DIMENSIONS AND TECHNICAL SPECIFICATIONS

Dimensions
Unit of measurement: mm ![DAN DRYER 3192 Column Large Capacity Hand Sanitiser

TECHNICAL SPECIFICATIONS

DESCRIPTION DATA
Material Steel
Voltage (adapter version) 6V DC, 230VAC/6VDC adapter included
Voltage (battery version) 6V DC, battery box (included) for 4x D-type LR20

batteries (not included)
Sensor type| Infrared, self-adjusting
Sensor range| Preset at 100 mm
Dosage amount| 1-1.2 ml (4100-5000 activations / 5 litre bottle)
Pump life| 100,000 activations
Mechanism life| 500,000 activations
Bottle| 5 I
Net weight| 17.1 kg
Gross weight| 19.6 kg

PRODUCT TYPE / MODEL

Adapter
3192 Sanitiser stand, white
3193 Sanitiser stand, black
3194 Sanitiser stand, RAL Classic
Battery
3196 Sanitiser stand, white
3197 Sanitiser stand, black
3198 Sanitiser stand, RAL Classic

GENERAL SAFETY INFORMATION

WARNING

  • Turn off the power to the unit before servicing or cleaning
  • Never make alterations to the product
  • Never insert objects into any opening in the product
  • The product is not intended for playing purposes
  • Cleaning and maintenance only by qualified persons
  • The product may only be used for the applications described in this manual
  • Do not use any accessories not recommended by the manufacturer
  • The product should be checked on a regular basis. Never use a defective or malfunctioning unit
  • Never make alterations to the product affecting its performance. DAN DRYER’s product warranty does not cover product problems that result from misuse or alteration

NOTE
If the power cord is damaged, it must be replaced immediately. Disconnect the electricity supply cord according to instructions.
This product is not intended for use by persons (inclusive children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they are
supervised or have been given instructions concerning use of the product by a person responsible for their safety.
Children should be supervised to ensure this product is used correctly.

INSTALLATION

Make sure the main breaker is turned off. Installation must be carried out by a qualified person in accordance with applicable standards in the country concerned.

  1. Use the special key supplied to open the door.

  2. Pull wire, plastic tube, and faucet coupling through the hole in the top plate.

  3. Pull the tube and wire through the rubber gasket, nylon bushing, and clamping nut.
    DAN DRYER 3192 Column Large Capacity Hand Sanitiser -
bushing

  4. Place the faucet in the center before tightening the nut. Do not use any tools.

  5. Attach the transparent plastic hose to the pump nozzle piece.

  6.  Pay attention to power plug orientation pin.

  7. Connect the plugs on the wires between faucet and the control box.

  8. Insert drip tray in the support rails, lengthwise, under the top plate. ADAPTER (MODEL 3192-3194)

  9. 1A) Connection with an adapter. Push the cable through the cable lead-in at the bottom of COLUMN. ADAPTER (MODEL 3192-3194)
    9,2A) Push cable further upward and through the ’rack’. BATTERY (MODEL 3196-3198)
    9,1B) Connect to the external battery box. Install the battery box on the backplate bracket in the lower storage space. Tighten using the butterfly nut. BATTERY (MODEL 3196-3198)
    9,2B) Push cable through the rack via the cable lead-in.

  10. Power connection to box. Connect plug to the control box.

  11.  Take off 5 litre bottle screw lid. We recommend you drill a Ø7 hole for the hose. Or remove the lid completely.

  12. Place the 5 litre bottle on the rack. Insert the tube through the hole in the lid and into the bottle.

  13.  Close front cover and the unit is ready for use.

REPLACEMENT OF BATTERIES AND PUMP

  1.  Open the battery pack with a screwdriver PH2.
  2.  Replace (4) D batteries in the battery pack.
  3. Replacement of pump unit. Remove the tube from the pump unit.
  4. Detach clip from hooks as shown.
  5. Remove the existing pump unit.
  6. Insert new pump. Make sure the pump guideways fit those of the control box. See illustrations.
  7. Attach the clip on the hooks as shown.
  8.  Attach tube to the new pump unit.

PRODUCT APPLICATION

  • Place hands approx 2-10 cm under the sensor to activate the dispenser. The dispenser will release 1-1.2 ml. disinfectant gel

  • Move hands away after disinfectant release

  • Stops automatically when hands are moved away
    IMPORTANT!

  • Ensure easy access to cleaning and maintenance of the product

  • Do not bend the plastic tube too sharp. It will cause reduced dosage or total block total blockage in ture

  • Ensure the unit is placed on a firm and stable base

LIGHT INDICATOR (ADAPTER)

Standby Red light
Active Greenlight
Obstruction of sensor Flashing green and red light

LIGHT INDICATOR (BATTERIES)

Standby No light
Active Greenlight
Obstruction of sensor Flashing green and red light

CLEANING AND MAINTENANCE

Routine cleaning and maintenance is recommended

REPLACEMENT OF DISINFECTANT BOTTLE

  • Use the key supplied to open the door
  • Remove the empty bottle from the rack
  • Replace with the new bottle
  • Insert the pump tube into the bottle
  • Close the door

CLEANING AND MAINTENANCE OF THE CONTROL BOX

  • Cut the power
  • Remove any dust and dirt
  • Do not rinse with running water
  • Use a damp cloth and mild cleaning solution. Never use cleaning detergents with an abrasive effect

CLEANING AND MAINTENANCE OF TAP/SENSOR

  • Do not rinse with running water
  • Use a damp cloth and mild cleaning solution. Never use cleaning detergents with an abrasive effect
  • Clean the sensor for dust and dirt to prevent unintentional activation

TROUBLESHOOTING AND CORRECTIVE ACTIONS

SYMPTOM POTENTIAL CAUSE CORRECTIVE ACTION
No disinfectant is delivered Low supply Refill the disinfectant bottle
The sensor window is dirty Clean the sensor window
Obstruction in front of the sensor window Remove the obstruction
Damaged sensor Contact DAN DRYER for advice
Tube disconnected from the pump If the end of the tube is damaged, please

remove the damaged part. The undamaged tube is to be mounted on the nozzle exit of the pump
Sensor cabling disconnected from control box| Check that the cable from the faucet is installed correctly in the control box
The power supply has been disconnected| Check that the cable from the adapter or the external battery box is installed correctly in the control box (see page 7)
AC/DC adapter not connected| Check that the AC/DC adapter is plugged into the wall and is getting power
The dispenser activates unintentionally| The sensor window is dirty| Clean the sensor window
Obstruction in front of the sensor window| Remove the obstruction
| Damaged sensor| Contact DAN DRYER for advice

PARTS LIST

No. Description
1 Faucet complete
2 End piece
3 Rubber ring
4 Holder for LED print and sensor
5 Rubber gasket (top)
6 Rubber gasket (bottom)
7 Nylon bushing
8 Clamping nut
9 Tube/nozzle connecting part
10 Nozzle for disinfectant
11 Tube 700mm
12 Control box (DC)
13 Pump for disinfectant
14 AC/DC adapter
15 External battery box
16 Lock complete
17 Housing
18 Front cover
19 Mounting base
20 Top plate
21 Drip tray
22 Collar band

DAN DRYER 3192 Column Large Capacity Hand Sanitiser -
tuhbe

DAN DRYER A/S
Alsikevej 8
DK – 8920 Randers NV
Tel: +45 8641 5711
Email: info@dandryer.dk
dandryer.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals