WARNING
RISK OF ELECTRIC SHOCK
- Turn power off before installation, inspection, cleaning or removal. And follow appropriate lock out/tag out safety procedure.
- Properly ground electrical enclosure.
- Follow all National Electric Codes (NEC) and local codes.
- This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- The installation and associated structures are subject to approval by the authority having jurisdiction.
- Use only with components identified in this document.
- Suitable for dry, damp, and wet locations; Do not immerse any component.
- Wear suitable Personal Protective Equipment (PPE) during installation/maintenance. Highly recommend safety glasses, helmet and leather glove for luminaire mounting.
- Luminaire design for Greenhouse only.
Suitable for operation in an ambient temperature between 32°F (0°C) and
104°F (40°C).
A mechanical ventilation or cooling system is required to maintain the
temperature within the growing space below 104°F (40°C) when the light module
is in operation.
Save These Instructions
-
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
-
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the in-struction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. -
This Class [A] RFLD complies with the Canadian standard ICES-005. /CeDEFR de la classe [A] est conforme à la NMB-005 du Canada.
Specifications
Driver Specifications
SKU
| ****
Description
| ****
Weight
| Driver Input Ratings
Voltage| Current| Power Factor
93064969| GEPSC070-210G-ADFNA| 1.5kg (3.3 lbs)| 120/208/240 VAC, 50/60 Hz|
2.5/1.6/1.2 A| > 0.9
93117154| GEPSC070-210G-AGJNA| 1.5kg (3.3 lbs)| 277V-480V| 0.9A – 0.5A| >0.9
Light Module Specifications
SKU
| ****
Description
| ****
Detailed description
| ****
Weight
| LED Module Input Ratings
Voltage| Current| Power
93067254| GEHR3007M-N120CH-PPR-1| Top Lighting Light module, Purple Type “R”|
1.65kg (3.64lbs)| 260 VDC| 0.7A| 182W
93067255| GEHR3007M-N120CH-PPB-1| Top Lighting Light module, Purple Type “B”|
255 VDC| 0.7A| 179W
Inter-Connection Cables Specification
SKU| Description| Detailed description| Weight
93067607| GECA30A14-AA06B| Inter-Connection cable 6 feet, UL| 0.32kg (0.7 lbs)
93067608| GECA30A14-AA12B| Inter-Connection cable 12 feet, UL| 0.60kg (1.3
lbs)
Accessories
SKU| Description| Components
TBD| GEHAK-KN-NA-N0| 2 x 1-5/8” square driver brackets and 2 x 1’ support
cables
- Compression tool and stop sleeves
- Cable cutters
- Suspension cable
- Turnbuckle
- Wire clamp
Components Supplied
- Top Light module (93067254, 93067255)
- Driver (93064969 or 93117154)
- Optional: Inter-connection cable (93067607, 93067608)
Important Guidelines
- Minimum 4 inch distance from lighting equipment to any combustible material.
- Minimum 4 inch distance between light module and driver or other light module.
- The light module shall be installed lens down with a minimum 5 inch distance to anything below.
- For safe operation, and to maximize the longevity of the luminaire; ensure that the light module and driver are clean and free of dirt, dust, oil, or any other debris prior to operation. Do not apply any kind of film on the lens or otherwise cover the driver or light engine in any way.
- Cables shall not be concealed or extended through a wall, floor, ceiling, or other parts of the building structure; located above a suspended ceiling or dropped ceiling; permanently affixed to the building structure.
- Cables shall be routed so that they are not subject to strain and are protected from physical damage; visible over their entire length; and used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions.
- Installer is responsible for driver bank design and construction.
- Driver bank plate shall be made of non-combustible material.
- Installer must select suspension cable able to support 5 times the weight of Light module.
- Maximum cumulative Inter-connection cable length is 24 feet.
ATTENTION
- Suspension cable diameter must be between 0.10 inch (2.5mm) and 0.16 inch (4mm).
- Selection of proper common hardware with good quality is the responsibility of installer.
- Consider using material having proper strength and corrosion resistance for the environment.
Installation Option A: Hang Luminaires on Horizontal Cable
Option A Overview
Option A Installation Steps
ATTENTION
- Installer is responsible for suspension cable assembly.
- Test cable with at least 5x luminaires weight.
- a: Loop one end of cable around a structural member and secure with a stop sleeve.
1. b: Loop one end of cable around a structural member and secure with a wire clamp.
- Loosen the turnbuckle and secure it to a structural member. Secure opposite end of cable to turnbuckle.
Tighten turnbuckle to reduce slack in cable.
- Secure upper end of support cables to a structural member at intervals of approximately 16 ft. Secure lower end to horizontal cable. See Installation
Overview diagram above for reference
- Hang light engines on horizontal cable and position them evenly along cable.
Connect light engines to drivers directly or by using inter-connection cables (see next section for details).
Installation Option B: Hang Luminaires on Vertical Cables
Option B Overview
Option B Installation Steps
ATTENTION
- Installer is responsible for suspension cable assembly.
- Test cable with at least 5x luminaires weight.
- Loop two cables around a structural member and secure ends with stop sleeves or wire clamps.
- Loop opposite end of cables through top light hangers and secure with stop sleeves or wire clamps.
- Connect light engines to drivers directly or by using inter-connection cables (see next section for details).
Electrical Connections
- Connect driver(s) to junction box.
-
Mate male connector from module with female connector from DC output of driver.
Secure blue lock nut by turning counterclockwise until tight ensuring water tight seal and good connection. -
Option A: Connect driver output directly to luminaire.
Option B: Connect driver output to luminaire using inter-connection cable. -
Connect the green wire to the incoming ground conductor. Connect the black wire to Line 1 and white wires to the Neutral or Line 2 of the incoming AC line.
Connection Schematic
WARNING
- RISK OF ELECTRICAL SHOCK: Turn power OFF before inspection, installation or removal.
- Ambient temperature surrounding each driver must be lower than 104°F (40°C).
Connect the light engine to driver prior to powering the driver. Plug together
cables between light engine and driver. For longer distances between light
engine and driver, use an inter-connection cable (6 or 12 feet long) to
complete connection.
RISK GROUP 2 – CAUTION / ATTENTION
Possibly hazardous optical radiation emitted from this product. Do not stare
at operating lamp. May be harmful to the eyes.
DISPOSAL
- Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.
- Conforms to the following standards:
CONTACT
- Visit www.LED.com
- Call us today! 1-888-MY-GE-LED
- Email us: horticulture.info@ge.com
- For more info scan qr code given below
ABOUT COMPANY
GE and the GE Monogram are trademarks of the General Electric Company and are
used under license. Information provided is subject to change without notice.
All values are design or typical values when measured under laboratory
conditions, and GE makes no warranty or guarantee, express or implied, that
such performance will be obtained under end-use conditions. © 2019 GE Current,
a Daintree company.
www.LED.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>