INKBIRDPLUS 1800W Heat Mat Thermostat Temperature Controller User Manual

May 15, 2024
INKBIRDPLUS

THERMOSTAT TIMING SOCKET T01
USER MANUAL

Introduction

This timing socket comes with an external detecting probe to detect the temperature. It can set the opening temperature and closing temperature, and has the functions of cycle timing, timing opening, timing closing, timing opening and closing. It is widely used  in the intelligent control of carbon crystal heating, aquaculture, greenhouse, home life, and other places.

Screen Display Precautions

  • Real-Time Temperature Range: -40℃~120℃
  • When the circuit is open (or when the temperature is less than -45℃), the first line of the screen flashes and displays “E1”, and it displays -40 ℃ when the temperature is between -40℃ to -45℃.
  • When the circuit is short (or when the temperature is more than 120℃), the first line of the screen flashes and displays “E2”, and it displays 120℃ when the temperature is between 121℃ to 129℃.
  • When the temperature is low than -10℃ or higher than 100℃, it will not display the value after the decimal point.
  • When the set start temperature is higher than the stop temperature, the device is in cooling mode, and the corresponding icon will be displayed as.
  • When the set start temperature is lower than the stop temperature, the device is in heating mode, and the corresponding icon will be displayed as.

Operation Instruction

INKBIRDPLUS 1800W Heat Mat Thermostat Temperature Controller - Operation
Instruction

  • MODE Button (MODE):
    Press the MODE button to switch between Temperature Control Mode and Timing Mode F01~F04.
    INKBIRDPLUS 1800W Heat Mat Thermostat Temperature Controller - MODE
ButtonF01 Cyclic Timing Mode: Cycle by start time (ON) and stop time (OFF).
    F02 Count Down ON Mode: It’s currently in the OFF state, and the delay is on.
    F03 Count Down OFF Mode: It’s currently in the ON state, and the delay (stop time) is off.
    When the stop time countdown is complete, turn off the output and exit the running state.
    F04 Count Down ON & OFF Mode: It’s currently in the OFF state, and the delay (start time) is on. After starting, the delay (stop time) is turned off. When the stop time countdown is complete, turn off the output and exit the running state.
    Note:
  1. In the timing mode, when the start time/stop time is 0, no opening or closing will occur, and the corresponding time will flash to alarm.
  2. The running state prohibits switching the timing mode.
    Press and hold the MODE button for 3 seconds to switch between Startup and Shutdown, and the corresponding mode icon will flash after power on.
  3. In temperature control mode, the or icon blinks (depending on whether it is in heating or cooling mode).
  4. In the timing mode, the ON/OFF character of the current running mode blinks, the time symbol “:” blinks, and the time runs at the same time. After the device starts and runs to ON, the relay closes and the socket output indicator lights up. When it runs  to OFF, the relay is disconnected and the indicator light is off.
  • SET Button (SET)
  1. In temperature control mode, press the SET button to set the start temperature and stop temperature, ranging from -40℃ to 120℃. (The default start temperature is 20℃, and the stop temperature is 25℃.)
  2. In timing mode F01~F04, press the SET button to set start hours/minutes and stop hours/minutes, ranging from 0 to 99 hours and 59 minutes.
  3. Under the running state, temperature and time can be adjusted through the SET button.
  • UP/DOWN Button
  1. When the numeric value is flashing, press the UP or DOWN button to adjust the value.
  2. Press the UP or DOWN button to add or subtract one value. Long pressing will automatically add and subtract values.
  3. Under the non-running state, press and hold the UP and DOWN buttons simultaneously for 3 seconds to restore the factory settings.

Temperature Calibration Function

  1. After power on, press and hold the MODE button for 2 seconds to calibrate the real-time temperature. The first line of the screen will display “CALIBRATION” and the real-time temperature, and the calibration value on the second line will flash. Press the  UP or DOWN button to adjust the calibration value. (After adjusting the calibration value, the real-time temperature will change accordingly.)
  2. Real-Time Temperature Calibration Range: -9.9℃~9.9℃.
  3. Long pressing the SET button to exit (or automatically exiting after 5 seconds of no operation) will not save the modification. Long press the MODE button to exit and save the modification.

℃ or ℉ Selection

Press and hold the SET button for more than 5 seconds to switch between ℃ or ℉.

Backlight Mode (This feature is limited to the backlit version)

Turn on the AC power, and the backlight will turn on immediately. If no button is pressed, the backlight will turn off after 10 minutes. Press any button to turn the backlight on again.

Memory Function: All current settings will be saved after power off.

Factory Test

Press the RESET button with a sharp point to turn on the screen for one second and restore the factory settings.

Technical Parameters:

EU FR PLUG: 16(2)A 230V~ Max.3680W.u
UK PLUG: 13(2)A 230V~ Max.2900W.u
AU PLUG: 10(2)A 240V~ Max.2400W.u
US PLUG: 15(2)A 120V~ Max.1800W.u
Temperature Range: -40℃~120℃
Temperature Control Accuracy: ±1%
Timing Accuracy: Max. 10 minutes

support@inkbird.com
0755-25721303
www.inkbird.com
18th Floor, Guowei Electronic Commercial Mansion,
NO.68 Guowei Rd, Xianhu Community,
Liantang, Luohu District, Shenzhen, Guangdong Province, China