Prescolite LBRP-M-LSSLCS9 Anodized Canless Recessed Downlight Installation Guide

May 15, 2024
prescolite

Prescolite-logo

Prescolite LBRP-M-LSSLCS9 Anodized Canless Recessed Downlight

Product Information

  • Specifications:
    • Product Name: Anodized Canless Recessed Downlight
    • Model Number: PRE_LBRP_inst_R01
    • Material: Anodized Aluminum
    • Colour: Silver
    • Dimensions: 4-inch diameter, 3-inch depth
    • Power: 12W
    • Input Voltage: 120V
    • Lifespan: 50,000 hours

Product Usage Instructions

  • Locate the Installation
    • Locate the installation area on the ceiling where you want to place the recessed downlight.
    • Turn off the power supply to the area where you will be working.
    • Remove the existing light fixture if present.
    • Follow the wiring instructions provided with the downlight to connect it to the electrical system.
    • Gently push the downlight into the ceiling opening until it is flush with the ceiling surface.
    • Secure the downlight in place using the included mounting clips.
    • Turn on the power supply and test the downlight to ensure it is functioning correctly.

Frequently Asked Questions

  • Q: Can this downlight be dimmed?
    • A: Yes, this downlight is compatible with most standard dimmer switches for adjustable brightness.
  • Q: What type of bulb does this downlight use?
    • A: This downlight is integrated with a non-replaceable LED bulb that has a long lifespan.
  • Q: Is this downlight suitable for damp locations like bathrooms?
    • A: Yes, this downlight is rated for damp locations and can be safely installed in bathrooms and kitchens.

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

  • Follow label information and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping.
  • Do not install in areas subject to combustible vapours or gases.
  • Before wiring to the power supply and during servicing or relamping, turn off the power at the fuse or circuit breaker.
  • All servicing or relamping must be performed by qualified service personnel. The product must be grounded to avoid potential electric shock or another potential hazard.
  • Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with the National Electrical Code and local codes.
  • The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from the product in whole or part, as this may cause an unsafe condition.
  • Do not allow items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
  • Fixtures are suitable for use in clothes closets per NEC 410.16(C)(1).
  • Fixtures are not suitable for installation into clothes closet storage spaces as defined by NEC 410.2.

Installation Steps

  • Step 1
    • Before ceiling installation, use the ring located above the lens to select the beam angle desired.
  • step 2
    • Use 1he tables shown in the illustration to adjust the Wattage/Lumen and CCT selector switches to achieve the desired light output and colour temperature.Prescolite-LBRP-M-LSSLCS9-Anodized-Canless-Recessed-Downlight-fig-1 \(2\)
  • Step3
    • Select and install the Reflector Kit chosen from sizes 4″, 6″ or 8″
    • A. Align the notch of the Reflector Kit with the “unlock” position of the Light Engine
    • B. Push the reflector kit down until bottomed out on the light engine
    • C. Turn the Reflector Kit counterclockwise to align the notch into the locked position.Prescolite-LBRP-M-LSSLCS9-Anodized-Canless-Recessed-Downlight-fig-1 \(3\)
  • Step 4
    • For new construction applications, install a new construction plate in the ceiling first.
    • If a new hole is needed, cut the hole according to the downlight cutout dimensions.Prescolite-LBRP-M-LSSLCS9-Anodized-Canless-Recessed-Downlight-fig-1 \(4\)
  • Step 5
    • For either new construction or retrofit installation, attach the carabiner safety lanyard to the existing fixture housing.Prescolite-LBRP-M-LSSLCS9-Anodized-Canless-Recessed-Downlight-fig-1 \(5\)
  • Step 6
    • Remove the faceplate of the existing or newly installed J-Box and punch out the appropriate knockout.
    • Connect the supply wire conduit to the fixture input leads.
    • Make wire connections using the appropriately sized wire nuts.
    • Reattach the J-Box cover when connections are complete.
    • Black ➔ Line (Hot)
    • White ➔ Neutral
    • Green ➔ Ground
    • Purple ➔ 0-10V Dim(+)
    • Gray or Pink ➔ 0-10V Dim(-)
    • For 0-10V dimming only.
  • Step 7
    • Bend and hold the spring clips upward to a vertical position and insert the downlight into the hole or housing in the ceiling.
  • steps 8
    • After the downlight is inside the housing or ceiling, release the spring clips and push the fixture into the ceiling ensuring the fixture is securely seated and flush with the ceiling.
    • NOTE: Rotating the fixture may be necessary to properly engage spring clips.Prescolite-LBRP-M-LSSLCS9-Anodized-Canless-Recessed-Downlight-fig-1 \(7\)
  • Step 9
    • Restore power at the source. Installation is now complete.Prescolite-LBRP-M-LSSLCS9-Anodized-Canless-Recessed-Downlight-fig-1 \(8\)

WARNING! – RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT KIT REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE LUMINAIRE’S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. IA.WARNING! – RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE LUMINAIRE THAT HAS THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWINGS AND WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOT EXCEED THE INPl!T RATING OF THE LUMINAIRE. DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING INSTALLATION. IA.WARNING! – TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS. THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN BY THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in aresidential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment

CONTACT

  • Current
  • 25825 Science Park
  • Beachwood, OH 44122
  • 864-678-1000
  • © 2023 Current Lighting Holdco, Inc. All rights reserved. Information and specifications are subject to change without notice.
  • All values are design or typical values when measured under laboratory conditions.
  • Rev 04/03/23
  • PRE_LBRP_inst_R01

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals