MITSUBISHI ELECTRIC TPKA0A0121LA10A Split System Heat Pump Wall Mounted Indoor unit Instruction Manual

May 15, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC TPKA0A0121LA10A Split System Heat Pump Wall Mounted

Indoor unit

MITSUBISHI-ELECTRIC-TPKA0A0121LA10A-Split-System-Heat-Pump-Wall-Mounted-
Indoor-unit-produvt

Specifications

  • Product: Mitsubishi Electric Trane HVAC US Split-System Heat Pump
  • Model Name: TPKA0A0121LA10A, TPKA0A0181LA10A
  • Parts Catalog No.: TCBT012
  • Published: February 2023

Product Usage Instructions

Installation

  1. Refer to the service manual (TCHT012) for detailed installation instructions.
  2. Ensure all parts listed in the service parts list are present before starting the installation.
  3. Follow the wiring diagram symbols for proper connection of parts.

Maintenance

  • Regularly clean the air filter (Part No. 7) for efficient operation.
  • Inspect and clean the indoor coil thermistor (Part No. 6) periodically.
  • Check the electrical cover (Part No. 14) and box (Part No. 15) for any signs of damage.

Operation

  • Use the wireless remote or wired remote controller for operating the heat pump.
  • Ensure proper placement of the remote sensor for accurate temperature readings.
  • Familiarize yourself with the menu options for setting preferences.

FAQ

  • Q: Where can I find replacement parts for the heat pump?
    • A: You can refer to the service parts list in the manual for part numbers and contact Mitsubishi Electric Trane HVAC US for replacements.
  • Q: How often should I clean the air filter?
    • A: It is recommended to clean the air filter every 1-2 months depending on usage and air quality.
  • Q: Can I install the heat pump without professional assistance?
    • A: It is recommended to have a professional HVAC technician install the heat pump to ensure proper installation and performance.

PARTS

MITSUBISHI-ELECTRIC-TPKA0A0121LA10A-Split-System-Heat-Pump-Wall-
Mounted-Indoor-unit-fig \(1\)

SERVICE PARTS LIST

PANEL AND HEAT EXCHANGER PARTS

  • TPKA0A0121LA10A
  • TPKA0A0181LA10AMITSUBISHI-ELECTRIC-TPKA0A0121LA10A-Split-System-Heat-Pump-Wall-Mounted-Indoor-unit-fig \(2\)
  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure

No.

|

Parts No.

|

Parts Name

| TPKA0A0121LA10A| TPKA0A0181LA10A|

Wiring Diagram Symbol

|

Remarks

---|---|---|---|---|---|---
1| E27 P68 970| INSTALLATION PLATE| 1| 1|  |
2| E27 P68 234| BOX ASSEMBLY| 1| 1|  |
3| E 27 Y98 976| CORNER BOX L| 1| 1|  |
4| E 27 Y98 975| CORNER BOX R| 1| 1|  |
5| E27 21F 620| INDOOR HEAT EXCHANGER| 1| 1|  |
6| E27 13D 307| INDOOR COIL THERMISTOR| 1| 1| TH2, TH5|
7| E27 58G 100| AIR FILTER| 2| 2|  |
8| E27 P63 021| ARM HOLDER SET| 1| 1|  | set (left, right)
9| E27 10A 010| FRONT PANEL| 1| 1|  |
10| E22 F95 142| CATCH| 2| 2|  | 2 pcs/set
11| E22 98B 067| SCREW CAP| 2| 2|  | 2 pcs/set
12| E27 10A 000| PANEL ASSEMBLY| 1| 1|  | Includes 8, 9, 10, 11

FAN AND ELECTRICAL PARTS

  • TPKA0A0121LA10A
  • TPKA0A0181LA10A

MITSUBISHI-ELECTRIC-TPKA0A0121LA10A-Split-System-Heat-Pump-Wall-Mounted-
Indoor-unit-fig \(3\)

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.

|

Parts No.

|

Parts Name

| TPKA0A0121LA10A| TPKA0A0181LA10A|

Wiring Diagram Symbol

|

Remarks [Drawing No.]

---|---|---|---|---|---|---
1| E2 2| T20| 7 0 2| DRAIN HOSE| 1| 1|  |
2| E27| 42R| 705| DRAIN CAP| 1| 1|  |
3| E27| 77G| 235| NOZZLE ASSEMBLY| 1| 1| | Full assembly except drain hose
4| E27| 103| 303| VANE MOTOR (UPPER)| 1| 1| MV1|
5| E22| Y54| 303| VANE MOTOR (LOWER)| 1| 1| MV2|
6| E27| 77G| 040| VANE UPPER| 1| 1|  |
7| E27| 77G| 041| VANE LOWER| 1| 1|  |
8| E2 7| 2 1F| 3 7 5| TERMINAL BLOCK| 1| 1| TB4|
9| E27| 249| 375| TERMINAL BLOCK| 1| 1| TB5|
10| E27| P63| 308| ROOM TEMP. THERMISTOR| 1| 1| TH1|
11| E27| Y99| 468| DISPLAY AND RECEIVER P.C. BOARD| 1| 1| L.B., W.B., S.B.|
12| E27| P63| 095| DISPLAY RECEIVER HOLDER| 1| 1|  |
13| E27| 58R| 447| INDOOR CONTROLLER BOARD| 1| 1| I.B.|
14| E27| P63| 333| MOTOR BAND| 1| 1|  |
15| E27| P63| 541| WATER COVER| 1| 1|  |
16| E27| P64| 333| MOTOR BED| 1| 1|  |
17| E27| 13D| 300| INDOOR FAN MOTOR| 1| 1| MF| Includes rubber mounts
18| E27| P68| 302| LINE FLOW FAN| 1| 1|  |
19| E22| A89| 509| BEARING MOUNT ASSEMBLY| 1| 1|  |
20| E27| Y98| 978| CONDUIT PLATE SET| 1| 1| |
21| E22| C32| 667| UNION 1/4″| 1| 1|  | for liquid
22| E22| 179| 667| UNION 1/2″| 1| 1|  | for gas

OPTIONAL PARTS

Parts name Parts No.
Wired Remote Controller TAR-41MAA, TAC-YT53CRAU
Wireless remote controller PAR-SL101A-E
External Drain pump kit PAC-SK01DM-E
Remote Sensor PAC-SE41TS-E
Connector cable for Remote Display PAC-SA88HA-EP
Heater control relay adapter PAC-SE56RA-E

MITSUBISHI ELECTRIC TRANE HVAC US LLC

HEAD OFFICE: 1340 SATELLITE BOULEVARD, SUWANEE, GA 30024, USA

MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD. 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000 THAILAND Published: Feb. 2023 No. TCBT012 Made in Thailand

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals