Specifications

  • Adjustment range (range configurable via advanced settings)
  • Maximum load current (for category AC-1): 16 A
  • Rated load capacity (for category AC-1): 3,000 V
  • Input voltage: 230V ~ 50 Hz
  • Weight in the complete set: 0.1 m
  • Temperature sensor: Included
  • The length of the sensor-connected cable: 1 meter
  • Number combinations under heat, at least: 50,000 cycles
  • Number of combinations without heating, no less than 20,000,000 cycles
  • Temperature hysteresis: Not specified
  • Degree of protection GOST14254: IP20

Product Usage Instructions

Connection

  1. The fork of Terneo rz plugs into a standard wall socket 230V ~ 50 Hz with grounding.
  2. The socket must be designed for a current of at least 16 A.
  3. Connect the thermostat in the socket and then connect the load to the thermostat socket. Ensure the thermostat commutes the current not more than 2/3 of the maximum power specified.

Installation Steps

  1. Switch on the thermostat.
  2. Adjust the preset temperature using the menu.
  3. Block/unblock buttons as needed.
  4. Reset to factory settings if required.
  5. View the firmware version.

External Temperature Sensor Resistance The resistance of the external temperature sensor at different ambient temperatures:

  • 25°C: 25339 Ohms
  • 0°C: 19872 Ohms
  • -10°C: 12488 Ohms
  • -20°C: 8059 Ohms
  • -30°C: 5330 Ohms

FAQ

  • Q: What is the warranty period for internet devices?
    • A: The warranty for terneo devices is valid for 36 months from the date of sale, provided that the instructions are followed. For products without a warranty certificate, the warranty period is counted from the date of production.
  • Q: How does the thermostat control heating?
    • A: According to the data from the temperature sensor, the thermostat turns off the heating when the desired temperature is reached and turns it on when it drops by the hysteresis value.
  • Q: What does the flashing dot indicate during relay activation?
    • A: If there was less than 1 minute between relay switching, the relay activation will be delayed, marking the countdown with a flashing dot to protect against frequent switching in the thermostat.
  • Q: How are settings saved in case of a power outage?
    • A: The non-volatile thermostat storage saves all settings in the event of a power outage.
  • Q: What is the recommended ambient temperature range for optimal performance?
    • A: The thermostat is designed to operate within a standard room temperature range of X°C to Y°C for optimal performance.

Terneo srz thermostat is designed to maintain constant temperature within the range from 0 to 30 °C using heating or cooling equipment. According to the data from the temperature sensor, the thermostat turns off the heating when the desired temperature is reached and turns it on when it drops by the hysteresis value

IN THE BOX

  • Thermostat:  1 piece
  • Technical data sheet and installation and operation manual and warranty card:  1 piece
  • The packing box:  1 piece

TECHNICAL DATA

terneo-srz-Smart-Control-of-Heating-fig
\(1\)

IMPORTANT. Before the installation and operation of the device, please read by the end of this document. This will help to avoid possible danger, mistakes and misunderstandings

  • RELIABILITY OF THE POWER RELAY provides protection against frequent switching in the thermostat. If there was less than 1 minute between relay switching, the relay activation will be delayed, marking the countdown with a flashing dot
  • NON-VOLATILE THERMOSTAT STORAGE saves all settings in the event of a power outage
  • THE TOUCH CONTROL OF THE DEVICE IS SENSITIVE to strong electromagnetic fields and interferences (for example, fluorescent lamps, induction furnaces, etc.), close proximity to which may cause false operation of the touch buttons or their blocking. Please take this fact into account when installing.
  • DURABILITY AND RELIABILITY OF POWER RELAY CONTACTS is ensured by turning on the load as close as possible to the moment when the voltage sinusoid cross zero point. Small deviations from the zero crossing are possible due to different trip times of different types of power relay.

CONNECTION

The fork of terneo rz plugs into a standard wall socket 230 V ~ 50 Hz with grounding. The socket must designed for a current of at least 16 A. The design of the socket should provide a reliable contact.

In order to connect the thermostat:

  • connect the thermostat in the socket;
  • connect the load to the thermostat socket.

It is necessary that the thermostat commutes the current not more than 2/3 of the maximum power specified in the passportterneo-srz-Smart-Control-of-
Heating-fig \(2\)

INSTALLATION

The thermostat is designed for indoor installation. The ingress risk of moisture or liquid into the place of installation must be minimized To protect against short-circuits in the load circuit the circuit breaker (CB) has to be installed before installing the thermostate . The circuit breaker is installed in the gap of phase conductor. It should be designed for not more than 16 A. It is prohibited the use of a thermostat inside the greenhouse to prevent oxidation of outlet contacts, which can lead to damage to the device To protect person from electric shock leak is set SSD (safety shutdown device). The cross section of the wires connected to device should
correspond to the amount of electric current consumed by the load.

EXPLOITATION

Use the button to select the desired menu item. Use or to change the parameters. The first press causes a flashing of the parameter, the next one a change. Temperature display returns after seconds after the last pressing the buttons. Temperature display returns after seconds after the last pressing the buttons.

Switching on the thermostat

  • * To enable/disable, hold for 4 sec. 3 dashes will appear on the screen one by one,
    • then or . « » «on» «oFF

Preset temperature

(factory setting 23 °С)  Preset temperature Use and to select the temperature.If sensor fails, the thermostat will continue to operate in emergency timer mode

Button blocking

  • In order to enable disable button blocking press the and buttons at the same time for 3 seconds till the (UNLOCK )  sign appears on the screen.

Resetting to factory settings

  • To reset, hold down three buttons and hold for more than 6 seconds DEF. inscription will appear on the screen. After releasing the buttons, the screen blinks off and the thermostat restarts.

Firmware version view

Holding the button for more than 6 seconds will display the firmware version on the screen. After releasing the button, the thermostat returns to the normal operation mode. «≡» The manufacturer reserves the right to modify the firmware to enhance the device technical characteristics

RESISTANCE OF EXTERNAL TEMPERATURE SENSOR at different ambient temperatures

WARRANTY TERMS

The warranty for terneo devices is valid for  36 months from the date of sale, provided that the instructions are followed. The warranty period for products without a warranty certificate is counted from the date of production. If your device is not working properly, we recommend that you first read the section «Possible problems». If you cannot find an answer, contact the Service Center. In most cases, these actions resolve all issues. If you continue to have issues with the device, please send it to a Service Center or to the store where you purchased the device. If your device is defective due  to our fault, we will repair or replace it under warranty within 14 business days. Please see the full text of the warranty and the data you need to send to your Service Center on the website https://www.ds- electronics.company. If you have a warranty case, please, contact the General distributor in your area.

SERVICE CENTER CONTACT

terneo-srz-Smart-Control-of-Heating-fig \(11\)

Use or to change the parameters. The first press causes a flashing of the parameter, the next one — a change. Temperature display returns 5 seconds after the last pressing the buttons

МЕNU

terneo-srz-Smart-Control-of-Heating-fig
\(12\) terneo-srz-Smart-Control-of-Heating-fig
\(14\)

ADDITIONAL INFORMATION

Do not fire and do not throw away the device with the household waste. After the end of its service life, the product must be disposed of in accordance with applicable law. Transportation of goods carried in the package, ensuring the safety of the product. The devi e is transported by any kind of transport (rail, sea, motor, air transportation) Date of manufacture is on the back side of device. Application time is unlimited. The device does not contain harmful substances If you have any questions or you something will not clear, call the Service centre the telephone number listed below

POSSIBLE PROBLEMS, CAUSES AND WAYS TO OVERCOME THEM

While the load is running, the symbol « t »  flashes on the screen

Possible cause: damage to the sensor and its circuit It is necessary: to check the integrity of the sensor and the absence of mechanical damage to its circuit, the absence of power wires that are laid close. Timer-based emergency operation mode (factory setting
This mode ensures the operation of the thermostat in case of damage to the sensor: in a 30-minute cyclic interval it turns on the load for the set time, the rest of the time the load is turned off. The load operating time  is adjustable from 1 to 29 minutes using the orbuttons. To ensure continuous operation of the load, select and to turn the load completely off, select . Heating temperature control is not available

Load is off, screen and indicator are off

Possible cause: No power supply. It is necessary: make sure that the supply voltage is available. If power supply is available, contact the Service Center.

The load does not work, the screen flashes «oht»

  • The temperature inside the housing exceeded 80 °C, the protection against internal overheating worked.

Possible cause: internal overheating of the thermostat. It can occur if the socket that powers the device or the plug of the load is not designed for the required power, the ambient temperature is high, or the power of the switched load is exceeded. It is necessary: to make sure that the socket powering the device or the load plug is designed for the required power and the load power does not exceed the allowable one. Features of the protection against internal overheating: when the temperature inside the housing drops below 60 °C, the thermostat will resume operation. When the protection is triggered more than 5 times in a row, the thermostat will be blocked until the temperature inside the housing drops below 60 °C and one of the buttons is pressed.

Every 4 seconds the screen displays «Ert»

  • Possible cause: is a break or short circuit of the internal overheating sensor. Internal overheating is not monitored

It is necessary: to send the thermostat to the service center. Otherwise, overheating control will not be carried out.

When you turn on the screen for 5 seconds «Er0» is displayed

  • Possible cause: malfunction of the control system for the transition of the sinusoid through zero

It is necessary: send the thermostat to the service centers. Otherwise, the control over crossing of the sinusoid through zero will not be carried out.

SAFETY INSTRUCTIONS

Carefully read and become aware of these instructions. Before the installation (dismantling) and connection (disconnection) of the device, turn off voltage supply and also act according to the «Rules of an arrangement of electric installations». Do not immerse the sensor with a connecting wire in the liquid medium. Do not switch the non-assembled device to the network. Avoid hitting of water or moisture to the device. Do not expose the device to extreme temperatures (higher than 40 ºС or below –5 °C) and high humidity. Never clean the device with the use of chemicals such as benzene, or solvents. Do not store the device and do not use it in areas with the dust. Do not attempt to disassemble and repair the device. Do not exceed the landmarks value adaptor and power. To protect against overvoltage caused by lightning discharges, use a lightning protector. Protect the children from games with the working device, it is dangerous.

Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU

Manufacturer and vendor: DS ELECTRONICS, LTD

04136, Ukraine, Kyiv region, Kyiv, 1–3 Pivnichno-Syretska str

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals