper settings” below for more information.ARITECH-VE1016-Series-PIR-Detector-FIG-3
  6. Remove the blinders and add the stickers, if required. See “Configuring the coverage pattern” on page 5 for more details.
  7. For ceiling-mount applications that require a 90° coverage, use the SB01 swivel-mount bracket.
  8. Close the cover.
  9. Insert the screw and place the custom insert.

For EN 50131 grade 3 installations, do not use mounting position C.

Jumper settings

  • See Figure 3 for the jumper locations in the detector.

J1: Not used

  • J2: PIR enabling the LED
  • On: Enables the detector LED at all times (default)
  • Off: Puts the LED under control of the control panel and disables the detector LED at all times (no memory feature)

J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect the detector to any control panel. Use jumpers 3 and 4. See Figure 7.

J5: D/N mode (Day/Night) or Rtest (remote test) setting

  • Use this jumper to set terminal 8 to either D/N or Rtest. We recommend that you use D/N to manage the AM/TF activation when required. Use Rtest to test the detector from the control panel. The detector will activate the Alarm relay if the test result is positive, and the AM relay if the test result is negative.
  • On: Terminal 8 = D/N (default)
  • Off: Terminal 8 = Remote test

J6: Polarity setting of the control voltage (CV)

  • On: “Active High” provides the standard logic with “Active High” logic to enable Walk Test (WT) and Day/Night inputs (default)
  • Off: “Active Low” provides “Active Low” logic to enable Walk Test and Day/Night inputs

Setting the detector: DIP switch setting

Factory default

SW 1: When to signal AM (anti-masking) or TF (technical fault) output

  • On: Signals AM or TF only when the system is in Day mode (factory default).
  • Off: Always signals AM or TF during Day and Night mode.

SW 2: AM sensitivity

  • On: Advanced AM sensitivity. The detector signals the AM area masking (factory default).
  • Off: Standard AM sensitivity. The detector signals the AM area approaching.

SW 3: Resetting the AM/TF output

  • On: Auto reset. Resets the AM or TF status 40 seconds after a PIR alarm.
  • Off: Authorized reset. Resets the AM or TF status after a PIR alarm when the system is in Day and Walk Test mode. The yellow LED will blink quickly. When the system is in Night status, the yellow LED will turn off and the system is reset (factory default).

Notes

  • For the advanced setting (SW 2 is On) the source of AM alarm needs to be removed before AM reset is allowed.
  • If the AM alarm cannot be reset with an auto reset or authorized reset, disconnect the power supply and reconnect again.
  • A walk test should be performed to ensure the device settings are appropriate for its application.

SW 4: Signaling AM or TF output

  • On: Signals AM on both the AM and Alarm relays. Signals TF on the AM relay only (EN 50131).
  • Off: Signals AM and TF on the AM relay (factory default).

SW 5: Setting LEDs

  • On: Enables both LEDs on the detector at all times (factory default).
  • Off: Puts both LEDs under the control of the Walk Test and Day/Night input. This activates the memory feature of the detector.

AM calibration

  • During start-up the AM circuitry calibrates itself to its environment. It is important to make sure that there are no changes made to the environment within 1 m distance of the detector within 60 s after powering up, otherwise the detector may be vulnerable to false AM alarms and these alarms may be impossible to reset.

Configuring the coverage pattern

  • Remove blinders (Figure 6, item 1) if necessary. The modified pattern is shown in Figure 6, items 3 to 7.
  • Note: If both blinders are installed, the detector range is limited to 6 m (default).
  • Modify the pattern by breaking out blinder parts (shown as gray in Figure 6, item 1). The corresponding curtain fragments are shown in Figure 6, item 2.
  • Put the appropriate mirror stickers if necessary. See Figure 8, item 1 for details.ARITECH-VE1016-Series-PIR-Detector-FIG-8
  • Caution: Removing stickers can damage the mirror surface.
  • When near objects directly under the detector, fit the mask to the inside of the window (default). This disables the part of the curtains looking down at the object, whose closeness might destabilize the detector. See Figure 8, item 2.

LED indication

ARITECH-VE1016-Series-PIR-Detector-FIG-10 ARITECH-VE1016-Series-PIR-Detector-FIG-11

Specifications

  VE1016 VE1016AM
Detector PIR PIR + AM
Signal processing V2E
Range 16 m (52 ft. 6 in.)
Optical 9 high-density mirror curtains
Memory No Yes
Input power 9 to 15 V (12 V nominal)
  VE1016 VE1016AM
--- --- ---
Peak-to-peak ripple 2 V (at 12 V

)

Detector start-up time| 25 s| 60 s
Normal current consumption| 5.5 mA| 10 mA
Current consumption in alarm| 1.1 mA| 3.8 mA
Maximum current consumption| 11 mA| 24 mA
Mounting height| 1.8 to 3.0 m (5.9 to 9.8 ft.)| 2.0 to 3.0 m (6.6 to 9.8 ft.)
Target speed range| 30 cm/s to 3 m/s

(1 ft./s to 10 ft./s)

| 20 cm/s to 3 m/s

(8 in./s to 10 ft./s)

Alarm (NC) / Tamper relay characteristic| 80 mA, 30 V| 80 mA, 30 V
Pry-off tamper| Optional| On-board (Yes)
AM relay characteristic| —| 80 mA at 30 V max.
Alarm time| 3 s
Operating temperature| −10 to +55°C (+14 to 130°F)
Dimensions (H x W x D)| 108 × 60 × 46 mm

(4.25 × 2.36 × 1.81 in.)

Relative humidity| 95% max.
Weight| 120 g (4.2 oz.)| 128 g (4.5 oz.)
IP/IK rating| IP30 IK02

Regulatory information

Manufacturer

  • PLACED ON THE MARKET BY:
  • Carrier Fire & Security Americas Corporation Inc.
  • 13995 Pasteur Blvd
  • Palm Beach Gardens, FL 33418, USA
  • AUTHORIZED EU REPRESENTATIVE:
  • Carrier Fire & Security B.V.
  • Kelvinstraat 7, 6003 DH Weert, Netherlands

Product warnings and disclaimers

  • THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS. CARRIER FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED
  • DEALER” OR “AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS.
  • For more information on warranty disclaimers and product safety information, please check  https://firesecurityproducts.com/policy/productwarning/. or scan the QR code.

ARITECH-VE1016-Series-PIR-Detector-FIG-14

European Union directives

  • Carrier Fire & Security hereby declares that this device is in compliance with the applicable requirements and provisions of the Directive 2014/30/EU and/or 2014/35/EU. For more information see firesecurityproducts.com or www.aritech.com.

REACH

  • Product may contain substances that are also Candidate List substances in a concentration above 0.1% w/w, per the most recently published Candidate List found at ECHA Web site. Safe use information can be found at  https://firesecurityproducts.com/en/content/intrusion-intro.
  • 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: recyclethis.info.

Product documentation

Please consult the following weblink to retrieve the electronic version of the product documentation. This link will guide you to the EMEA regional contact page. On this page you can request your login to the secured webportal where all manuals are stored.
https://firesecurityproducts.com/en/contact.

Contact information
firesecurityproducts.com or www.aritech.com.

BSIA Form No 185 — RECOMMENDATIONS TO MANUFACTURERS for the interpretation of detector standards: DD TS 50131-2-2:2008 Requirements for passive infrared detectors VE1016 has been tested and certified to EN 50131-2-2 for security grade 2, environmental class 2, by the Dutch testing and certification body Telefication B.V. VE1016AM has been tested and certified to EN 50131-2-2 for security grade 3, environmental class 2, by the Dutch testing and certification body Telefication B.V.

VdS

  • VE1016-D: VdS No: G110508, Class: B
  • VE1016AM-D: VdS No: G110028, Class: C

NF & A2P

  • VE1016
  • NF-A2P Nº: 2621100012

VE1016AM

  • NF-A2P Nº: 2621100011

CNPP certification

  • www.cnpp.com
  • AFNOR certification
  • www.afnor.org
  • UF146, Environmental Class II
  • Certified according to the standards:
  • EN 50131-2-2 – RTC50131-2-2 – NF324 H58

Important note VE1016AM: when installing in association with the SB01 ball joint, it is obligatory to use the tearing detection reference ST400, so that the product is complies with its NFA2P certification.