USER MANUAL
COLUMN JUNIOR
MODEL: 3492/3493/3494 (ADAPTER)
MODEL: 3496/3497/3498 (BATTERY)
3492 Column Junior
IMPORTANT!
This product falls within the scope of the WEEE directive on recycling and
recovery of waste electrical and electronic equipment.
- This product should not be disposed of with general household waste
- This product must be reused if possible
- Contact your local authority for further details
- This product may also be returned to the manufacturer/retailer for proper treatment, recovery, and recycling
DIMENSIONS AND TECHNICAL SPECIFICATIONS
Dimensions
Unit of measurement: mm
TECHNICAL SPECIFICATIONS
DESCRIPTION | DATA |
---|---|
Material | Steel |
Voltage (adapter version) | 6V DC, 230VAC/6VDC adapter included |
Voltage (battery version) | 6V DC, battery box (included) for 4x D-type LR20 |
batteries (not included)
Sensor type| Infrared, self-adjusting
Sensor range| Preset at 100 mm
Dosage amount| 1-1.2 ml (4100-5000 activations / 5 litre bottle)
Pump life| 100,000 activations
Mechanism life| 500,000 activations
Bottle| 5 l
Net weight| 11.55 kg
Gross weight| 13.50 kg
PRODUCT TYPE / MODEL
Adapter | Battery |
---|---|
3492 Sanitiser stand, white | 3496 Sanitiser stand, white |
3493 Sanitiser stand, black | 3497 Sanitiser stand, black |
3494 Sanitiser stand, RAL Classic | 3498 Sanitiser stand, RAL Classic |
GENERAL SAFETY INFORMATION
WARNING
- Turn off the power to the unit before servicing or cleaning
- Never make alterations to the product
- Never insert objects into any opening in the product
- The product is not intended for playing purposes
- Cleaning and maintenance only by qualified persons
- The product may only be used for the applications described in this manual
- Do not use any accessories not recommended by the manufacturer
- The product should be checked on a regular basis. Never use a defective or malfunctioning unit
- Never make alterations to the product affecting its performance. DAN DRYER’s product warranty does not cover product problems that result from misuse or alteration
NOTE
If the power cord is damaged, it must be replaced immediately. Disconnect the
electricity supply cord according to instructions.
This product is not intended for use by persons (inclusive children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are
supervised or have been given instructions concerning use of the product by a
person responsible for their safety.
Children should be supervised to ensure this product is used correctly.
INSTALLATION
Make sure the main breaker is turned off. Installation must be carried out by a qualified person in accordance with applicable standards in the country concerned.
1) Use the special key supplied to open the door.| dandan DRYER DRYER
2) Pull wire, plastic tube, and faucet coupling through the hole in the top
plate.
---|---
|
3) Pull the tube and wire through the rubber gasket, nylon bushing, and
clamping nut.| 4) Place the faucet in the center before tightening the nut. Do
not use any tools.
|
5) Attach the transparent plastic hose to the pump nozzle piece.| 6) Pay
attention to the power plug orientation pin.
|
7) Connect the plugs on the wires between the faucet and the control box.| 8)
Insert the drip tray in the support rails, lengthwise, under the top plate.
|
ADAPTER (MODEL 3492-3494)
9,1A) Connection with an adapter. Push the cable through the cable lead-in at
the bottom of COLUMN.| ADAPTER (MODEL 3492-3494)
9,2A) Push cable further upward and through the ’rack’.
|
BATTERY (MODEL 3496-3498)
9,1B) Connect to the external battery box. Install the battery box on the
backplate bracket in the lower storage space. Tighten using the butterfly
nut.| BATTERY (MODEL 3496-3498)
9,2B) Push the cable through the rack via the cable lead-in.
|
10) Power connection to the box. Connect the plug to
the control box.| 11) Take off 5 liter bottle screw lid. We
recommend you drill a Ø7 hole for the hose. Or remove the lid completely.
|
12) Place the 5-liter bottle on the rack. Insert the tube through the hole in
the lid and into the bottle.| 13) Close the front cover and the unit is ready
for use.
|
REPLACEMENT OF BATTERIES AND PUMP
- Open the battery pack with a screwdriver PH2.| 15) Replace (4) D-batteries
in the battery pack.
---|---
| - Replacement of pump unit. Remove the tube from the pump unit.| 17) Detach
clip from hooks as shown.
| - Remove the existing pump unit.| 19) Insert new pump. Make sure the pump
guideways fit those of the control box. See illustrations.
| - Attach the clip on the hooks as shown.| 21) Attach tube to the new pump
unit.
|
PRODUCT APPLICATION
- Place hands approx 2-10 cm under the sensor to activate the dispenser. The dispenser will release 1-1.2 ml. disinfectant gel
- Move hands away after disinfectant release
- Stops automatically when hands are moved away
IMPORTANT!
- Ensure easy access to cleaning and maintenance of the product
- Do not bend the plastic tube too sharply. It will cause reduced dosage or total block total blockage in the
- Ensure the unit is placed on a firm and stable base
LIGHT INDICATOR (ADAPTER)
Standby | Red light |
---|---|
Active | Greenlight |
Obstruction of sensor | Flashing green and red light |
LIGHT INDICATOR (BATTERIES)
Standby | No light |
---|---|
Active | Greenlight |
Obstruction of sensor | Flashing green and red light |
CLEANING AND MAINTENANCE
Routine cleaning and maintenance is recommended
REPLACEMENT OF DISINFECTANT BOTTLE
- Use the key supplied to open the door
- Remove the empty bottle from the rack
- Replace with the new bottle
- Insert the pump tube into the bottle
- Close the door
CLEANING AND MAINTENANCE OF THE CONTROL BOX
- Cut the power
- Remove any dust and dirt
- Do not rinse with running water
- Use a damp cloth and mild cleaning solution. Never use cleaning detergents with an abrasive effect
CLEANING AND MAINTENANCE OF TAP/SENSOR
- Do not rinse with running water
- Use a damp cloth and mild cleaning solution. Never use cleaning detergents with an abrasive effect
- Clean sensor for dust and dirt to prevent unintentional activation
TROUBLESHOOTING AND CORRECTIVE ACTIONS
SYMPTOM | POTENTIAL CAUSE | CORRECTIVE ACTION |
---|---|---|
No disinfectant is delivered | Low supply | Refill the disinfectant bottle |
Sensor window is dirty | Clean the sensor window | |
Obstruction in front of the sensor window | Remove the obstruction | |
Damaged sensor | Contact DAN DRYER for advice | |
Tube disconnected from pump | If the end of the tube is damaged, please remove |
the damaged part. The undamaged tube is to be mounted on the nozzle exit of
the pump
Sensor cabling disconnected from the control box| Check that the cable from
the faucet is installed correctly in the control box
The power supply has been disconnected| Check that the cable from the adapter
or the external battery box is installed correctly in the control box (see
page 7)
AC/DC adapter not connected| Check that the AC/DC adapter is plugged into the
wall and is getting power
The dispenser activates unintentionally| The sensor window is dirty| Clean the
sensor window
Obstruction in front of the sensor window| Remove the obstruction
| Damaged sensor| Contact DAN DRYER for advice
PARTS LIST
No | Description |
---|---|
1 | Faucet complete |
2 | End piece |
3 | Rubber ring |
4 | Holder for LED print and sensor |
5 | Rubber gasket (top) |
6 | Rubber gasket (bottom) |
7 | Nylon bushing |
8 | Clamping nut |
9 | Tube/nozzle connecting part |
10 | Nozzle for disinfectant |
11 | Tube 700mm |
12 | Control box (DC) |
13 | Pump for disinfectant |
14 | AC/DC adapter |
15 | External battery box |
16 | Lock complete |
17 | Housing |
18 | Front cover |
19 | Mounting base |
20 | Top plate |
21 | Drip tray |
22 | Collar band |