prescolite Liteframe 2.0 Trim Indoor Lighting Instruction Manual

June 9, 2024
prescolite

prescolite-lgoo

prescolite Liteframe 2.0 Trim Indoor Lighting

prescolite-Liteframe-2-0-Trim-Indoor-Lighting-
product

Product Information

Trim Assembly and Light Engine

The trim assembly is an important component of the lighting fixture that helps to secure the fixture to the ceiling. The trim assembly comes in three variations: Standard, Shallow, and LWW. The light engine is also a vital component of the lighting fixture that provides the light source. The installation of the trim assembly and light engine is critical for the proper functioning of the  lighting fixture.

Standard/Shallow/LWW Trim Assembly Installation

1. Install the lower trim assembly to fixture after the housing and light engine assemblies are installed in the finished ceiling by aligning the arrow marks embossed in the cast flange and trim assembly. Insert the springs into the appropriate casting guide for spring alignment and gently push it against the ceiling. Refer to FIG 1.1 & 1.2 for installation guidance.

Standard/LWW Trim Assembly Installation for IP65 Rating

If an IP65 rating is required, follow these steps before installing the shower trim:

  1. Clean the surface of the ceiling where the trim will mount. The surface should be clean, flat, and smooth.
  2. Apply a thin bead of silicone caulk around the top edge of the plastic trim, as shown below. When installing in the ceiling, remove the excess caulk, and wipe smooth to create an attractive seam.
  3. If the surface is textured or uneven (such as tile or stucco), apply sufficient silicone caulk to eliminate gaps. NOTE: Creating a good, complete seal with the silicone caulk is necessary to achieve the IP65 rating.

The following trims can be used for IP65 rated installations:

  • Garniture 4RD-CL
  • Garniture 6RD-CL
  • Garniture 4RD-VNR-CL
  • Garniture 6RD-VNR-CL
  • Garniture 4RW
  • Garniture 6RW

Refer to the product manual for additional installation instructions and guidance.

IMPORTANT SAFETY INFORMATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

INSTALLATION INSTRUCTIONS

Standard/Shallow/LWW Trim Assembly Installation:

  1. Install the lower trim assembly to fixture after the housing and light engine assemblies are installed in the finished ceiling by aligning the arrow marks embossed in the cast flange and trim assembly. Insert the springs into the appropriate casting guide for spring alignment and gently push it against the ceiling. FIG 1.1 & 1.2.prescolite-Liteframe-2-0-Trim-Indoor-Lighting-fig 1

Standard/LWW Trim Assembly Installation for IP65 Rating:

If the IP65 rating is needed for the installation, follow the below steps before installing the shower trim as described in page 1,

  • A. Clean the surface of the ceiling where the trim will mount. The surface should be clean, flat, and smooth.
  • B. Apply a thin bead of silicone caulk around the top edge of the plastic trim, as shown below. When installing in the ceiling, remove the excess caulk, and wipe smooth to create an attractive seam.
  • C. If the surface is textured or uneven (such as tile or stucco) apply sufficient silicone caulk to eliminate gaps.
    NOTE: Creating a good, complete seal with the silicone caulk is necessary to achieve the IP65 rating.prescolite-Liteframe-2-0-Trim-Indoor-Lighting-fig
2

Adjustable Trim Assembly installation:

  1. Install the lower trim assembly after the housing and light engine assemblies are installed in the finished ceiling and the light engine assembly adjustment has been aimed and locked into the desired position. Ensure the upper optic is properly seated to the LED holder and has not become dislodged during shipping or installation/adjustment of the fixture. Press both springs upwards and insert into the appropriate casting guide for spring alignment and gently push it against the ceiling.prescolite-Liteframe-2-0-Trim-Indoor-Lighting-fig 3

currentlighting.com/Prescolite
© 2021 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

  • Assistance technique de Prescolite au numéro sans frais 1.888.PRS.4TEC • Heures: 8 h 00 à 17 h 00 HNE

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

prescolite User Manuals

Related Manuals