Lumineux Wraysbury Plus 600×600 Panels Range Instruction Manual
- June 9, 2024
- Lumineux
Table of Contents
28W Panel Wraysbury 600 x 600
UGR Panel
Instruction Manual
READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
IMPORTANT:
This product must be installed by a qualifi ed electrician or competent person,
and in accordance with current building and IET wiring regulations.
**BOX CONTENTS
**
This lighting fi xture has been properly packed to avoid damage during
transit. Before commencing with the installation carefully inspect the
luminaire to confi rm there is no
damage. DO NOT INSTALL if any damage has occurred to the fi xture or any of
its components:
- Light Fitting
- Instruction Manual
- LED Driver
- Loch Connector
TOOLS REQUIRED
- Cable
INSTALLATION INSTRUCTIONS
Wraysbury
Panel
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION.
WARNING: Risk of electric shock! Isolate the mains power before
proceeding.
- Turn off the mains power before performing inspections, installation, or removal
- Verify that the supply voltage is correct by comparing it with the luminaire label information
- It is the installers responsibility to ensure installation is suitable for the total load of the luminaire(s). The supply cable, fuses/circuit brakers must be correctly rated for the electrical load and considering for any transient inrush currents that may occur
- Do not perform insulation strength or resistance tests on installed luminaire(s) connected
- Isolate the circuit
- Connect the driver cable to the mains as per image (1). (Terminal block not included). For emergency, see overleaf.
- Connect the LED driver to the panel using the Twist-N-Lock jack connector
- Fit the panel into desired location
- Re-connect the mains supply
DISPOSAL
The light source of this unit is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced.
Disassemble instructions for end of life disposal available on website.
Disposal of Electronic Equipment WEEE Directive 2002/96/EC This product falls
within the scope of the Waste Electrical & Electronic Equipment Directive
(WEEE), which means the product should not be disposed of as normal household
waste. Please recycle where facilities exist or check with your Local
Authority. RoHS – All components and materials used in this product are RoHS
2002/95/EC compliant.
Specifications may change from time to time. The information contained in this
leaflet is for guidance only and should not be considered as always accurate
and should be
treated as not representative.
WARRANTY
This luminaire is warranted for a period of 5 years from the date of purchase**. The backup battery pack in the emergency version is warranted for a period of 24 months. The warranty could be invalidated should the light fitting not be installed according to these instructions, outside the scope of the specification or the product has been altered or tampered with in any way. Please see website for terms and conditions.
PRODUCT TEMP SPECIFICATION
Standard | 0 to +40ºC |
---|---|
Emergency | 0 to +30ºC |
WRAYSBURY DIMENSIONS
Part No.| Description| Watts| L (mm)| W (mm)| H
(mm)| Weight
---|---|---|---|---|---|---
430118| Wraysbury 600 x 600
UGR TP(a) – 4000K| 28W| 595| 595| 28| 2.17Kg
430119| Wraysbury 600 x 600
UGR TP(a) – 6000K| 28W| 595| 595| 28| 2.17Kg
Installation Engineers Contact Details: | Luminaire Reference / Location |
---|---|
Name: | Tel: |
Luminaire Details: | Full Recharge Duration 24 Hours Emergency |
Hours | Lamp Type LED |
--- | --- |
Type Test | Year 1 |
5
---|---|---|---|---|---
| Signed| Date| Signed| Date| Signed| Date|
Signed| Date| Signed| Date**
Functional 1| | | | | | | | | |
Functional 2| | | | | | | | | |
Functional 3| | | | | | | | | |
Functional 4| | | | | | | | | |
Functional 5| | | | | | | | | |
Functional 6| | | | | | | | | |
Functional 7| | | | | | | | | |
Functional 8| | | | | | | | | |
Functional 9| | | | | | | | | |
Functional 10| | | | | | | | | |
Functional 11| | | | | | | | | |
3hr Duration 12| | | | | | | | | |
** Please see our website for more detailed information on warranty.
Wiring instructions for units equipped an with EMERGENCY function
Emergency lighting luminaries must be installed and maintained in accordance
with the emergency lighting standard BS 5266-1
- The installation of an emergency fitting MUST BE CONNECTED AS SHOWN in diagrams below.
- For the emergency unit to operate correctly the permanent live feed must not be interrupted. Note: Ensure no lighting controls are on the permanent Live feed, such as PIR’s or SWITCHES, failing to observe this will reduce the batteries lifetime of the emergency pack considerably.
- After switching on an emergency equipped unit, the LED indicator should illuminate this is to indicate battery charging.
- Should power to an emergency equipped unit be disrupted or isolated, the indicating LED will switch off, triggering the emergency function illuminating the LED’s
- The backup battery must be charged for 24 hours before a full duration test.
If the LED Driver & Downlight jack leads do not match the gender as in diagram, please use provided gender changing leads to correct.
Self-Test EMERGENCY function
The self-test version of emergency is fitted with control gear that will carry out periodic functional tests every 1 month and full duration test every 12 months.
Status | Description |
---|---|
Standby, System OK | Mains Operation, |
battery is charged
Function test underway| Function test underway
Duration test underway| Duration test underway
Lamp failure| Open Circuit or Short Circuit or LED failure
Battery capacity failure| Battery failed duration test
Battery fault| Incorrect battery voltage or Short Circuit or Open Circuit
Battery Operation| Emergency mode: Mains disconnected or Mains failure
This product contains a light source of energy efficiency Class E.
Technical Helpline: +44 (0)1507 328031
www.lumineux.co.uk
Munby Business Park, Munby, Lincolnshire, LN11 8UT
Luminex is a B&T Associates Ltd company. Revision 2 – November 2022