STREAMLINE COMBI325 325ltr Tank System User Manual

May 15, 2024
Streamline

COMBI325 325ltr Tank System

“`html

Specifications

  • Product Code: COMBI325

  • Country of Origin: United Kingdom

  • Maximum Height: 870mm

  • Maximum Length: 1105mm

  • Maximum Width: 848mm

  • Dry Weight: 91kg

  • Wet Weight: 416kg

  • Min. Inlet Pressure Requirement: N/A

  • Optimum Operating Pressure: 6.9Bar /
    100Psi

  • Standard Water Inlet Connection: Male hose
    lock

  • Waste Water Outlet Connection: Male hose
    lock

  • Pure Water Outlet Connection: Male hose
    lock

  • Electrical Power Supply: 12v Battery

  • Optimum Water Quality: N/A

  • Water Quality Range: N/A

  • Pure Water Flow (optimum output): 5.2 Lpm Per
    Pump

  • Operating Time: Approx. 8hrs per user

Product Usage Instructions

1. Unpacking and Storage

When you receive your CombiTM system, carefully unpack it and
store any additional parts in a safe place for future use.

2. Assembling the System

Follow the provided instructions to assemble your CombiTM system
correctly. Ensure all components are securely connected.

3. Turning the System On

To turn on the CombiTM system, make sure the battery is charged
and press the power button. Wait for the system to initialize.

4. Operating the System

Once the system is on, you can start using it for your intended
purpose. Follow any specific instructions related to water
delivery, reverse osmosis, or other functions.

5. Turning the System Off

To turn off the CombiTM system, safely power it down following
the recommended procedure to avoid any damage.

Frequently Asked Questions (FAQ)

Q: Is the CombiTM system suitable for home use?

A: The CombiTM tank system is designed for industrial
applications and may not be suitable for home use.

Q: What is the recommended operating pressure for the

system?

A: The optimum operating pressure for the COMBI325 model is
6.9Bar / 100Psi.

Q: How often should filters be replaced?

A: Refer to the maintenance section in the manual for guidelines
on replacing filters based on usage and condition.

“`

INSTRUCTION MANUAL
COMBI TM
Codes:
COMBI325 COMBI325RODI COMBI325TR
Available Varitations: – 325Ltr and 500Ltr tank options – Water Delivery, Reverse osmosis
with DI, RODI and MobiTM trolley with DI

English
INSTR-COMBI

These instructions identifies a risk situation which could lead to serious injury. MUST read before operating the COMBI® tank system.

Contents

Responsibilities

General Responsibilities

3

Manufacture Responsibilities

3

Personnel Responsibilities

3

2. Technical Specifcations

Technical Data

3

Technical Data

3

3. Safety Regulations

Electrical Specifications & Safety

6

Safety Precautions

7

Personal Safety

8

System Safety

9

4. Operating the CombiTM System

Unpacking your system

6

Storage of your system

7

About your system

8

Charging your battery

9

How to assemble your system

How to turn your system ON

Operating the CombiTM system

Turning your CombiTM system OFF

5. Malfunctions & Troubleshooting

Controller Troubleshooting

6

Adjusting the calibration on the controller

7

6. Maintenance & Replacing Filters

TDS Meters

6

Prefilters – Usage and Replacing

7

De-ionising (DI) resin filter

Reverse Osmosis Membrane Filters

The Pump

7. Disposal of System and Filters

8. Why Streamline® 9. Warranty Information

2

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

Responsibilities
General Responsibilities These operating instructions allows you to use the CombiTM tank system safely and efficiently. The instructional booklet must be read before setting up, starting or using your streamline® equipment. It is an integral part of the product itself.
Please read the warning and instructions contained in this booklet carefully. They provide important information on the safe use and maintenance of the equipment. Pay particular attention to general safety instructions.
Please keep this booklet in a safe place near your CombiTM tank system for future consultation. Your CombiTM tank system is constructed according to current safety standard and regulations. The latest and current edition is illustrated in this manual. The contents of this booklet should be bought to the attention of all users.
General Responsibilities VARITECH SYSTEMS Ltd, the manufacturer of Streamline®, holds 12-months warranty on all machines and equipment from the date of purchased (see Warranty section 2) VARITECH SYSTEMS Ltd, the manufacturer of Streamline®, is in no case responsible for failures or errors caused by modifications to the unit by customer or other persons.
Personnel Responsibilities The CombiTM tank system is designed and manufactured to be operated in industrial applications. It is important that the operator(s) of the CombiTM tank system have read throughthese operating instructions thoroughly, and understand all safety instructions and regulations.
The CombiTM tank system is not intended for use by children, adolescents, persons under the influence of alcohol / drugs or simply lacking experience and knowledge.
These operating instructions are designed to educate the user, informing t he operator how to carryout the task at hand successfully, whilst avoiding potential dangers that might occur.
Important If needed, training videos can be found on the Streamline® website: www.streamline.systems

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

3

Responsibilities
General Responsibilities
PRODUCT CODE Country of Origin Maximum Height Maximum Length Maximum Width Dry Weight Wet Weight Min. Inlet Pressure Requirement Optimum Operating Pressure Standard Water Inlet Connection (Male hose lock) Waste Water Outlet Connection (Male hose lock) Pure Water Outlet Connection (Male hose lock) Electrical Power Supply Optimum Water Quality Water Quality Range Pure Water Flow (optimum output) Operating Time

COMBI325 United Kingdom
870mm 1105mm 848mm
91kg 416kg N/A 6.9Bar / 100Psi N/A
N/A
N/A 12v Battery
N/A 000ppm ­ 1000ppm
5.2 Lpm Per Pump Approx. 8hrs per user

COMBI325RODI United Kingdom 870mm 1105mm 848mm 113kg 478kg 2.8Bar / 40Psi 6.9Bar / 100Psi 10mm
10mm
10mm 12v Battery 000ppm ­ 600ppm 000ppm ­ 1000ppm 5.2 Lpm Per Pump Approx. 8hrs per user

COMBI325TR United Kingdom
870mm 1105mm 848mm
41kg 366kg N/A 6.9Bar / 100Psi N/A
N/A
N/A 12V Battery 000ppm ­ 600ppm 000ppm ­ 1000ppm 5.2 Lpm Per Pump Approx. 8hrs per user

4

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

Parts & Accessories

COMBI TM
No Filtration
– Twin Operator – 100psi Shurflo Pumps – Digital Flow Controllers – No Filtration – Single Mounted Hose reel
RODI Filtration
– Twin Operator – 100psi Shurflo Pumps – Digital Flow Controllers – Inline TDS Meter – Pre Filtration – Reverse Osmosis Membrane – DI Resin vessel – Waste Water Regulator
TR Trolley
– 100psi Shurflo Pumps – Digital Flow Controller – DI Resin vessel fitted to Trolley

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

5

Responsibilities
Electrical Specifications & Safety
This applies to all CombiTM system configurations Electrical connections must be carried out in respect of current legislation (in compliance with the provisions of the IEC 60364-1 standard) and in accordance with the manufacturer’s instructions. Please check that the installation and sockets are adequate for the maximum power of the appliance indicated on the rating plate. If in doubt, consult a qualified electrician. The correct plug should be fitted by a qualified electrician.

VARITECH SYSTEMS Ltd, the manufacturer of STREAMLINE® declines all liability for damage to persons, animals or things caused by faulty or incorrect connection.

Before connecting the equipment, check that the specification given on the rating

plate corresponds to that of the mains electrical supply.

If the equipment is connected via an extension, use cables with an adequate cross

section, never less than 1,5 mmq. The plug and socket must be watertight.

The electrical safety of the equipment is guaranteed only when correctly and

efficiently earthed as specified in current electrical safety legislation (in

compliance with the provisions of the IEC 60364-1 standard). This fundamental safety

requisite should be verified. If in doubt, ask a professionally qualified electriciant

check the system thoroughly. It is recommended that the electric supply to this

machine should include a residual current device that will interrupt the supply if the

leakage current to earth exceeds 30 mA for 30ms or a device that will prove the

earth circuit.

VARITECH SYSTEMS Ltd, the manufacturer of Streamline® declines all liability for damage to persons, animals or things caused by faulty or incorrect connection.

The equipment can be disconnected from the mains only by unplugging the plug

from the mains socket.

When using any electrical appliance, certain fundamental rules should be respected:

·

Do not touch the appliance with wet hands or feet;

·

Do not touch the appliance with bare feet or unsuitable clothing;

·

Do not pull the power cable or appliance itself to unplug the plug from

the mains. he supply if the leakage current to earth exceeds 30 mA for

30ms or a device that will prove the earth circuit.

6

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM
The innovative CombiTM is a vehicle mounted flat tank system designed to produce pure 000ppm water, through Reverse Osmosis and Deionising filtration, suitable for spot free cleaning. The water tank is baffled to restrict water movement in transit. With the simple removable lithium batteries charging has never been easlier.
Safety Precautions
· It is always recommended to professionally install the CombiTM by the manufacturer or an approved installer. Speak to VARITECH SYSTEMS Ltd for more details.
· If being installed in a vehicle or trailer, always ensure the vehicle/trailer has a suitable payload for the CombiTM to be installed
· Do not use the CombiTM with telescopic poles in the vicinity of power lines, junction boxes, power sockets ­ Please read STREAMLINE® OVA8® operating instructions
· Do not attempt to modify the CombiTM as this could cause a safety hazard or system breakdown
· Never use faulty components or if there is visible damage to the pole or fittings – replace them immediately with original spare parts

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

7

Safety Precautions Stay alert, watch what you are doing and use common sense when operating the CombiTM tank system. Do not use the filtration system while you are tired or under the influence of alcohol, drugs or medication. A moment of inattention while operating the filtration trolley may result in serious personal injury.
Use personal protective equipment to avoid personal injury:

Protective Gloves

Saftey Goggles

Protective Footware

Additional protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection may be required depending on the safety regulations in the operator surroundings.

Additional protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection may be required depending on the safety regulations in the operator surroundings.

8

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

Safety Precautions
The CombiTM tank system is manufactured with the safety of the operator in mind, including some key features such as;
Over Pressure · If the water pressure in the CombiTM filtration system rises
above the maximum 100psi / 6bar pressure, the pressure switch valve shuts on the pump closing the system down, and not letting the pressure in the system rise any further.
· It is important to never open the filter vessels or membrane housings during operation or whilst under pressure.
Over Heating · If the powerful booster pump overheats on the CombiTM
system, an activation switch is triggered and the system will automatically switch off.

Electrical Hazards
· As the CombiTM system is powered by an electrical source, never use expose the equipment in the rain, snow or strong winds.
· Never use the filtration system to clean people and/or animals.
· Before each use, undertake a visual check on all electrical cables for damage. Never use the CombiTM system with a damaged cable.
Mechanical Hazards
· To avoid all mechanical hazards, ensure the CombiTM system is safely secured in position before filling the water tank.

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

9

Operating the COMBITM system
Use only original accessories that come with the CombiTM system, offering maximum quality and security. Failure to use original accessories absolves VARITECH SYSTEMS Ltd, the manufacturer from all liability.
When purchasing the product, make sure it has an identification plate. If this is missing, notify the distributor / manufacturer where you purchased the unit from.
Use of an appliance without an identification plate absolves the manufacturer from all liability. Products without an identification plate should be considered as anonymous and potentially dangerous.
Safety Precautions Your CombiTM system has been carefully manufactured, checked through QC and packaged as a kit.
If your CombiTM is installed in a vehicle or trailer, please move to STORAGE OF CombiTM System.
Packaging (bags, boxes, nails, tape etc.) should be kept out of reach of children as they may represent a potential hazard. Packaging can be recycled according to your local legislation.

10

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM
Storage of your System
Short term storage: 2-4 weeks of no use i. Remove the prefilter housing and pour out the excess water. ii. Remove the DI resin cartridge housing and pour out the excess water. iii. Remove the RO membrane caps for the excess water to drain from the membranes. iv. Ensure you reinstall the top caps on RO pressure vessels. Do not allow them to dry out. v. Ensure you reinstall the prefilters and DI resin cartridge. Do not allow them to dry out.
Long term storage: 4 weeks plus of no use vi. Remove the prefilter housing and pour out the excess water. vii. Remove the DI resin cartridge housing and pour out the excess water. viii. Remove the RO membrane caps for the excess water to drain from the membranes. ix. Remove all filters from the CombiTM system, wrap in individual plastic bags and seal. x. Replace all filter housings and membrane caps without any filters inside. xi. It is important to store the CombiTM system where it cannot freeze. xii. It is important for all filters to not be allowed to dry out when not in use.
Important The unit must be protected from freezing. The following procedures should be followed to protect the unit from bacteria fouling and damage from freezing;

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

11

About your system No Filtration

Hose Reel

Pump Controller 1

Pump Controller 2 Battery Hatch

Outlet 1

Outlet 2

12

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI-RODI

COMBI TM

Hose Reel

DI Filter

Water Inlet Pressure

Outlet 2

Reverse Osmosis
Waste Adjustment Valve
Carbon Filter Sediment Filter Water Inlet

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

13

COMBI-TR

Hose Reel

Streamline Trolley

14

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

15

Stay alert, watch what you are doing and use common sense when operating the CombiTM tank system. Do not use the filtration system while you are tired or under the influence of alcohol, drugsor medication. A moment of inattention while operating the filtration trolley may result in serious personal injury.
To operate the CombiTM system, the operator needs to think of a suitable filling time before commencing on the cleaning task. Filling time takes approx. 2-4hrs (See Filling of CombiTM)
The water enters the CombiTM system through the water inlet connection, and then passes through the three prefilters (Sediment, Carbon, Carbon Block) removing the largest particles in the water before the water enters the membrane.
The reverse osmosis (RO) membrane filters remove up to 98% of the impurities in the water, before it reaches the de-ionising (DI) resin filter where the water is polished and reaches a 000ppm result.

16

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM
About your system
The CombiTM Range includes a Lithium Ion Battery set up. This Battery is to be charged with the charger supplied with the System. It is advised battery is charged after every day of use. Battery can be discharged fully, but is advised to be charged fully prior to every use.
1. Remove the battery from the CombiTM and charge in dry /warm conditions.
2. Plug the Mains plug on the charger into 230v Mains and lights will appear on the charger
3. Plug the Battery connection from charger into the battery
4. Battery Charge will indicate on the charger with green light as charging
5. Full charge will indicate as full green bars
6. Unplug and refit into CombiTM 7. The battery charging cycle is approx.
8 hours to full charge. The run time of the battery is approx. 8 hours continual usage.
Important Only use the Streamline® charger supplied with your CombiTM system. If misplaced, contact your dealer of manufacture immediately. The charger will never over heat. This has a safety function to prevent the battery from over charging. You can operate the system and keep the battery on charge. Pay special attention to the mains electrical supply when operating with water.

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

17

Storage of your System Please see the filling instructions depending on what filtration specification you have on your CombiTM
No Filtration When using the CombiTM with no filtration, you will need to fill via tank lid either by fast filling with a transfer nozzle or connection hose.
Important Your CombiTM does not have any filtration, therefore the operator MUST fill the tank with pure (000ppm) water.
Filtration System When using the CombiTM with filtration, you have the option of filling through the water inlet port, or opening the tank lid and fast filling with a transfer nozzle.
i. Connect the water inlet connection to the mains water via bumper port connection (if supplied) with 10mm pipe.

18

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

ii. Connect the water waste outlet connection to the bumper port connection (if supplied) with 10mm pipe
iii. Ensure that the `waste water regulator valve’ for the Reverse Osmosis filter is fully open (turn anti-clockwise).

COMBI TM

iv. Switch on the mains water, and allow all air to pass through the filter system

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

19

v. Adjust the `waste water regulator valve’, by turning it clockwise, until a 60:40 ratio of pure water to tank and waste water to drain is achieved

Turning your COMBITM system ON i. Connect your pure water hose supplied to the pure water outlet or marked Pure outlet to the hose reel or directly to waterfed pole via mounted Hosereel this is ready for use.
ii. Switch the flow controller on by pressing the button.

20

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

iii. You can adjust the water flow rate by increasing/decreasing the flow rate number until a desired flow rate is achieved. The average flow rate is usually set between 40-50 on the STREAMLINE® controlers (approx. 2.5lpm). The pump MUST run continuously. If the pump is running intermittently whilst water is flowing to the telescopic pole, decrease the speed on the flow controller by pressing button until the pump runs continuously
You are now able to use your CombiTM 325 system. Please ensure you regularly check the water quality with the TDS meter provided.
Important Different cleaning applications may require different water flow rates, i.e. large glass areas with lots of rinsing will need more water than a small window.

Operating your COMBITM system
The CombiTM system is designed for a single or double operator use.
The water supply can sometimes be interrupted for short lengths of time i.e. when the operator moves from window to window. However if the CombiTM system is interrupted for long periods of time, it is best to switch off the pump to save overheating and/or over pressurising, and potentially damaging the system.
If the operator is using 4x jets with the waterfed brush, it is advised to turn up the speed of the controller, to give sufficient water flow for quality cleaning and rinsing. When cleaning windows, remember to pay special attention to the frames, especially if it is the first time this method of window cleaning is being used.
The most important part of the cleaning process is to rinse the glass thoroughly, after the window has been cleaned. To do this, lift the brush away from the glass and move the head from side to side working from top to bottom motion, allowing the water remove all particles from the glass. If you are cleaning windows on a warm day, the rinsing procedure must be done meticulously, as warm, direct sunlight can cause spotting due to insufficient rinsing.

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

21

Turning your COMBITM system OFF The COMBITM system is designed for a single or double operator use. i. Press and hold the button on
the STREAMLINE® flow controller, switching off the Shurflo pump
ii. Remove all hoses and safely store and wind hoses in.

22

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

Malfunctions and Troubleshooting
Please see the filling instructions depending on what filtration specification you have on your CombiTM i. Low water pressure or water supply at waterfed brush
a. Check for any blockages or kinks in hose b. Disconnect all extension hose/hose reels and connect the COMBITM filtration
system directly to the telescopic pole c. Clean or replace the sediment filter d. Contact service centre ii. High waste water flow and low pure water flow a. Check if membrane has the plug installed ­ if so, replace membrane b. Contact service centre iii. High pure water TDS a. Check membrane quality ­ replace membrane b. Check DI filter ­ replace resin beads in DI cartridge c. Contact service centre iv. Controller stating DE’ orPS’ constantly a. Check for any blockages in hose or telescopic pole tubing b. Check for any blockages in membrane c. Raise the calibration on the controller d. Contact service centre v. Controller flashing `BAT’ constantly a. Plug in battery charger immediately before the battery is flat b. Contact service centre

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

23

Controller Troubleshooting No Filtration · dE ­ A dead end has been detected.
The pump has been turned off automatically by the controller, as there is a water stop some where in the system.
· PS ­ The pressure switch has been activated. This means the pressure has exceeded the pressure switch rating. Check if there is no water blockage or reduce the pump speed to lower the resistance.
· Bat (Pump still working) ­ Your battery voltage has dropped below 11.5V. Re- charge your battery as soon as possible, before your pump finally stops.
· Bat (Flashing and pump stopped) ­ Your battery voltage has dropped below 11.0V. The pump has been stopped by the controller to prevent possible damage to the battery. Re-charge your battery as soon as possible. If you have a split charge relay fitted to your
ECOSTREAM® system, start your vehicle engine which will then start the charging process.
Adjusting the calibration on the controller
The Streamline® controller can automatically shut down the pump automatically
This is known as dead-end’ and labelleddE’ on the controller.
The sensitivity can be adjusted and set by the operator, if the controller is turning off too early or too late.
i. Switch the flow controller on by pressing the button

24

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

iii. To adjust dead-end detection, press and hold and at the same time. Wait for Cal’ to display and flash on the screen. hold vi. WhenCal’ displays on the screen, adjust dead-end detection up with (less sensitive, turns off at higher pressures) or down with (more sensitive, turns off at a lower pressure).
Or
vii. Press button to set and save the final calibration

COMBI TM

Warning: Do not set the calibration too high
Setting calibration higher than necessary places extra strain on both the pump and the controller in a dead-end situation. This can result in damage to both the pump and your controller.

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

25

6 Maintenance & Replacing Filters
Maintenance & Replacing Filters
Care and maintenance of your EcostreamTM system will ensure it is well looked after and running smoothly every time. It is recommended to run a weekly, monthly and quarterly examination on the EcostreamTM system to ensure all filters are adequate and effective for producing pure 000ppm water quality.
Weekly inspection · Keep a check on the pure water TDS by using the handheld TDS meter. This measures
in parts per million (ppm). If the output reads higher than 3ppm, it is recommended to change the de-ionising (DI) filter, and make a note in the back of the inspection booklet · Keep a check on the battery voltage by running through the controller function until you reach `BAT’. A good healthy battery will read between 11V and 12.4V.
Monthly inspection · Each month it is recommended to flush through the reverse osmosis (RO) membranes and reset
the ratio between pure water output and waste water output. The waste water valve should be opened 100% to allow waste water to flow out for approx. 5mins. Gradually reset to 60% pure and 40% waste water. Quarterly inspections
· Depending on the usage, however, it is advised to change the prefilters at least once a quarter. · Complete a check on all membranes to ensure performance is still acceptable
Warning Ensure the CombiTM system is not operating or under pressure when maintenance or filter replacements are being undertaken.

26

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM
TDS Meters This system relies on a series of filters to produce pure 000ppm water. To ensure that your COMBITM filters operate efficiently, the filters will need to be changed in accord with your water harness. Open the cabinet by turning the two latches on either side of the front cover, using the key supplied. Lower the front cover carefully ensuring that the external controls are not damaged.
The COMBITM is fitted with two inline TDS meters.
1. The TDS meter, which measures the the IN Reverse Osmosis filtered water (out). If the Reverse Osmosis (out) reading is above 40ppm, a replacement RO membrane is needed.
2. The TDS meter, which measures the the IN Reverse Osmosis filtered water (out). If the Reverse Osmosis (out) reading is above 40ppm, a replacement RO membrane is needed.

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

27

Maintenance & Replacing Filters
The prefilter set are the first initial filter set the feed water will pass through.
Usage
Either quarterly replacement or approx. 25,000ltrs of mains water running through, whichever comes quickest
How do I change the prefilter set?
The prefilter cartridges are quick release, and can be replaced by simply unscrewing the CLK cartridge (twist to the left) and replacing them with new CLK cartridges. It is important to keep the prefilters are kept in the correct order for quality filtration. – Sediment prefilter – Carbon Block prefilter Ensure you safely and securing tighten up the housing to ensure the system is safe under operating pressure
PRODUCT CODE: KIT02310-CLK

28

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

De-ionising (DI) Resin Beads ­ usage and replacing
The DI filter is a vessel containing DI resin beads. The DI resin cannot be regenerated and needs replacing should the `out’ TDS reading rise above 006ppm.

To replace the DI resin filter:
1. Ensure the COMBI is switched off and no water filling into the tank
2. Remove the inlet and outlet hose from the DI filter
3. Remove DI filter from COMBI by removing the support bracket
4. Unscrew the DI filter head and remove both the head and riser carefully
5. Empty of the used resin beads into general waste bin, this is not harmful, but care needs to be taken to prevent resin spillage
6. Refill the DI filter with new resin beads, ensuring that the filter is filled no more than three quarters
7. Reassemble the head and riser, it this is tight, fill the DI filter up with small amount of water to lubricate the riser to sink into the resin Re clamp the filter back into position before attaching the inlet and outlet hose connections. Pay special attention to INLET/OUTLET pipes and water flow. OUTLET is fitted to tank and INLET is fitted to Filter Board.

PRODUCT CODE: MB115

Ensure you safely and securing tighten up the housing to ensure the system is safe under operating pressure.

Warning
Disposing of resin beads can create a slippery surface. Care needed to dispose of resin beads effectively. Remove all over spill immediately

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

29

Reverse Osmosis (RO) Membrane Filters ­ usage and replacing
The RO membranes are the core part of the water filtration ­ produce up to 98% of water filtration.

Usage
Either yearly replacement or approx. 250,000ltrs of pure water running through, whichever comes quickest

How do I change the RO membranes?
The RO membrane filter is hidden below thecentre cover in the water tank..
Please pay special attention to the flow direction on the membrane housings and on the membranes themselves.
1. Ensure the COMBI is switched off and no water filling into the tank
2. Remove the inlet, outlet and waste water hose connections from the stainless steel membrane housing
3. Release the stainless steel membrane housing from the clamps and remove the used RO membrane filter into general waste
4. Reinsert the new RO membrane filter in the housing, ensuring the membrane seal is located on the inlet of the stainless steel membrane housing
5. Reassemble the stainless steel membrane housing, and clamp back into position be fore attaching the inlet, outlet and waste water hose connections

30

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM
The Pump
The pump fitted to the COMBITM systems are protected by an in-line strainer filter, with a clear top allowing for visual inspection. If any debris accumulates in the strainers, unscrew the top and flush out with clean water. The pump has a built in pressure switch. When switched on it will pump until it has reached the maximum pressure setting before cutting out. This is a safety feature. However, the pressure switch may burn out if the pump is allowed to run intermittently. To avoid this happening, make sure that the pump speed is correctly set on the flow controller. The pump must not be stored under pressure as this will invalidate the warranty.
6 Maintenance & Replacing Filters
The COMBITM system is classified as special waste. It must be taken apart and divided into uniform sections which should be disposed of according to current legislation. Do not use the components removed as spare parts. All filters are disposable as unharmful general waste.

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

31

Why Streamline?
Flexibility
· Streamline® systems can be built according to customers’ exact requirements
· For non-standard systems, the user’s needs or specifications are listened to and turned into reality.
Quality
· Whilst price is important, quality is remembered long after price is forgotten
· We insist on sourcing brand name products from around the world, only of a reputable quality, and bring them together under the Streamline® name
· All Streamline® products carry a full one year’s warranty, according to the manufacturers’ standard terms and conditions of sale.
Service
· We have an in-house technical helpline able to answer most of your questions relating to the capabilities and functionalities of all Streamline® products
· If we get it wrong, we will put it right. If you are sent a wrong item, we will immediately attend to sending you the correct item and arrange a collection of the wrong item without any quibbles
· Streamline® is backed by a comprehensive range with massive stocks providing you with a `one stop shop’ for all your requirements.

Manufatured in the United Kingdom

Checked & tested by quality control

32

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

10

Warranty Information

Warranty Information
STREAMLINE® Warranty

The warranty on all Machines and Equipment is for 1 year (12-months) from RECORDED DATE OF PURCHASE.
THIS WARRANTY EXCLUDES NORMAL MAINTENANCE ITEMS, including but not limited to HOSES, FILTERS, O-RINGS, DIAPHRAGMS, VALVES, GASKETS, CARBON BRUSHES and damage to motors and other components as a result of failure to replace normal maintenance items. THIS LIST IS NOT EXHAUSTIVE.
If Streamline® receives notice of such defects during the warranty period, Streamline® will either, at its opinion, repair or replace components which prove to be defective.
Replacement parts will only be supplied under warranty, upon the inspection and approval of the defective parts by Streamline®
Should it be necessary to supply replacement parts before the opportunity to inspect, these will be charged at current prices and credit will only be issued upon subsequent inspection and warranty approval by Streamline®

Wear and tear, misuse, abuse improper maintenance, frost damage, the use of chemicals other than those supplied or approved by Streamline®, improper installation or repair, unauthorised modification, incidental or consequential costs, loss or damage, service, labour or third party charges, the cost of returning defective parts to Streamline®.
This warranty constitutes the exclusive remedy of any purchaser of a Streamline® unit and is in lieu of all other warranties, express or implied, including without limitation any implied warranty of merchantability or fitness for use, to the fullest extent permitted by law. In no event shall any implied warranty of merchantability or fitness for use exceed the term of the applicable warranty stated above and Streamline® shall have no other obligation or liability.
Important
Unfortunately these rights cannot be transferred to a third party.

The customer is responsible for the cost of return of the defective part. If warranty is approved, Streamline® will pay for the cost of the repaired or replacement part.
This warranty excludes the following conditions and circumstances which are at the discretion of Streamline®

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

33

Notes

34

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

COMBI TM

W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830

35

Hamilton House, 8 Fairfax Road, Heathfield Industrial Estate, Newton Abbot Devon, TQ12 6UD United Kingdom
Telephone: +44 (0) 1626 830 830 Email: sales@streamline.systems Visit www.streamline.systems

INSTR-COMBI

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Streamline User Manuals

Related Manuals