CARRO NYDE241123 Tower Cool Mist Humidifier User Manual

June 2, 2024
CARRO

CARRO NYDE241123 Tower Cool Mist Humidifier

READ AND SAVE THESE INSTRUCTIONS
Read This Manual
Inside you’ll find many helpful hints on how to use and maintain your appliance properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your appliance. You’ll find many answers to common problems in the troubleshooting tips – you should be able to fix most of them quickly before calling customer service. These instructions may not cover every possible condition, so attention to safety details is required when operating and maintaining this product.

SAFETY PRECAUTIONS

To prevent injury to the user or other people and property damage, the instructions shown here must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The different levels of risk is shown by the following indications.

  • WARNING This symbol indicates a hazardous situation that, if not avoided, could result in death or serious injury.
  • CAUTION This symbol indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury.
  • NOTICE This symbol addresses practices not related to physical injury.

IMPORTANT INSTRUCTIONS

  • In the case of power up, do not plug or unplug the power cord with wet hands to avoid electric shock;
  • Do not force the water tank to work in the case of no water;
  • Do not add any additives not produced or supervised by the company to the water tank;
  • Do not put or place anything or pets into the water tank;
  • Do not add water to the atomization outlet;
  • When the humidifier is working, do not touch the water in the water tank or the parts sink in the water;
  • Do not cover the atomization outlet, and please keep it clear above the outlet;
  • Do not replace the power cord without authorization, connect the power cord halfway or use other appliances in parallel;
  • Do not place the appliance near the water source;
  • Do not disassemble, modify or repair internal parts without authorization;
  • Do not climb or sit on the appliance;
  • Do not store flammable or explosive materials around the humidifier;
  • Do not place it near a heat source;
  • Do not directly flush the humidifier with water;
  • Do not turn off the humidifier by unplugging the power cord directly;
  • Do not use volatile oil, alcohol, thinner, etc. to clean the machine, otherwise, the product may be damaged;
  • Please keep a distance of more than 12 inches between the humidifier and other products;
  • Do not modify the use and function of the product without permission;
  • Do not place the water container on the live product, the water immersing in the product will weaken the electrical insulation, resulting in Electric shock, fire, etc;
  • When the power is turned off in low-temperature weather, the water must be drained.

CAUTION

Matters that may cause minor injury or property damage. Please unplug the power plug when filling and cleaning. The power supply must be within the specified voltage range of the product.

  • Please use purified water for humidification;
  • Please do not use a damaged or worn power cord; Do not replace the power cord without authorization. If the power cord is damaged, it must be replaced by the manufacturer, its service department or professional from similar department to avoid danger.
  • The power must be cut off in thunderstorms;
  • When an abnormal phenomenon (like a burnt smell) occurs, the operation must be stopped and the power supply is cut off.
  • Please unplug the power cord and clean the water tank, when the appliance is not used for a long time;
  • To avoid bacterial growth, please always change the water in the water tank.
  • When the appliance is moved, please unplug the power cord to keep the water tank stable and to prevent the water from overflowing in the water tank;
  • If the appliance is tilted when filled with water, be sure to unplug the power cord immediately and send it for inspection.
  •  Suitable temperature for this product: 41°F -104°F; relative humidity: less than 80% RH (please fill purified water with water temperature below 104°F).

RULES FOR SAFE OPERATION

WARNING

  • Please be sure to unplug the power cord before filling the water.
  • The level of the water added shall not be higher than the highest water level;
  • Please do not add the water in the atomization outlet when the water is added;
  • Please do not add additives like essential oil, perfume, drugs, etc. to the water.
  • Please use the purified water below 104°F(Do not use distilled water).

ASSEMBLY

This humidifier is pre-assembled in the factory.

SPECIFICATIONS

NOTICE

  • The following are the design parameters of PH-805-24 the measured parameters are subject to the product;
  • The humidification amount will vary, depending on the temperature and humidity in the room.
  • The actual humidification amount is not less than 90% the standard 390mL/h.
Model Rated voltage Rated frequency Rated power Noise Volume of tank

PH-805-24

| 120V ~|

60Hz

|

24W

|

38dB

|

2.11Gal

PARTS AND FEATURES

NOTICE

  • The pictures in the Manual are for reference only, and the actual product in the packing box shall prevail.
  • The product appearance and function vary with the model; Please be subject to the real product, with optional reading of the respective function description.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-1

INSTRUCTION FOR USE

Two methods for water filing
Method A
Fill the water tank directly through the main unit cover. Please use purified water. Please do not add water in the atomization outlet.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-2

Method B
Lift the main unit of the humidifier up and fill purified water directly from top of the water tank.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-3

OPERATION INSTRUCTIONS

NOTICE

  • If the indoor temperature is too low or the humidity is too high, and the mist cannot be fully diffused, it is recommended to reduce the volume of water mist.
  • When the humidity setting is lower than the current humidity, the atomizing mist will stop within two minutes. In the working state, if there is no operation for more than 1 minute, the operation screen will automatically enter the light-off sleep mode The level of atomization remains unchanged.

Control Panel

Buttons Operation

On/Off

| 1.  Shortly press this button to enter the on/idle state.

2. In the on/idle state, press and hold for 3 seconds till hearing “be- ep”, the WIFI signal on the screen will blink and enter the CARRO HOME APP connection mode.

Atomization adjustment

| Under working conditions, the humidity and atomization amount can be set to three levels (small, medium and large). Press and hold till hear “beep” to enter sleep mode, the display light will be turned off, and the atomization amount level automatically switch to level 1 (small).

Timing button

| 1. Shortly press in the working conditions, and you can cycle to set the timer function. The timer setting can be 0h→1h→ 2h→4h→8h→0h.

2.  In the process of setting, the setting timer time will be

displayed first, and then if you do not operate, the timer will flash 3 times and then switch to display the humidity of the current environment.

3. The timer time displays in a countdown way. After setting the timer, if you press the timer button again, the operation screen will display the remaining time before shutdown, and then press the timer button again to reset the timer.

4.  After the timer is turned on, press and hold the timer button for 3 seconds to exit the timer setting state.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-
FIG-32CLEANING AND MAINTENANCE

WARNING

  • IMPORTANT TIP : DO NOT leave the humidifier plugged in for prolonged periods (i.e. several days or more) without use.
  • This causes premature failure of the circuitry. When the humidifier is not in use, press the control button until the light goes off, then UNPLUG it. Before cleaning or descaling, be sure to unplug the power cord.
  • Do not use abrasive, corrosive, or flammable cleaners (such as bleach or alcohol) to clean any part of the humidifier.
  • The humidifier must regularly clean the scale and debris in the water tank and sink. It is recommended to clean it once a week.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-12

Cleaning the outer casing
Wipe and clean the surface of the whole machine with a slightly damp soft cloth. In case of stubborn stains, add a small drop of detergent to clean it, and then wipe the detergent away.
Warning: Do not use a dripping soft cloth to clean the outer casing, or rinse it with a shower.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-13

Tank cleaning
First take out the main unit cover, then lift the main unit upwards, shake the main unit slightly, so that the water in the mist guiding tube flows back to the water tank, put the main unit aside, then pour clean water into the water tank, and add an appropriate amount of detergent for cleaning. Use a clean cloth to dry the inside and outside of the water tank.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-14

Cleaning the inside & outside of the mist guiding tube, and the atomizing head

  1.  Rotate counterclockwise to unscrew connecting hose of the main unit and the atomizing head as shown in Fig 1.
  2. Hold the main unit with one hand, press the spring switch of the mist guiding tube with the other hand at the same time as shown in Fig 2, and remove the main unit in Fig 3.
  3. Rotate the lower cover of the tube clockwise to remove the cover, and then take out the atomizing head assembly as shown in Fig 4.
  4. Clean the dirt inside the tube with a long-handled soft brush(not included) as shown in Fig 5 , and then wash the tube in the sink.CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-15
  5. Use a screwdriver(not included) to poke the small hole in the back of the atomizing head assembly, take out the atomizing head for cleaning as shown in Fig 6 , and wipe the centre of it with a damp soft cloth.
  6. When cleaning the components of the float, first loosen the set screw, rotate the upper shell of the float clockwise and take it out, and then take out the foam of the float as shown in Fig 7.
  7. Wipe the upper shell of the float with a clean damp cloth, use a soft brush (not included) to clean the lower part of the float as shown in Fig 8 , and then put it in the sink to clean it.

NOTICE

The foam of the float in Fig 7 is an important part of atomizing head assembly, DO NOT mistakenly discard it as part of the packaging.

Mist tube assembly installation

  • Install the atomizing head on the float assembly.
  • Put the main unit on the table, and align the mist guiding tube with its slot it for installation.
  • Install the float assembly into the mist tube.(The upper shell of the float faces the direction of the main unit.)
  • Rotate the lower cover of the tube clockwise.
  • Connect the atomizing head hose to the main unit.

SERVICE GUIDE

Fault Handling

NOTICE

If the humidifier does not work properly after the following suggestions, please contact the customer service centre or local service station.

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-33

WARRANTY

ONE (1) YEAR LIMITED WARRANTY

WHAT IS COVERED
This warranty covers any manufacturing defect for the humidifier, with the exceptions stated below.
HOW T0 GET SERVICE
Please keep your receipt or other documents so that we may process your warranty request. To obtain service, contact by E-mail: cs@carrohome.com Tel:888-253-2374.
HOW LONG COVERAGE LASTS
This warranty runs for one(1) year from the date of purchase.
WHAT IS NOT COVERED
The warranty applies only to the original Purchaser within the USA and does not cover

  • Wear and tear
  • Stains
  • Misuse or improper maintenance
  • Alteration or repair by unauthorized representatives
  • Damage resulting from transit or handling
  • Damage caused by improper placement (such as placing products near- heating pipes, etc.)
  • Deterioration caused by Force Majeure (unforeseeable circumstances, such as fire, earthquake, flood, lightning and other natural disasters, environmen- tal pollution )
  • Any humidifier outside of the contiguous 48 states
  • Any claim made outside of the warranty period

APP Control Connection:

  1.  First, download the free Carro Home app from the App Store or Google Play or scan the QR Code as below. To connect the device to the app must turn on WIFL and Bluetooth on your phone.
    Note: This humidifier needs to use 2.4Ghz wifi to work when you connecting the device, and after connecting it can use the 5Ghz or 2.4Ghz.

  2. Open the Carro Home app to create your account. The account with “Carro Home” can be registered through E-mail or Mobile phone.

  3. Connect the device to the Carro Home APP(The WIFI signal on the screen is blinking):

  4. Press the “+” button, select “Smart Home Appliances” on the sidebar menu on the next page,then select “Humidifier”.

  5. Connect to your home WIFI (Only for 2.4 GHz).

  6. Press the Smart Humidifier “+” button to wait for the connection to complete.
    Note: Press and hold the ” ” till hear “beep”, the WIFI will blink and enter the CARRO HOME APP connection mode.

  7. Connect the device to the Alexa:

  8. Make sure you have connected the device to the app and working normally.

  9. Open the Alexa app, and go to the skill to search “Carro Home” skill.

  10. Link the skill, log in with your Carro Home app account and password, and then authorize and connect with the Carro Home app.

  11. hen the Alexa will find out the device automatically

  12. Connect the device to the Google Home

  13. Make sure you have connected the device to the app and working normally.

  14. Open the Google Home app, Set up a device, and choose “Works with Google”.

  15. Search “Carro Home”, log in with your Carro Home app account and password, and then authorize and connect with the Carro Home app.

  16. Then the Google Assistant will find the device automatically

  17. Connect the device to the Siri shortcuts

  18. Make sure you have connected the device to the app and working functionally.

  19. Tap “Smart” on the main menu.

  20. Tap “+” button.

  21. Tap “Launch Tap To Run”.

  22. Tap “Run the device”.

  23. Choose the device you want to control by Siri.

  24. Select the function you want to control by Siri.

  25. Then save it.

  26.  Add to Siri, choose the scene you just made, Add to Siri.

  27. Enter the sentence you want to say to make the device work, Add it to Siri

Carro Home App Connection Guide

  1. Download & Install the Carro Home App
    Scan the QR code on the left and download the Carro Home App. To connect the device to the App must turn on WIFI and Bluetooth on your phone.

  2. Register & Log In
    Open the Carro Home App to create your account. The account with “Carro Home” can be registered through E-mail or Mobile phone.

  3. Add the Device

  4. Tap the “Add Device” button to add the device.

  5. Select “Smart Home Appliances” on the sidebar menu on the next page, then select “Humidifier”.
    Note: Your device may be automatically searched.
    Note: Press and hold the ” ” on the device control panel till hear a “beep”, the WIFI will blink and enter the Carro Home App connection mode.

  6. Sign into your WIFI network (Only for 2.4 GHz).

  7. Please turn on the device and confirm that indicator is blinking. For specific operations, please refer to the instructions on the App.

  8. Wait for the connection to complete. For specific operations, please refer to the instructions on the App.

  9. If the connection fails, please refer to the instructions on the App to check and retry.

Note:

  1. To connect the device to the App must turn on WIFI and Bluetooth on your phone.
  2. This humidifier needs to use 2.4Ghz WIFI to work when you connecting the device, and after connecting it can use the 5Ghz or 2.4Ghz.
  3. Make sure the WIFI network is stable.
  4. Make sure that the device, the phone and the router are close to each other.
  5. Check whether the WIFI name, password, etc have been modified. If so, reset the device and add it again.
  6. With product technical updates, the content of the Carro Home App may be changed, please refer to the guide displayed on the App.

Humidifier APP Operation

CARRO-NYDE241123-Tower-Cool-Mist-Humidifier-FIG-30

CONTACT

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CARRO User Manuals

Related Manuals