AMPTRON AT-LFP-12-200-BTC-DV10 12V 200AH Slimline Lifepo4 Bluedge Battery User Manual
- May 15, 2024
- AMPTRON
Table of Contents
- AMPTRON AT-LFP-12-200-BTC-DV10 12V 200AH Slimline Lifepo4 Bluedge Battery
- Product Usage Instructions
- Specifications
- Product Registration
- Warnings & Tools Icon Chart
- Charging Specific Advice
- Storage Advice
- Parallel Battery Connection
- Series Battery Connection
- Bluetooth Smartphone Application
- App Download Instructions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AMPTRON AT-LFP-12-200-BTC-DV10 12V 200AH Slimline Lifepo4 Bluedge Battery
Specifications
- Model: AT-LFP-12-200-BTC-DV10
- Size: 430 L x 120 W x 270 H (mm)
- Weight: 23kg
- Connection Terminals: M8
- Connection Terminals Torque Rating: 6Nm
- Casing Material: Aluminium
- Chemistry: Lithium Iron Phosphate (LiFePO4)
- Cell Type: Prismatic
- Rated Capacity: 200Ah / 2560WH (at 0.2C)
- Battery Packs in Series: Supported (4)
- Battery Packs in Parallel: Supported
- Battery Cycle Life: 6000 times (0.2C standard charge and discharge)
- Rated Voltage / Nominal Voltage: 12.8V
- Operating Voltage Range: 10V – 14.6V
- Shipping Voltage: 11 – 14V
- Max Charge Voltage: 14.6V (3.65V per cell)
- Cut-off Voltage: 10V / When lowest cell reaches 2.5V
- Depth of Discharge (DoD): 100%, Recommended DoD 80%
- Standard (Recommended) Charge Current: 40A
- Charging Time (At recommended charge current): 4-5 Hours
Product Usage Instructions
Electrical Information
- Circuit Protection:
- Maximum charge current: 3
- Max continuous discharge current: 80A
- Peak discharge current (3 seconds): 100A
- Internal resistance: 4mΩ
- Operating power consumption: Refer to the specification
- Operating temperature: Refer to specifications
- Recommended storage temperature: Refer to specifications
- Recommended storage humidity: Refer to specifications
- Recommended storage duration: Refer to specifications
- Cell overcharge protection: Yes
- Cell over-discharge protection: Yes
- Charging over current protection: Yes
- Discharging over current protection: Yes
- Short circuit protection: Yes
- High-temperature discharge/charge protection: Yes
- Low-temperature discharge/charge protection: Yes
Recommended Tools and Accessories
- Wire cutter
- Multimeter
- Anti-static glove
- Electrical tape
- Screwdriver
- Torque wrench
DC Wire Sizing Guidelines
Amps | Wire Cross Section Area (mm) | Wire AWG |
---|---|---|
40A | 10 | 8 |
Frequently Asked Questions (FAQ)
- Q: What is the recommended storage duration for the product?
A: The recommended storage duration is as per the specifications provided, ensuring optimal performance and longevity of the battery.
“We may modify these specifications without prior notice.
Specifications
MODEL: AT-LFP-12-200-BTC- DV10
Physical
| Size| 430 L x 120 W x 270 H (mm)
Weight| 23kg
Connection terminals| M8
Connection terminals torque rating| 6Nm
Casing material| Aluminium
Chemistry| Lithium iron phosphate (LiFePO4)
Cell type| Prismatic
Electrical
| Rated capacity| 200Ah / 2560WH (at 0.2C)
Battery packs in series| Supported (4)
Battery packs in parallel| Supported
Battery cycle life (charge & discharge once is one cycle)| 6000 times (0.2C
standard charge and discharge)
Rated voltage / nominal voltage| 12.8V
Operating voltage range| 10V – 14.6V
Shipping voltage| 11 – 14V
Max charge voltage| 14.6V (3.65V per cell)
Cut-off voltage| 10V / When a lowest cell reaches 2.5V
Depth of discharge (DoD)| 100%, Recommended
DoD 80%
Standard (Recommended) charge current|
40A
Charging time (At recommended
charge current)
|
4-5 Hours
Electrical Cont.
| Maximum charge current| 200A
---|---|---
Max continuous discharge current| 200A
Peak discharge current (3 seconds)| 400A
Internal resistance| ≤ 12mΩ
Environmental
| Operating power consumption| ≤ 25mA
Operating temperature| -5°C~ 55°C
Recommended storage temperature| 10°C~ 35°C
Recommended storage humidity| 10% – 90%
Recommended storage duration| Charge to 13.3V
OR 40 – 60% SOC every
6 months
Circuit Protection
| Cell overcharge protection| 3.65V±0.05V
Cell over-discharge protection| 2.5V±0.1V
Charging over current protection| 210A (30s)
Discharging over current protection| 1st 210A (30s)
2nd 440A (1s)
Short circuit protection| 1000A (400us)
High-temperature discharge/charge protection|
60°C±5°C
Low-temperature discharge/charge protection|
-10±5°C
Thank you
Dear valued customer,
Thank you for choosing Amptron Batteries. We greatly appreciate your support.
Our team works behind the scenes to create advanced battery systems while
providing top-notch Australian-based service to our customers. Support and
feedback from our customers, along with the dedication of our staff, allows us
to deliver exceptional products, competitive prices, and an overall excellent
experience. Thanks again for giving us your vote of confidence. We hope that
you’ll enjoy using our products as much as we’ve enjoyed creating them. Please
feel free to reach out to us anytime.
Sincerely,
Amptron
Product Registration
We offer warranty coverage for all of our battery systems. To register your
product, visit https://amptron.au/product-registration and include your
proof of purchase to simplify any future warranty claim.
Please fill out the below information for your own record-keeping:
The latest warranty statement and additional warranty information can be found on our website by visiting: https://amptron.au/warranties
Warnings & Tools Icon Chart
Wire Sizing Recommendations
Please see our recommendations for cable sizing below.
WARNING!
Incorrectly sizing your cables can result in damaged equipment and fire
hazards. For more information, please see AS/NZS 3008.1:2017, or consult with
an expert.
DC WIRE SIZING| 40A| 60A| 80A| 100A| 120A|
140A +
---|---|---|---|---|---|---
Wire cross-section area (mm)| 10| 16| 25| 25| 35| 50
Wire AWG| 8| 6| 4| 4| 2| 1
The above recommendation is based on cable lengths Ofo- 1.8m. If the cable is longer than this, go to the next AWG size for every 1.8m added length.
Warnings!
Review this manual thoroughly before attempting installation. Failure to
follow these safety guidelines can result in property damage, personal injury,
or worse.
- If damaged upon arrival, please contact the vendor for product support.
- Beware of any nearby electrical equipment that may interfere with installing this device.
- If using solar panels to charge the battery, ensure they are isolated, or covered, before connecting to the battery.
- If connecting to a DC/DC charger to charge the battery, ensure that the charger is disconnected or isolated from the house/starter battery before connecting it.
- Do not be exposed to heat, high voltage and direct sunlight.
- Do not short-circuit the positive and negative terminals.
- Do not store the battery along with metal and other conductive materials.
- Do not disassemble the battery.
- Do not knock, throw or impact the battery.
- Do not throw the battery into the water.
- Do not install in under bonnet applications.
- Do not install in an engine starting application.
Charging Specific Advice
- To maximize safety, it is recommended to not charge when the site is unattended.
- When charging, keep the battery in a well-ventilated, dry, free Of inflammable and explosive materials, and out Of reach Of children.
- Always use a battery charger with a lithium profile that does not exceed the charging specifications of the battery (see page 3).
- If you are unsure about which charger to use, please contact Amptron and consider our charger range designed for the batteries.
- The charger must not have an equalization setting enabled. If this can be disabled then it needs to be turned Off.
- When the battery leaves the factory, there is only around 30% capacity in the battery due to freight regulations, please charge the battery before use.
Discharge Specific Advice
- If the battery cuts out on low voltage, disconnect the load, and charge the battery before reconnecting the load. Depending on the charger brand and model, you may need to apply a secondary source of 12V-14.6V to the terminals to reset the BMS.
- A low-voltage cut-off device is strongly recommended if your inverter/loads do not have a low-voltage cut-off. Set to the voltage as shown on page 2 of this manual.
- If the battery goes below the over-discharge protection voltage (as indicated on page 3) or the over-discharge protection is activated, charge a battery within 15 days.
Storage Advice
- The battery should be charged every 6 months.
- Ideally, before storage, charge the battery to 70% SOC.
- The ideal storage temperature is 200C – 350C.
- DO not leave a battery in a low state Of charge for long periods.
- If the battery shows signs of deformation, or heat or emits a smell, immediately discontinue use.
Parallel Battery Connection
For detailed instructions on connecting multiple batteries in parallel, please see our white paper on the topic via the support section of our website.
- 1. Ensure all batteries in the parallel configuration have been fully charged individually by the same charger.
- Ensure the OCV of each battery is within <0.2V of each other.
- After charging, set aside and allow to rest for 2-3 hours.
- Utilizing wires of circumference large enough to carry the required current, connect the batteries in the above configuration.
- Ensure all connecting cables are of the same length.
- Be careful not to reverse-connect the positive and negative.
- Ensure correct charge voltage and current are utilized for configuration.
- It is prohibited to series a paralleled configuration.
- Once in parallel configuration, ensure a full charge is completed a minimum Of every 3 months.
- Once in parallel, the ‘system’ must be charged and discharged as if it were a single battery.
Series Battery Connection
Maximum 4 Batteries For detailed instructions on connecting multiple batteries in series, please see our white paper on the topic via the support section of our website.
- Up to four batteries can be connected in series for higher voltage applications. Alternatively, select a higher voltage battery that Amptron has available.
- Ensure all batteries in the series configuration have been fully charged individually by matched chargers.
- Ensure the OCV of each battery is less than <O.2V of each other.
- After charging, set aside and allow to rest for 2-3 hours.
- Utilizing wires Of circumference large enough to carry the required current, connect the batteries in the above configuration. Ensure all connecting cables are of the same length.
- Be careful not to reverse-connect the positive and negative.
- Ensure correct charge voltage and current is utilized for configuration: a) Two batteries in series: 28.4V to 29.2V, recommended 28.6V b) Three batteries in series: 42.6V to 43.8V, recommended 42.9V c) Four batteries in series: 56.8V to 58.4V, recommended 57.2V
- Once in a series configuration, ensure a full charge is completed a minimum of every 3 months.
- Once in a series configuration, the ‘system’ must be charged and discharged as if it were a single battery.
- Consider additional balancers to maintain the individual voltage levels of the batteries. Please get in touch with us for recommended options.
Bluetooth Smartphone Application
Key Features
Available as an ad-free download via App Store & PlayStore, currently this
is a third party App whilst Amptron develops its own cross-platform app. The
app offers convenient access to battery system data, including:
This app may look different based on your phone and/or app version.
- Cycle count
- Current (amperage)
- State of Health (SOH)
- State of charge (SoC)
- Temperatures (for each temperature sensor)
- Voltage (minimum, maximum, and average)
- Capacity (design capacity & actual capacity)
- Alerts for safety features and protections
App Download Instructions
- Install the application using the above QR code links.
- Open the app and ensure permissions are granted if asked.
- Under the list of devices, click on the device with ID starting with AT.
- Your phone once successfully connected to the device, will show the information.
Communication Port Instructions
- Along with Bluetooth, your battery is fitted with communication ports which can be used for standalone communication with a compatible inverter or smart device.
- If your installation needs to be compliant with AS/NZS 3001.2.2022, then contact Amptron for advice on meeting the monitoring requirements.
- The data port connection is located between the positive and negative battery terminals. This terminal supports both serial RS485 and CANBUS, depending on your requirements.
Data Port Connection For RS4851 CANBUS.
Please contact Amptron support for a pin-out diagram, communication protocols,
and cable options.
@Amptron Technology Group 2023
Any use in full or in part of this user manual must include attribution.
p: 1300 543 376 | e: info@amptron.com.au /w:
amptron.au