BONDLINE SRM3 Surface Resistance Test Kit Instruction Manual

May 15, 2024
BONDLINE

BONDLINE SRM3 Surface Resistance Test Kit

BONDLINE-SRM3-Surface-Resistance-Test-Kit-PRODUCT

Introduction

  • Thank you for purchasing a Surface Resistance Test Kit. Please read this instruction manual in great detail before operating the device. Keep this manual readily accessible for later reference.

Description

  • This professional analog auditors kit can be used for measuring surface resistivity, point-to-point resistance, point-to-ground resistance, and bonding points to the ground.
  • The SRM3 kit has been designed specifically for testing surfaces used in the EPA. Testing and auditing all elements within the EPA is essential to comply with industry standards.
  • Incorporating the latest requirements of the IEC 613340-5 technical report. Calibration testing is recommended regularly (annually). This product is CE-approved and RoHS and REACH compliant.

SRM3 Packing List

Make sure each of the following items is included in the kit.

  1. Unique analogue meter …………………………………………………………………………………………………………………..
  2. 2 x 2.5kg weights …………………………………………………………………………………………………………………………… .
  3. Connecting leads …………………………………………………………………………………………………………………………… .
  4. 9V battery ……………………………………………………………………………………………………………………………………… .
  5. Conductive foam discs …………………………………………………………………………………………………………………….
  6. Carry case ……………………………………………………………………………………………………………………………………… .
  7. Square probes ………………………………………………………………………………………………………………………………. .
  8. Instruction manual ………………………………………………………………………………………………………………………….
  9. Calibration certificate ……………………………………………………………………………………………………………….BONDLINE-SRM3-Surface-Resistance-Test-Kit-FIG-1

Measurement Modes

  • Both 1 0v and 1 00v test voltages are incorporated in the tester with a choice of automatic ranging from 1 0v – 1 00v, cleverly detected as you move from.
  • Conductive to Dissipative and insulating surfaces, or permanent switching to 1 0v only, an option preferred in very sensitive areas.

Colored segments and LEDs indicate the following:

  • GREEN – Conductive >1 0A(3) -<1 0A(6)
  • YELLOW – Dissipative >1 0A(6) -<1 0A(11)
  • RED – insulative >1 0A(12)

Operation

  1. Check that a good quality Alkaline PP3 battery is fitted – the battery compartment is located at the rear of the enclosure. If at any time the battery voltage drops below 6.5 volts, the yellow battery low indicator will light.
  2. The aluminum carry case comes with a carrying strap, and locking keys and is lined with conductive foam.
  3. Connect the RED test lead into the left side RED banana socket, and the BLACK test lead into the right side BLACK banana socket. To check the meter is functional, press the GREEN test button. The moving coil needle will move from left to right showing lnsulative above 10/13.
  4. Connect the two 2.5 kilos (51 b) weights to the other end of both the RED and BLACK test leads. Place the weights gently onto the surface that requires testing and press the test button.
    • The Resistance of the surface under test will be displayed in Ohms.
    • The GREEN segment of the meter indicates conductive from> 1.0 x 10/3 to< 1.0 x 10/6. Conductive measurement is taken at a test voltage of 10 volts.
    • The YELLOW segment indicates dissipative > 1.0 x 10/6 to< 1.0 x 10/12.
    • These measurements are taken automatically at a test voltage of 100 volts unless the test voltage range switch is manually switched to 10 volts.
    • 10 volts should only be used for measuring dissipative resistances, if there is a high risk of damaging components on or around the area under test.
    • At any other time, the meter should be set to 10/100 volts.
    • The RED segment indicates insulative> 1.0 x 10/12.
    • For a simple visible check through its range, the meter will indicate Conductive, Dissipative, and insulative via three LEDs, GREEN = Conductive YELLOW Dissipative RED insulative.
  5. The model SRM-3 and the kit include an SP-01 square probe for checking surface resistance in Ohms per square as used in standard ASTM-D-257, as well as point-to-point resistance.
    • When using the SP-01 square probe, connect the RED and BLACK test leads to their corresponding RED and BLACK sockets.
    • Place one 2.5 Kilo (51 b) weight on the surface of the square probe and press the test button, the measurement now taken is in Ohms per square.
    • The SRM3 conforms to the current, IEC61340-5-2:2018, IEC61340-2-3, I EC61340-4-1, ANSI 20.20 standards.

Calibration

  • All resistances are built using matched fixed resistors. They are measured using an ohm meter which is of known accuracy and the standards used are traceable to UKAS.
  • No variable resistors e.g. potentiometers are used. The resistances should nevertheless be re-checked once a year. Calibration is carried out with a Resistance Decade Box.
  • The resistance decade box required will need a range of either from > 1 kilohm to 999 megohms or 1 QA(9). Measurements greater than 1 QA(9) are calculated using cad generated techniques, as high resistances greater than 1 QA(9).
  • Connect the test leads from the resistance decade box to the RED and BLACK banana sockets of the checker. Set the decade box to the desired resistance i.e. 1 QA(3) = 1 K, then press and hold the checker’s test button.
  • The 1 QA(3) LED should light and the analog meter should read 1 QA(3), 10 K = 1 QA(4), the analog meter should read this, and so on.
  • To measure the changeover point between decades, increase the resistance of the decade box while pressing the checker’s test button. Record the resistance when the next analog meter moves up a decade permanently (this is the changeover resistance).
  • Please note that the checker has no internal parts to adjust, so verification of calibration can be achieved by using the above process. If verification cannot be achieved the unit should be returned to the supplier.
  • sales@bondline.co.uk
  • www.bondIine.co.uk
  • +44 (0)1793 511000
  • The information contained within this instruction manual is for guidance only.
  • We make no warranties expressed or implied and assume no liability regarding any use of this information. (Review February 28th 2024)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals