Diaphragm Pump Manual — 31 &35 Series
New from us, the 31 Series & 35 Series pumps are capable of continuous heavy duty and extreme workloads. Matched with high performance motor, the 31 Series has extreme chemical capability and goes beyond the normal call of duty with many other additives as well. This 3 chamber diaphragm pump provides up to 1.8 GPM and Is capable of self-priming up to 6 vertical feet. and an ion dry without damage. They are easy to Install. service and winterize.
FEATURES
- 3 chamber diaphragm pump
- Continuous duty
- Self priming
- Run dry capable for normal workloads
- Automatic: controlled by pressure switch
- Industry standard mounting pattern
- Quiet Operation
- Ignition protected
APPLICATIONS
- Sprayer fixtures (veleCle.mounted sprayers, electric sprayers)
- Cleaning machines. humidifier, w ter purification, medical apparatus
- Food beverage filling & liquid transfer
- Solar water system
- Any other pressurization system
INSTALLATION
Materials
- diaphragm pump with related accessories
- (at least) pieces of flexible. reinforced hose piping, with collapse”, strength of twice the inlet collapsiop pressure( hose must be minimum at ID for 31 serves and St for 35 series) 4 stainless steel hose damps and screws 4 screws to fasten the pump to the mounting surface 1 °Web-kW cutoff switch 1 fuse 1 screwdriver 1 strong cutting implement for tubing (rf desired) Teflon tape or sealant
Setup
- The pump may be mounted in any position. If mounted vertically, the pump head should be in the down position to avoid leakage into the motor casing in the event of a malfunction.
- Secure the feet, but do not compress them. Overtightening the seaming screws may reduce their ability to dissipate noise and vibration.
- Intake hose must be minimum 318′ (10 mm) 113 reinforced hose for 31 series and 5/8″ (15 mm) ID reinforced hose for 35 series. Main distribution line from pump outlet should also be 3/8″ (10 mm) for 31 Series and 5/13a (15 Mal) for 35 series ID with branch and individual supply lines to outlets no smaaer than 3/8″ (10 mm).
- Plumb the system using high pressure (2x pump rating), braided, flexible tubing to minimize vibration/noise.
- Do not apply inlet pressure in excess of 30 psi. In general, try to avoid any inlet pressure completely.
- Avoid any kinks or fittings which could cause excessive restrictions.
- Strainer should be attached to the inlet side.
- The fittings must be secured to avoid leakage.
- Use clamps at both ends of hose to prevent air leaks into the water line.
- If a check valve is installed in the plumbing, it must have a cracking pressure of no more than 2 psi.
- If applying a sealer or plumbing tape, be careful to not overtighten, as they may be sucked into pump.
- This pump should be wired on its own dedicated circuit. Connect the positive lead (red) to the positive terminal of your battery and the negative wire (black) to the negative terminal of your battery.
- In an easily accessible location, install a switch to control electricity to the pump. Turn the pump off when not used for extended periods or when the tank is empty.
- The electrical circuit should be protected with an over-current protection device (fuse) in the positive lead. This pump requires a 20 amp fuse.
- The pump circuit should not include any other electrical loads.
- As the water supply pump is non-essential, reference the wire chart under the electrical information. Be sure to have the correct wire sizing for the length of wire you are using.
- After installation, check the voltage at the pump motor. Voltage should be checked when pump is operating. Full voltage must be available at the pump motor at all times.
Notes
- Flexible potable water hose or PEX tubing is recommended instead of rigid piping at pump. If you choose to use rigid piping, provide a short length of hose between pipe and the pump to avoid noise and vibration.
- We do not recommend the use of metal fittings. When possible, use the provided plastic fittings.
- Do not adjust the bypass personally without the help of technician.
- Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump. Please do maintenance and winterize the pump at appropriate times, especially before and after a period of storage.
- All 115 VAC and 230 VAC pump motors and systems, MUST be ground per local and state electrical codes.
115 AC| BLACK (common). WHITE (neutral). GREEN (ground)| a16 AWG C-UL-TEW / UL 1015 (or heavier)IMmr)
---|---|---
230 AC| BROWN (common), BLUE (neutral), GRWYELL (ground)
ELECTRICAL INFORMATION
Ft. (M) | AWG (MM2) | |
---|---|---|
0-20 (0-6) | 16 AWG | |
20-30 | (6-9) | 14 AWG |
30-50 | (9-15) | 12 AWG |
50-65 | (15-19) | 10 AWG |
REPAIR KITS
Key | DOSCIIPU | Quantity |
---|---|---|
A | Pump Head Assembly | 1 |
B | Valve Assembly | 1 |
C | Diaphragm Assembly | 1 |
D | Motor Assembly | 1 |
1 | Pressure swItch | 1 |
2 | Diaphragm of Pressure Switch | 1 |
3 | Pump Head | 1 |
0 | Diaphragm | 1 |
5 | Rubber Feet | 4 |
6 | Iron Base Plate | 1 |
7 | Motor | 1 |
Key | Desenpeon | Quantity |
---|---|---|
A | Pump Head Assembly | 1 |
B | Vane Assembly | 1 |
C | Diaphragm Assembly | 1 |
D | Motor Assembly | 1 |
1 | Pressure switch | 1 |
2 | Diaphragm of Pressure Switch | 1 |
3 | Oriole Attach Clip | 2 |
4 | Pump Head | 1 |
5 | Diaphragm | |
6 | Rubber Feet | 4 |
7 | Iron Base Plate | 1 |
8 | Motor | 1 |
TROUBLESHOOTING
PULSATING FLOW— PUMP CYCLES ON AND OFF
- Check lines for kinks.
- Plumbing lines or fittings may be too small.
- Clean faucets and filters.
- Check fitting tightness for air leaks.
FAILURE TO PRIME BUT MOTOR OPERATES – NO PUMP DISCHARGE
- Restricted intake or discharge line.
- Air leak in intake line.
- Punctured pump diaphragm.
- Initial amp supply is not enough to sufficiently start the motor.
- Debris clogged in the valves.
- Crack in pump housing.
MOTOR FAILS TO TURN ON
- Loose or improper wiring.
- Pump circuit has no power.
- Blown fuse.
- Failed pressure switch.
- Defective motor.
PUMP FAILS TO TURN OFF AFTER ALL FIXTURES ARE CLOSED
- Punctured diaphragm.
- Discharge line leak.
- Defective pressure switch.
- Insufficient voltage.
- Clogged valves in pump head.
LOW FLOW AND PRESSURE
- Air leak at pump Intake.
- Accumulation of debris inside pump or plumbing.
- Worn pump bearing (possibly accompanied by loud noise).
- Punctured diaphragm.
- Detective motor.
NOISY
- Check if the mounting feet are compressed too tightly.
- Is the mounting surface flexible? If so, it may be adding noise.
- Check for 100Se head/screws.
- If the pump is plumbed with rigid pipe, then it may transmit noise more easily.
CAUTION
Please do follow the instruction manual to install the product. My action
outside what is recommended In this manual may bring damage to the pump. Any
inappropriate instalabon or operation that causes the pump damage Is not
covered by warranty.