Danfoss KE14001 Feeder Control Board User Guide
- May 15, 2024
- Danfoss
Table of Contents
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: 763-509-2084 Telefax:
763-559-0108
Unit Specification
KE14001
Feeder Control Board
ISSUE: 1 DATE: February 1994
GENERAL DESCRIPTION
The KE14001 Feeder Controller accepts the signal from an MCX130A1002
Ultrasonic Sensor or an ACX104C1167 Potentiometer Sensor and actuates an
Electrical Displacement Control (EDC) on a hydrostatic pump for the auger on
an asphalt paving machine. The KE14001 controls the height of the asphalt pile
ahead of the screed. When used with an ultrasonic sensor and an external
setpoint potentiometer, the distance between the sensor and the asphalt pile
can be controlled from approximately 9″ to 34″.
The controller is a 3″ wide by 4!s” long PWB assembly. It has two trim
potentiometers to adjust the offset and gain and three LEDs to indicate +12V
power, +8V regulator and output current. The +8V regulator terminal can be
used to power the ACX104C1167 Potentiometer Sensor and/or to power an external
setpoint potentiometer (such as the K00573 1-kilohm
potentiometer) when the MCX130A1002 Ultrasonic Sensor is used. An external
switch can be connected to change the gain from high to low. It has a
10-position terminal strip for external connections.
DIMENSIONS
Dimensions of the KE14001 in millimeters (inches).
CONNECTION DIAGRAM
TECHNICAL DATA
RATED VOLTAGE 12 Vdc
OUTPUT CURRENT 150 mA
OUTPUT CHARACTERISTICS
.© Danfoss, 2013-09
K15696 UNIT SPEC
Read User Manual Online (PDF format)