Introduction

Thank you for purchasing a Surface Resistance Meter. Please read this instruction manual in great detail before operating the device. Keep this manual readily accessible for later reference.

Description
An easy-to-use, portable instrument for measuring both surface resistivity and resistance to ground (using 10 / 100 volts). Manufactured with soft probes for maximum and consistent surface contact to give more accurate readings. The battery is very easy to change. This product is CE-approved.

Packing List

Make sure each of the following items is included in the pack.

  1. Meter……1
  2. Required test leads….1
  3. 9V battery……..1
  4. Carrying pouch……1
  5. Instruction manual…1
  6. Calibration certificate (valid for 1 year)…..1

Specifications

BONDLINE-SRM1-Surface-Resistance-Meter-FIG-2

Testing Guidance

  • Testing and auditing all elements within the EPA is essential to comply with industry standards. All test instruments are manufactured to the very highest quality allowing qualification to council directives 89/336/EEC.
  • The SRM1 has been designed specifically for testing surfaces used in an EPA. It measures in Ohms per Square and meets the requirements of IEC 613340-5-1/2 and EN100 015/1
  • European standard. Automatic auto-ranging 10v and 100v test voltages are incorporated into the tester, switching as you move from conductive, dissipative and insulative surfaces. The SRM100 is also capable of testing resistance to ground.

Setup and Operation

  1. Fit the supplied 9V battery; the battery compartment is located at the rear of the enclosure. The unit is now ready to use.
  2. To test surface resistance, place the unit on the surface to be tested and press the test button.
  3. To measure resistance to ground, insert one end of the supplied test lead into the 3.5mm socket located on the front panel of the meter and attach the other end to your ground point. Press the test button.
  4. GREEN LEDs indicate a conductive reading. Measurements are taken at a test voltage of 10V.
    YELLOW / ORANGE LEDS indicate a dissipative reading. Measurements are taken automatically at a test voltage of 100 volts.
    RED LEDs indicate an insulative reading. Measurements are taken automatically at a test voltage of 100 volts.

BONDLINE-SRM1-Surface-Resistance-Meter-FIG-1

The information contained within this instruction manual is for guidance only. We make no warranties expressed or implied and assume no liability regarding any use of this information. (Re-view February 28th 2024)

  • Registered at Cardiff No. 2933918
  • Registered Office: Bondline Electronics, Unit 4,

Rivermead Industrial Estate, Rivermead Drive, Swindon, Wiltshire, SN5 7EX

MORE INFORMATION

sales@bondline.co.uk
www.bondline.co.uk
+44 (0) 1793 511000

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals