MITSUBISHI ELECTRIC MXZ-SM36NAM-U1 Multi-Zone Ductless Heat Pump Condenser User Manual

June 4, 2024
Mitsubishi Electric

MITSUBISHI-LOGO

MITSUBISHI ELECTRIC MXZ-SM36NAM-U1 Multi-Zone Ductless Heat Pump

Condenser

MITSUBISHI-ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
PRODUCT

SERVICE PARTS LIST

  • MXZ-SM36NAM-U1
  • MXZ-SM48NAM-U1
  • MXZ-SM60NAM-U1
  • MXZ-SM36NAMHZ-U1
  • MXZ-SM42NAMHZ-U1
  • MXZ-SM48NAMHZ-U1

MITSUBISHI-ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG1

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.

|

Parts No.

|

Parts Name

| MXZ-SM36NAM-U1| MXZ-SM48NAM-U1| MXZ-SM60NAM-U1| MXZ- SM36NAMHZ-U1| MXZ-SM42NAMHZ-U1| MXZ-SM48NAMHZ-U1|

Remarks

---|---|---|---|---|---|---|---|---|---
1| R 0 1  E 3 0  6 6 2| SIDE PANEL (L)| 1| 1| 1| 1| 1| 1|
2| R 0 1  E 7 3  6 9 1| WIRE GRILLE| 2| 2| 2| 2| 2| 2|
3| R 0 1  E 0 5  6 5 5| HANDLE (FRONT)| 2| 2| 2| 2| 2| 2|
4| R 0 1  E 2 3  6 6 8| FRONT PANEL| 1| 1| 1| 1| 1| 1|
5| T 7 W  E 3 5  6 8 6| BASE ASSY| 1| 1| 1| 1| 1| 1|
6| T 7 W  E 0 5  6 1 7| CONDUIT PLATE| 1| 1| 1| 1| 1| 1|
7| R 0 1  E 3 5  6 5 8| COVER PANEL (FRONT)| 1| 1| 1| 1| 1| 1|
8| R 0 1  E 3 6  6 5 8| COVER PANEL (REAR)| 1| 1| 1| 1| 1| 1|
9| R 0 1  E 0 6  6 5 5| HANDLE (REAR)| 2| 2| 2| 2| 2| 2|
10| R 0 1  E 8 1  6 6 1| SIDE PANEL (R)| 1| 1|  |  | |  |
10| R 0 1  E 7 4  6 6 1| SIDE PANEL (R)|  |  | 1| 1| 1| 1|
11| T 7 W  E 2 8  6 6 8| SERVICE PANEL| 1| 1|  | |  |  |
11| T 7 W  E 2 4  6 6 8| SERVICE PANEL|  |  | 1| 1| 1| 1|
12| R 0 1  E 3 6  6 4 1| TOP PANEL| 1| 1| 1| 1| 1| 1|
13| R 0 1  E 1 0  6 9 8| REAR GUARD| 1| 1| 1| 1| 1| 1|
14| R 0 1  E 5 9  1 3 0| MOTOR SUPPORT| 1| 1|  | 1| 1| 1|
14| R 0 1  E 6 0  1 3 0| MOTOR SUPPORT|  |  | 1|  |  | |
15| T 7 W  B 0 3  0 0 5| BRAND LABEL/SM| 1| 1| 1| 1| 1| 1|
16| T 7 W  A 1 0  0 0 5| LABEL (H2I)|  |  |  | 1| 1| 1|

FUNCTIONAL PARTS

  • MXZ-SM36NAM-U1
  • MXZ-SM48NAM-U1

MITSUBISHI-ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG2 MITSUBISHI-
ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG3

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.

|

Parts No.

|

Parts Name

| MXZ-SM36NAM-U1| MXZ-SM48NAM-U1|

Wiring Diagram Symbol

|

Remarks

---|---|---|---|---|---|---
1| R 0 1| R 6 5| 4 0 8| HEAT EXCHANGER| 1| 1|  |
2| T 7 W| A 1 0| 2 2 1| FAN MOTOR| 2| 2| MF1, MF2|
3| R 0 1| E 1 6| 1 1 5| PROPELLER FAN/D550| 2| 2|  |
4| R 0 1| E 1 6| 0 9 7| CAP NUT (MEC) M6| 2| 2|  |
5| R 0 1| A 5 7| 6 0 2| COMP FELT (TOP)| 1| 1|  |
6| T 7 W| B 0 4| 6 0 2| COMP FELT-B/ANB33FN| 1| 1|  |
7| R 0 1| U 0 0| 6 0 2| COMP FELT-U/ANB| 1| 1|  |
8| R 0 1| C 1 1| 5 1 0| LEAD ASSY COMP| 1| 1|  |
9| T 9 7| 4 7 7| 0 7 7| COMPRESSOR| 1| 1| MC| ANB33FNHMT

Includes RUBBER MOUNT

10| R 0 1| E 8 1| 4 4 0| ACCUMULATOR| 1| 1|  |
11| R 0 1| E 3 6| 2 0 1| THERMISTOR/SHELL| 1| 1| TH4 (Compressor)|
12| R 0 1| H 8 7| 2 0 2| THERMISTOR| 1| 1| TH3 (Outdoor Liquid Pipe)|
13| R 0 1| M 3 0| 2 0 2| THERMISTOR| 1| 1| TH2 (HIC Pipe)|
14| R 0 1| M 3 1| 2 0 2| THERMISTOR W| 1| 1| TH6 (Suction Pipe) TH7 (Ambient)| Combined Port
15| R 0 1| E 1 6| 4 9 0| OIL SEPARATOR| 1| 1|  |
16| R 0 1| E 0 2| 4 2 6| CT ASSY| 1| 1|  |
17| T 7 W| E 1 1| 4 2 8| SV1 ASSY| 1| 1| SV1|
18| T 7 W| E 9 1| 2 4 2| SOLENOID COIL (SV)| 1| 1| SV1| Includes SCREW
19| R 0 1| R 2 7| 4 0 1| LEV ASSY- A| 1| 1| LEV-A|
20| R 0 1| H R 1| 2 4 2| COIL (LEV)/XAP-5P WH| 1| 1| LEV-A|
21| T 7 W| B 0 7| 4 0 1| HIC & LEV-B ASSY| 1| 1| LEV-B|
22| R 0 1| H 5 8| 2 4 2| COIL (LEV)/XAP-5P RED| 1| 1| LEV-B|
23| T 7 W| E 1 5| 4 1 0| STOP VALVE ASSY-3/8F| 1| 1|  | 3/8
24| T 7 W| E 1 1| 4 1 1| BALL VALVE & STRAINER| 1| 1|  | 5/8
25| T 7 W| F 0 0| 2 4 2| SOLENOID COIL (21S4)| 1| 1| 21S4| Includes SCREW
26| R 0 1| E 4 0| 4 0 3| 4WAY VALVE| 1| 1| 21S4|
27| T 7 W| E 1 3| 4 1 3| CHARGE PLUG/LB54| 1| 1|  | Lo
28| R 0 1| E 1 2| 4 1 3| CHARGE PLUG/LB90| 1| 1|  | Hi
29| T 7 W| E 1 5| 2 0 8| H. P. SWITCH UL4.14MPA| 1| 1| 63H|
30| R 0 1| E 1 4| 2 0 8| H. P. SENSOR| 1| 1| 63HS|
31| R 0 1| E 0 4| 2 0 9| LOW PRESSURE SENSOR| 1| 1| 63LS|
32| R 0 1| E 5 6| 2 5 9| REACTOR| 3| 3| DCL|
33| R 0 1| E 1 4| 2 3 9| FUSE 6.3A 250V| 2| 2| F1, F2| 6.3 A 250 V
34| R 0 1| M 1 1| 3 5 0| CONTROLLER BOARD| 1| 1| MULTI.B.|
35| R 0 1| E 0 7| 3 1 1| M-NET POWER BOARD| 1| 1| M-NET P.B.|
36| R 0 1| M 0 5| 3 5 3| POWER BOARD| 1| 1| P.B.|
37| R 0 1| A 2 2| 3 7 1| HEAT SINK| 1| 1|  | Includes SCREWS
38| R 0 1| M 1 3| 2 0 2| THERMISTOR (HS)| 1| 1| TH8 (Heat Sink)|
39| T 7 W| 6 0 3| 2 4 6| T.B./L1.L2.GR| 1| 1| TB1| 3P (L1, L2, GR)
40| T 7 W| E 5 7| 7 1 6| T.B./B1.B2| 1| 1| TB1B| 2P (B1, B2)
41| R 0 1| E 2 7| 2 4 6| T.B./M1.M2.S| 2| 2| TB3, TB7| 3P (M1, M2, S)
42| R 0 1| E 2 0| 2 3 9| FUSE 20 A 250 V| 2| 2| FUSE1, 2| 20 A 250 V
43| R 0 1| 3 0 L| 2 4 1| FUSE HOLDER| 2| 2|  |

  • MXZ-SM60NAM-U1

MITSUBISHI-ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG4 MITSUBISHI-
ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG5

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.

|

Parts No.

|

Parts Name

|

MXZ-SM60NAM-U1

|

Wiring Diagram Symbol

|

Remarks

---|---|---|---|---|---
1| R 0 1| H 6 6| 4 0 8| HEAT EXCHANGER| 1|  |
2| T 7 W| A 1 2| 2 2 1| FAN MOTOR| 2| MF1, MF2|
3| R 0 1| E 1 6| 1 1 5| PROPELLER FAN/D550| 2|  |
4| R 0 1| E 1 6| 0 9 7| CAP NUT (MEC) M6| 2|  |
5| R 0 1| T 1 1| 6 0 2| COMP FELT- TOP/ANB| 1|  |
6| T 7 W| B 0 5| 6 0 2| COMP FELT-B/ANB52| 1|  |
7| R 0 1| U 0 0| 6 0 2| COMP FELT-U/ANB| 1|  |
8| R 0 1| C 1 2| 5 1 0| LEAD ASSY COMP| 1|  |
9| T 9 7| 4 7 9| 0 7 7| COMPRESSOR| 1| MC| ANB52FYDMT

Includes RUBBER MOUNT

10| R 0 1| H 6 7| 4 4 0| ACCUMULATOR| 1|  |
11| R 0 1| E 3 6| 2 0 1| THERMISTOR/SHELL| 1| TH4 (Compressor)|
12| R 0 1| H 8 7| 2 0 2| THERMISTOR| 1| TH3 (Outdoor Liquid Pipe)|
13| R 0 1| M 3 0| 2 0 2| THERMISTOR| 1| TH2 (HIC Pipe)|
14| R 0 1| M 3 1| 2 0 2| THERMISTOR W| 1| TH6 (Suction Pipe) TH7 (Ambient)| Combined Port
15| R 0 1| E 1 4| 4 9 0| OIL SEPARATOR| 1|  |
16| R 0 1| C 0 0| 4 2 6| CT ASSY| 1| |
17| T 7 W| E 1 2| 4 2 8| SV1 ASSY| 1| SV1|
18| T 7 W| E 9 1| 2 4 2| SOLENOID COIL (SV)| 1| SV1| Includes SCREW
19| T 7 W| H 6 1| 4 0 1| LEV ASSY-A/C- HIC| 1| LEV-A|
20| R 0 1| H 3 9| 2 4 2| COIL (LEV)/XAP-5P WH| 1| LEV-A|
21| T 7 W| B 0 8| 4 0 1| HIC & LEV-B ASSY| 1| LEV-B|
22| R 0 1| H 5 8| 2 4 2| COIL (LEV)/XAP-5P RED| 1| LEV-B|
23| T 7 W| E 1 6| 4 1 0| STOP VALVE ASSY-3/8F| 1|  | 3/8
24| T 7 W| E 1 3| 4 1 1| BALL VALVE & STRAINER| 1|  | 3/4
25| T 7 W| F 0 0| 2 4 2| SOLENOID COIL (21S4)| 1| 21S4| Includes SCREW
26| T 7 W| E 0 9| 4 0 3| 4WAY VALVE| 1| 21S4|
27| R 0 1| E 1 2| 4 1 3| CHARGE PLUG/LB90| 1|  | Lo
28| R 0 1| E 1 2| 4 1 3| CHARGE PLUG/LB90| 1|  | Hi
29| T 7 W| E 1 5| 2 0 8| H. P. SWITCH UL4.14MPA| 1| 63H|
30| R 0 1| E 1 4| 2 0 8| H. P. SENSOR| 1| 63HS|
31| R 0 1| E 0 4| 2 0 9| LOW PRESSURE SENSOR| 1| 63LS|
32| R 0 1| E 5 6| 2 5 9| REACTOR| 3| DCL|
33| R 0 1| E 1 4| 2 3 9| FUSE 6.3A 250V| 2| F1, F2| 6.3 A 250 V
34| T 7 W| M 2 9| 3 1 5| CONTROLLER BOARD| 1| MULTI.B.|
35| R 0 1| E 0 7| 3 1 1| M-NET POWER BOARD| 1| M-NET P.B.|
36| T 7 W| M 0 1| 3 2 3| POWER BOARD| 1| P.B.|
37| R 0 1| A 2 3| 3 7 1| HEAT SINK| 1|  | Includes SCREWS
38| R 0 1| M 1 6| 2 0 2| THERMISTOR (HS)| 1| TH8 (Heat Sink)|
39| T 7 W| 6 0 3| 2 4 6| T.B./L1.L2.GR| 1| TB1| 3P (L1, L2, GR)
40| T 7 W| E 5 7| 7 1 6| T.B./B1.B2| 1| TB1B| 2P (B1.B2)
41| R 0 1| E 2 7| 2 4 6| T.B./M1.M2.S| 2| TB3, TB7| 3P (M1, M2, S)
42| R 0 1| E 2 0| 2 3 9| FUSE 20 A 250 V| 2| FUSE1, 2| 20 A 250 V
43| R 0 1| 3 0 L| 2 4 1| FUSE HOLDER| 2|  |
44| T 7 W| E 3 9| 3 4 6| NOISE FILTER| 1| N.F.|

  • MXZ-SM36NAMHZ-U1
  • MXZ-SM42NAMHZ-U1
  • MXZ-SM48NAMHZ-U1

MITSUBISHI-ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG6 MITSUBISHI-
ELECTRIC-MXZ-SM36NAM-U1 -Multi-Zone-Ductless-Heat-Pump-Condenser-
FIG7

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.

|

Parts No.

|

Parts Name

|

MXZ-SM36NAMHZ-U1

|

MXZ-SM42NAMHZ-U1

|

MXZ-SM48NAMHZ-U1

|

Wiring Diagram Symbol

|

Remarks

---|---|---|---|---|---|---|---
1| R 0 1| R 6 5| 4 0 8| HEAT EXCHANGER| 1| 1| 1|  |
2| T 7 W| A 1 0| 2 2 1| FAN MOTOR| 2| 2| 2| MF1, MF2|
3| R 0 1| E 1 6| 1 1 5| PROPELLER FAN/D550| 2| 2| 2|  |
4| R 0 1| E 1 6| 0 9 7| CAP NUT (MEC) M6| 2| 2| 2|  |
5| R 0 1| A 5 7| 6 0 2| COMP FELT (TOP)| 1| 1| 1|  |
6| T 7 W| B 0 3| 6 0 2| COMP FELT-B/ANB33FJ| 1| 1| 1|  |
7| R 0 1| U 0 0| 6 0 2| COMP FELT-U/ANB| 1| 1| 1|  |
8| R 0 1| C 1 3| 5 1 0| LEAD ASSY COMP| 1| 1| 1|  |
9| T 9 7| 4 4 3| 0 7 7| COMPRESSOR| 1| 1| 1| MC| ANB33FJSMT

Includes RUBBER MOUNT

10| R 0 1| E 8 1| 4 4 0| ACCUMULATOR| 1| 1| 1|  |
11| R 0 1| E 3 6| 2 0 1| THERMISTOR/SHELL| 1| 1| 1| TH4 (Compressor)|
12| R 0 1| H 8 7| 2 0 2| THERMISTOR| 1| 1| 1| TH3 (Outdoor Liquid Pipe)|
13| R 0 1| M 3 0| 2 0 2| THERMISTOR| 1| 1| 1| TH2 (HIC Pipe)|
14| R 0 1| M 3 1| 2 0 2| THERMISTOR W| 1| 1| 1| TH6 (Suction Pipe) TH7 (Ambient)| Combined Port
15| R 0 1| E 1 6| 4 9 0| OIL SEPARATOR| 1| 1| 1|  |
16| R 0 1| E 0 2| 4 2 6| CT ASSY| 1| 1| 1|  |
17| T 7 W| E 1 1| 4 2 8| SV1 ASSY| 1| 1| 1| SV1|
18| T 7 W| E 9 1| 2 4 2| SOLENOID COIL (SV)| 1| 1| 1| SV1| Includes SCREW
19| R 0 1| R 2 7| 4 0 1| LEV ASSY- A| 1| 1| 1| LEV-A|
20| R 0 1| H R 1| 2 4 2| COIL (LEV)/XAP-5P WH| 1| 1| 1| LEV-A|
21| T 7 W| B 0 9| 4 0 1| HIC & LEV-B ASSY| 1| 1| 1| LEV-B|
22| R 0 1| H 5 8| 2 4 2| COIL (LEV)/XAP-5P RED| 1| 1| 1| LEV-B|
23| T 7 W| E 1 5| 4 1 0| STOP VALVE ASSY-3/8F| 1| 1| 1|  | 3/8
24| T 7 W| E 1 1| 4 1 1| BALL VALVE & STRAINER| 1| 1| 1|  | 5/8
25| T 7 W| F 0 0| 2 4 2| SOLENOID COIL (21S4)| 1| 1| 1| 21S4| Includes SCREW
26| R 0 1| E 4 0| 4 0 3| 4WAY VALVE| 1| 1| 1| 21S4|
27| T 7 W| E 1 3| 4 1 3| CHARGE PLUG/LB54| 1| 1| 1|  | Lo
28| R 0 1| E 1 2| 4 1 3| CHARGE PLUG/LB90| 1| 1| 1|  | Hi
29| T 7 W| E 1 5| 2 0 8| H. P. SWITCH UL4.14MPA| 1| 1| 1| 63H|
30| R 0 1| E 1 4| 2 0 8| H. P. SENSOR| 1| 1| 1| 63HS|
31| R 0 1| E 0 4| 2 0 9| LOW PRESSURE SENSOR| 1| 1| 1| 63LS|
32| R 0 1| E 5 6| 2 5 9| REACTOR| 3| 3| 3| DCL|
33| R 0 1| E 1 4| 2 3 9| FUSE 6.3A 250V| 2| 2| 2| F1, F2| 6.3 A 250 V
34| R 0 1| M 1 1| 3 5 0| CONTROLLER BOARD| 1| 1| 1| MULTI.B.|
35| R 0 1| E 0 7| 3 1 1| M-NET POWER BOARD| 1| 1| 1| M-NET P.B.|
36| T 7 W| M 0 1| 3 2 3| POWER BOARD| 1| 1| 1| P.B.|
37| R 0 1| A 2 3| 3 7 1| HEAT SINK| 1| 1| 1|  | Includes SCREWS
38| R 0 1| M 1 6| 2 0 2| THERMISTOR (HS)| 1| 1| 1| TH8 (Heat Sink)|
39| T 7 W| 6 0 3| 2 4 6| T.B./L1.L2.GR| 1| 1| 1| TB1| 3P (L1, L2, GR)
40| T 7 W| E 5 7| 7 1 6| T.B./B1.B2| 1| 1| 1| TB1B| 2P (B1, B2)
41| R 0 1| E 2 7| 2 4 6| T.B./M1.M2.S| 2| 2| 2| TB3, TB7| 3P (M1, M2, S)
42| R 0 1| E 2 0| 2 3 9| FUSE 20 A 250 V| 2| 2| 2| FUSE1, 2| 20 A 250 V
43| R 0 1| 3 0 L| 2 4 1| FUSE HOLDER| 2| 2| 2|  |
44| T 7 W| E 3 9| 3 4 6| NOISE FILTER| 1| 1| 1| N.F.|
45| T 7 W| E 7 2| 2 4 2| SOLENOID COIL (SV)| 1| 1| 1| SV2| Includes SCREW
46| T 7 W| B 0 3| 3 0 0| BASE HEATER| 1| 1| 1| BH, THP|

OPTIONAL PARTS

Parts name Parts No.
AIR OUTLET GUIDE*1 PAC-SH96SG-E
DRAIN SOCKET *2 PAC-SG61DS-E
CENTRALIZED DRAIN PAN*2 PAC-SH97DP-E
DEFROST HEATER PAC-SJ20BH-E
2 BRANCH PIPE (Joint) CMY-Y62-G-E
4 BRANCH PIPE (Joint) CMY-Y64-G-E
8 BRANCH PIPE (Joint) CMY-Y68-G-E

JOINT PIPE (Unit → Extension pipe)

| MAC-A454JP-E (ø3/8 [9.52] → ø1/2 [12.7])
PAC-SG76RJ-E (ø3/8 [9.52] → ø5/8 [15.88])
PAC-SG75RJ-E (ø5/8 [15.88] → ø3/4 [19.05])*3
PAC-493PI (ø1/4 [6.35] → ø3/8 [9.52])
MAC-A456JP-E (ø1/2 [12.7] → ø5/8 [15.88])
EXTERNAL LEV BOX| PAC-SG95LE-E

  1. Need 2 pieces
  2. Only for MXZ-SM36/48/60NAM model It can not be used with DEFROST HEATER.
  3. Only for MXZ-SM60

HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

©Copyright 2021 MITSUBISHI ELECTRIC CORPORATION
Issued: Jul. 2022 No. OCB789 REVISED EDITION-A
Published: Nov. 2021 No. OCB789
Made in Japan

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals