Lumineux 4ft 20W Olton Academic Batten Dual Wattage Instruction Manual

May 15, 2024
Lumineux

Lumineux 4ft 20W Olton Academic Batten Dual Wattage Instruction Manual

READ THESE INSTRUCTIONS THOROUGHLY BEFORE  INSTALLATION KEEP

THESEINSTRUCTIONS FOR FUTURE REFERENCE.

MPORTANT:
This product must be installed by a qualifi ed electrician or competent person, and in accordance with current building and IET wiring regulations.

BOX CONTENTS

This lighting fi xture has been properly packed to avoid damage during transit. Before commencing with the installation carefully inspect the luminaire to confi rm there is no damage. DO NOT INSTALL if any damage has occurred to the fi xture or any of its components.

  • Light Fitting
  • Instruction Manual
  • Fixing Kit

TOOLS REQUIRED

  • Drill

  • Screwdriver

  • Cable

INSTALLATION INSTRUCTIONS

  1. INSTALLATION INSTRUCTIONS

        1. Internal terminal block electrical connection wiring
  2. INSTALLATION INSTRUCTIONS

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION.

WARNING: Risk of electric shock! Isolate the mains power before proceeding.

  • Turn off the mains power before performing inspections, installation, or removal
  • Verify that the supply voltage is correct by comparing it with the luminaire label information
  • It is the installers responsibility to ensure installation is suitable for the total load of the luminaire(s). The supply cable, fuses/circuit brakers must be correctly rated for the electrical load and considering for any transient inrush currents that may occur
  • Do not perform insulation strength or resistance tests on installed luminarie(s) connected
  1. Disconnect mains supply, detach diffuser by unscrewing both screws ate each end cap.
  2. Unclip diffuser from base.
  3. Secure base to your desired location using adequate wall plugs and screws.
  4. Choose required entry point to feed cable through and using grommet provided.
  5. Wire as per diagram (5). Select preferred wattage. Note if you have purchased an emergency version (M3), please connect battery.
  6. Clip diffuser back to base and using same screws, secure to base at each end. Re-Connect mains supply

DISPOSAL

Disassemble instructions for end of life disposal available on website.

Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE), which means the product should not be disposed of as normal household waste. Please recycle where facilities exist or check with your Local Authority. RoHS – All components and materials used in this product are RoHS 2002/95/EC compliant.

Specifications may change from time to time. The information contained in this leaflet is for guidance only and should not be considered as always accurate and should be treated as not representative.

WARRANTY

This luminaire is warranted for a period of 5 years from the date of purchase**. The backup battery pack in the emergency version is warranted for a period of 24 months. The warranty could be invalidated should the light fitting not be installed according to these instructions, outside the scope of the specification or the product has been altered or tampered with in any way. Please see website for terms and conditions.

PRODUCT TEMP SPECIFICATION

Standard :  0º to +45ºC
Emergency: 0º to +25ºC
Revision 2.0: – MARCH 2023

OLTON ACADEMIC BATTEN DIMENSIONS

Part No.                     Description| Watts| L (mm)| W (mm)| H (mm)| Weight
---|---|---|---|---|---
430817         4ft Dual Wattage| 20W / 38W| 1190| 203| 83| 2.3Kg
430818         5ft Dual Wattage| 30W / 58W| 1490| 203| 83| 3.2Kg

MICROWAVE SENSOR SETTINGS

Detection Range: Hold time and daylight sensor can be set by using DIP switches on the sensor. Note that reducing the detection area will reduce the sensitivity.

Hold Time : Refers to the time period the lamp remains at 100% illumination after no motion is detected.

Daylight Sensor
: The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold. The settings are as shown.

STANDARD ON/OFF SENSOR

DETECTION AREA

| 1| 2| 3|
---|---|---|---|---
I| ON| ON| ON| 100%
II| | ON| ON| 75%
III| ON| | ON| 50%
IV| –| –| ON| 25%
V| –| –| –| 10%

HOLD TIME

| 4| 5| 6|
---|---|---|---|---
I| ON| ON| ON| 5S
II| | ON| ON| 30S
III| ON| | ON| 90S
IV| | | ON| 31Vin
V| ON| ON| | 20Min
VI| | | | 30Min

DAYLIGHT SENSOR

| 7| 8| 9|
---|---|---|---|---
I| ON| ON| ON| 2Lux
II| ON| ON| | 1 OLux
III| | ON| | 25Lux
IV| ON| | | 50Lux
V| –| –| –| Disable
Installation Engineers Contact Details:| Luminaire Reference / Location
---|---
Name:| Tel:|

| | | ROUTINE TEST RECORD| |
---|---|---|---|---|---
Type Test| Year| 1| Year 2| Year 3| Year 4| Year 5
| Signed| Date| Signed| Date| Signed| Date| Signed| Date| Signed| Date
Functional 1| | | | | | | | | |
Functional 2| | | | | | | | | |
Functional 3| | | | | | | | | |
Functional 4| | | | | | | | | |
Functional 5| | | | | | | | | |
Functional 6| | | | | | | | | |
Functional 7| | | | | | | | | |
Functional 8| | | | | | | | | |
Functional 9| | | | | | | | | |
Functional 10| | | | | | | | | |
Functional 11| | | | | | | | | |
3hr Duration 12| | | | | | | | | |

Please see our website for more detailed information on warranty.

Wiring instructions for units equipped an with EMERGENCY function

Emergency lighting luminaries must be installed and maintained in accordance with the emergency lighting standard BS 5266-1

  1. Connect incoming earth cable to ‘Earth’ terminal on connector block.
  2. Connect incoming neutral cable to ‘Neutral’ terminal on connector block.
  3. For the emergency unit to work correctly, please ensure that an uninterrupted permanent live feed is present and is connected directly to the ‘Permanent Live’ terminal of the mains terminal block. Please ensure there are no switches, PIRs etc within the permanent live feed, constant switching of the emergency pack could result in premature battery failure.
  4. Connect incoming switched live cable to the terminal marked “Switched Live

” NOTE: If there is no switch live feed and the unit has a microwave sensor, simply bridge across from the “Permanent Live” to the Switch Live” on the mains terminal block.

  1. There should be a loose flying lead connected to the battery. This needs to be attached to the flying lead from the emergency control unit.
  2. Following power up the green LED indicator should illuminate to indicate charging. If power to the unit is disrupted or isolated, the unit indicating green LED will switch off, triggering the emergency LEDs to illuminate.
  3. Please allow 24 hours charge before first emergency test.

EMERGENCY FITTINGS ONLY. EARTH CONNECTION REQUIRED.

L – LIVE (SW) = Brown
– EARTH = Green/Yellow
N – NEUTRAL = Blue
L1 – PERMANENT LIVE (PL) = Black

Warning Instructions
Warning Instructions

Company Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lumineux User Manuals

Related Manuals