MITSUBISHI ELECTRIC TPLA0A0361EA70B Ceiling Cassette Instruction Manual

May 15, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC TPLA0A0361EA70B Ceiling Cassette

Product Usage Instructions

Installation

  1. Ensure proper electrical supply and wiring before installation.
  2. Mount the indoor unit in the ceiling cassette according to the provided dimensions.
  3. Connect the refrigerant piping following the specified pipe sizes and guidelines.

Operation

  1. Power on the unit using the remote controller or control interface.
  2. Select the desired cooling or heating mode and set the temperature accordingly.
  3. Adjust fan speed and airflow direction for optimal comfort.

Maintenance

  1. Regularly clean the air filters to ensure efficient operation.
  2. Check for any leaks in the refrigerant piping and repair if necessary.
  3. Schedule annual professional maintenance to keep the unit in top condition.

FAQ

  • Q: Can I use a wireless remote controller with this indoor unit?
  • A: No, the indoor unit is compatible only with the wired remote controller provided (PAC-SF40RM-E).
  • Q: What is the recommended ceiling height for installation?
  • A: The ceiling height should be at least 70-7/8 inches (1800mm) or more from the floor for proper installation.
  • Q: How often should I clean the air filters?
  • A: It is recommended to clean the air filters every 2-4 weeks depending on usage to maintain optimal performance.

GENERAL FEATURES

  • Space-efficient ductless installation
  • Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
  • Airflow settings for high and low-ceiling applications
  • Individual vane settings for direct/indirect airflow control or variable airflow patterns
  • Knockouts for outside-air intake and branch-duct run
  • Filter indicator signal
  • Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
  • Built-in condensate lift mechanism
  • Ideal for retail shops, classrooms, office spaces, conference centres, building lobbies, and more
  • Multiple control options available:
    • Kumo cloud® smart device app for remote access
    • Third-party interface options
    • Wired or wireless controllers

Specifications

Specifications System
Unit Type TPLA0A0361EA70B
Cooling Capacity1, 3 BTU/H
Heating Capacity2, 3 BTU/H

Electrical

| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198- 253V
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5

Indoor Unit

| MCA| A| 2.0
Fan Motor Full Load Amperage| A| 0.95
Airflow Rate at Cooling, Dry| CFM| 670–850–1,020–1,200
Airflow Rate at Cooling, Wet| CFM| 630–810–980–1,160
Airflow Rate at Heating, Dry| CFM| 670–850–1,020–1,200
Sound Pressure Level [Cooling]| dB[A]| 32–37–41–44
Sound Pressure Level [Heating]| dB[A]| 32–37–41–44
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [849]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 11-3/4 // 1-9/16 [840 // 950 x 840 //

950 x 298 // 40]

Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 16-9/16 // 4-12/16 [903 // 1,000 x 871

// 970 x 421 // 121]

Unit Weight| Lbs. [kg]| 56 // 11 [25 // 5]
Package Weight| Lbs. [kg]| 77 [35]
Refrigerant| Type| R410A

Piping

| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]

NOTES
Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance.

INDOOR UNIT ACCESSORIES

INDOOR UNIT ACCESSORIES: TPLA0A0361EA70B

Control Interface

| 3-Pin Connector| □ PAC-715AD
---|---|---
Airline ZBS Wired Blueface Principal Controller White| □ AZZBSBLUEFACECB
Airline ZBS Wired Lite Controller White| □ AZZBSLITECB
Airline ZBS Wireless Lite Controller White| □ AZZBSLITERB
Airline ZBS Wireless Think Controller White| □ AZZBSTHINKRB
BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
CN24 Relay Kit| □ CN24RELAY-KIT-CM3
IT Extender| □ PAC-WHS01IE-E
Kumo station® for kumo cloud®| □ TAC-WHS01HC-E
Remote Operation Adapter‡| □ PAC-SF40RM-E
Thermostat Interface| □ PAC-US445CN-1
USNAP Adapter| □ PAC-WHS01UP-E
Wireless Interface for Kumo cloud®| □ PAC-USWHS002-WF-2

Remote Sensor

| Flush Mount Remote Temperature Sensor| □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor| □ PAC-USSEN001-FM-1
Remote Temperature Sensor| □ PAC-SE41TS-E
Wireless temperature and humidity sensor for Kumo cloud®| □ PAC-USWHS003-TH-1

Wired Remote Controller

| Deluxe Wired MA Remote Controller†| □ TAR-40MAAU
Simple MA Remote Controller†| □ TAC-YT53CRAU-J
Touch MA Controller†| □ TAR-CT01MAU-SB

Wireless Remote Controller

| Kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Lockdown bracket for remote controller| □ RCMKP1CB
Wireless MA Receiver| □ PAR-SR32MA-E
Wireless MA Remote Controller| □ TAR-FL32MA-E
Wireless Remote Contoller| □ PAR-SL101A-E
Wireless Signal Receiver Panel| □ PAR-SR4LU-E
Casement| Multi-function Casement| □ PAC-SJ41TM-E

Condensate

| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]| □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor| □ X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI

Disconnect Switch

| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ TLP-41EAEU

Lineset

| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E

NOTES
‡PAC-SF40RM-E (Unable to use with wireless remote controller)

DIMENSIONS

INDOOR UNIT DIMENSIONS: TPLA0A0361EA70B

NOTE

  1. CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.

  2. REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE RESISTANCE AS NEEDED.

  3. FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.)

  4. FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4″(( 32) PVC TUBE). DRAIN PUMP INCLUSION.
    RAISE IS-MAX 33-7/16″(850mm) FROM THE CEILING.

  5. ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE A LITTLE BIT FOR THE CONTROL/POWER WIRE CONNECTION.

  6. THE HEIGHT OF THE INDOOR UNIT CAN BE ADJUSTED WITH THE GRILLE ATTACHED.

  7. REQUIRES “E” OR MORE SPACE BETWEEN THE TRANSOM AND CEILING FOR THE INSTALLATION.

  8. WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)

  9. AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.

  10. FOR THE INSTALLATION OF THE OPTIONAL HIGH-EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT, REFER TO SPECIAL DRAWING.

MITSUBISHI-ELECTRIC-TPLA0A0361EA70B-Ceiling-Cassette-
FIG-1

© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals