HANECO Dular Fix TRI Fixed and Adjustable LED Downlight Installation Guide
- May 15, 2024
- HANECO
Table of Contents
HANECO Dular Fix TRI Fixed and Adjustable LED Downlight Installation Guide
This range of Haneco Lighting LED products have been tested as AS/NZS60598.2.2:2001 standards and are approved to the luminaire will not exceed 90°C when side abut or covered with ceiling insulation. Building insulation is used to abut and cover the luminaire must meet the following requirement:
- Be of a type that can maintain it’s dimensions and structural integrity when exposed to the maximum surface temperatures of the class of luminaire, being 90°C and must withstand a 30s needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.
- (New Zealand only) Loose fill insulation as defined in NZS4246 is not permitted to abut or cover this luminaire.
INFO & WARNING
The minimum clearance distance from the top of the luminaire to any building
insulation (mm)…….| Omm
The minimum clearance distance from the side of the luminaire to any normally
building insulation (mm)……..| Omm
*INSTALLATION
-
Cut 90mm diameter hole
-
Connect live and neutral into the luminaire
-
Select CCT setting (WW, NW, CW)
-
Hold mounting clips up to sides of downlight and insert downlight into cut-out so that the springs retract onto rear face of ceiling
DULAR-FIX-TRI DULAR-FIX-BLK Diagram Note: Ceiling max. thickness
≤14mm
Diagram Installation of the product is to be completed by a licensed
electrician, in accordance with these instructions and relevant New Zealand
standards and local regulations.
Warning:
a. Type Y: If the external flexible cable or cord of this luminaire is
damaged, it shall be exclusively replaced by the manufacturer or by a service
agent or licenced electrician in order to avoid hazard.
b. Non-user replicable light source.
c. The diffuser is not replaceable.
For more information
www.haneco.com.au
1300 001 LED