BONDLINE KS2453 Self Cleaning Suspended 3 Fan Ioniser User Manual

May 15, 2024
BONDLINE

BONDLINE KS2453 Self Cleaning Suspended 3 Fan Ioniser

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
PRODCUT

Introduction

Thank you for purchasing a Self-Cleaning Suspended 3-Fan Ioniser. Please read this instruction manual in great detail before operating the device. Keep this manual readily accessible for later reference.

Description

The KS2453 self-cleaning suspended 3-fan ionizer adopts the DC working method and features a multi-unit independent ion transmitter combination, and fan step-less speed regulation. The 3-fan ionizer is suitable for static removal in a large area, measuring 800 x 55 x 150mm (LxWxH) in size. It features a standard tungsten alloy needle which offers a longer lifetime compared to titanium and silicon materials. The ionizer effectively solves the problems caused by static electricity: static removal, prevent adhesion of objects, prevent material splash, prevent static electricity, and prevent blockage of the feeder. Supplied with UK plug as standard, EU plugs available on request.

Properties

Input Voltage| AC220V/50 Hz or 110V/60Hz
Power| 18W
Working Voltage| ±DC4000-DC7000V
Ion Emission| Steady-state DC
Emitter Electrode| Tungsten All oy
Discharge Structure| Uncoup led electr ica l contact (discharge cylinder)
Discharge Range| 800 x 300 x 750mm (LxWx H)
Discharge Speed| :53s (450mm vert ica l from the center of the air outlet)
Ion Balance| :5 I ±10V I (450mm vert ica l from the center of the air outlet)
Alarm Indicator| The power indicator ligh t on indicates working normally
Air Volume| :5 3* 89.1CFM
Aud io Noise| :560db (150mm away from the air out let)
Ozone Thickness| :50.05ppm (150m m from the air outlet)
Operating Temperature| 0-50°C
Operating Humidity| 30-70%RH
Dimensions| 800 x 55 x 150mm (LxWx H) (Fan body size)
Packaging Accessorie s| 1 pair of L-shaped alum inium spray powder mounting bracket, 1 pair of bakelite scre w han d les (M6x12)
Shell Material| Alum inum powde r spray
Net Weight| 2500g (Including power cord, bracket accessories , etc.)
Gross Weight| 4200g
Warranty| 1 Year
Certification| CE

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-1

The test data as follows (test distance: 450mm in front, maximum air volume): BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-2

Working Way
The KS2453 ioniser uses positive and negative synchronous emission electrodes to generate corona discharge through DC high voltage, ionize air molecules and generate a large number of positive and negative air ions, which are blown to the surface of the object with electrostatic to be eliminated by the fan.

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-3

Product Details

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-4

Product Dimensions

Note : The outside drawing may change slightly due to improvement. They should comply with the real device.

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-5

Installation

  • Use screws or bolts to fix on a firm and flat surface (such as a wall or shelf).
  • The angle of the ionizing air blower can be adjusted by the knobs on both sides of the bracket to achieve the best static elimination effect.

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-6

Installation Tips

  1. Place the ionizing air blower in the working area where static electricity is to be eliminated. The installation angle should be perpendicular to the surface of the charged body and about 300 to  750mm away from the static electricity object.
  2. The ionizing air blower should be at least 300mm away from the metal conductor and grounding body.
  3. Two ionizing air blowers should be installed side by side with an interval of more than 200mm away from obstacles.
  4. The air inlet is at least 150mm away from the wall.

Packing Accessories

BONDLINE-KS2453-Self-Cleaning-Suspended-3-Fan-Ioniser-
FIG-7

Safety Warning &

  1. Read the operating instructions carefully before installing and using the device.
  2. The whole equipment must be reliably grounded during use.
  3. Do not use the device when the humidity is higher than 70%.
  4. Do not use the device in an inflammable and explosive environment.
  5. It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by professional personnel.
  6. The product is strictly prohibited from touching liquid during use, otherwise, there will be abnormal, resulting in electric shock or fire.
  7. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.
  8. The product is specially designed for removing static electricity and is strictly prohibited for other purposes. Any abnormal use may cause machine failure, electric shock, fire, and other hidden dangers.
  9. It is strictly forbidden to touch the electrode needles when power is on, otherwise, it is easy to cause a fault and electric shock accidents.
  10. A discharge needle is a sharp metal object, please use it with care.
  11. Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the specifications may cause damage or even failure to the product.
  12. Check the power cord and communication line regularly. If it is damaged, replace it immediately; otherwise, leakage, poor communication, and abnormal operation may occur.

Trouble Shooting


No .

| ****

Problems

| ****

Reasons

| ****

Solutions

---|---|---|---






1

| ****



The indicator on the fan panel is off

| ****

Poor contact of the power cable





Power supply voltage mismatch

| ****

Check whether the power cable is in good condition and securely connected




Confirm the power supply specification INPUT:220VAC SOHz

 | ****

The electrostatic

| ****

Discharge needle is polluted and damaged

| ****


Clean or replace the discharge needle

2| removal performance is obviously reduced| ****


Bearing set of ionising air blower is improper

| ****



Confirm the best bearing set




3

| ****

The  electrostatic removal performance is reduced

| ****


There are conductors or other ionising air blowers around

| ****


Remove (moving) conductors or other ionising air blowers





4

| ****



Unable to discharge

| ****

High voltage module is damaged



Main-board chip is damaged

| ****


Return to factory for maintenance



Return to factory for maintenance



5

| ****

The product is smoky or burnt

| ****

The main control board components are burnt out

| ****


Return to factory for maintenance

Maintenance

  1. The ionizing air blower should be cleaned and maintained in time according to the use environment and the required electrostatic protection requirements to ensure the good performance of the product. That is, gently remove the carbon deposits on the discharge electrode and metal net cover with an electrostatic brush, dust-free cotton swab, and dust-free cloth dipped in anhydrous alcohol.
    Note:

    • A. Operation must be done 10 minutes after the power cut-off.
    • B. It must be cleaned when dust or white stuff appears on the tip of the needle during use.
    • C. The ionizing air blower must be powered on after the alcohol is completely volatilized after cleaning. No other organic solvent can be used to clean the ionizing air blower.
    • D. The alloy electrode is a consumable product that is not included in the scope of the warranty and will be charged for replacement when repairing.
  2. Do not press or rotate the control buttons on the fan panel too hard; otherwise, the device will be permanently damaged.

  3. If the working indicator light on the front panel of the fan is off or red, it should be stopped and repaired by professional maintenance personnel. It can be used only after the electrical performance index is normal.

After-Sales Service

  1. KS2453 self-cleaning suspended 3-fan ionizer has undergone rigorous testing and aging treatment before ex-work. Its performance has completely reached the relevant indicators marked in the usage instructions.
  2. Bondline makes a commitment to the customer that any defective parts inspected by Bondline will be repaired or replaced free of charge within one year from the date of purchase. However, this commitment does not apply to: The device is incorrectly used or installed; Damage caused by negligence or accident during use; Modified, disassembled or repaired by other service departments not authorized by Bondline Electronics Ltd.
  3. Bond Line shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

[email protected]
www.bondline.co.uk
+44 (0)1793 511000
The information contained within this instruction manual is for guidance only. We make no warranties expressed or implied and assume no liability regarding any use of this information. (Re-view February 29th 2024)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BONDLINE User Manuals

Related Manuals