Danfoss KE04106 Valve Drive Amplifier User Guide
- May 15, 2024
- Danfoss
Table of Contents
Danfoss KE04106 Valve Drive Amplifier
Product Information
Specifications
- Model: KE04106 Valve Drive Amplifier
- Issue: 2
- Date: September 1996
- Supply Voltage: 12 Vdc (11 to 15 Volts)
- Input Impedance: 240 ohms
- Start Current : 4 mA nominal (1 Volt)
- Full Stroke Current: 20 mA (4.8 Volts)
- Maximum Output Current : 100 mA into a 25-ohm load
- Direct Output: 200 mA at 10 volts maximum
Product Usage Instructions
Dimensions
Dimensions of the KE04106 in Millimeters (Inches):
- Length : 114.30 mm (4.50 in)
- Width: 101.60 mm (4.00 in)
- Height: 76.20 mm (3.00 in)
Installation Steps
- Ensure the supply voltage is within the range of 11 to 15 Volts.
- Connect the input transducer/controller to the unit using a 4 to 20 mA signal.
- Connect the output to the desired load, ensuring it does not exceed 25 ohms.
- Verify all connections are secure before applying power.
(FAQ)
- Q: What is the maximum output current of the KE04106 Valve Drive Amplifier?
- A: The maximum output current is 100 mA into a 25 ohm load.
- Q: What is the input impedance of the unit?
- A: The input impedance is 240 ohms.
Specification
KE04106 Valve Drive Amplifier
- ISSUE: 2
- DATE: September 1996
GENERAL DESCRIPTION
The device is a free–standing amplifier mounted on 4 standoffs. Current or voltage signal from a transducer/controller, through the amplifier, produces current to drive electrohydraulic actuators. Connections to the amplifier are via screw terminals
DIMENSIONS
Dimensions of the KE04106 in Millimeters (Inches).
CONNECTION DIAGRAM
OUTPUT CHARACTERISTICS
- SUPPLY VOLTAGE
- 12 Vdc (11 to 15 Volts)
- INPUT IMPEDANCE
- 240 ohm
- START CURRENT
- 4 mA nominal (1 Volt)
- FULL STROKE CURRENT
- 20 mA (4.8 Volts)
- MAXIMUM OUTPUT CURRENT
- 100 mA into a 25-ohm load
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>