Next Century RR4-TR Remote Reader User Manual
- June 6, 2024
- Next Century
Table of Contents
RR4-TR Remote Reader
User Manual
Welcome to your new Remote Reader with integrated NextCentury Transceiver (Radio). The RR4-TR is an advanced meter reading solution that provides a high visibility remote display of one or two u-lity meters. It includes wireless AMR support with the NextCentury Cloud Pla[orm. Se\ng up and installing the Remote Reader is quick and easy.
Packaging Contents
A) RR4-TR Remote Reader | E) Box Mount Screws #6-32 |
---|---|
B) Moun-ng Plate | F) Wire Security Assembly |
C) Sheetrock Anchors | G) Ac-va-on Magnet (one per case) |
D) Wall Mount Screws #6-20
Important
During install-on, you will disconnect the Remote Reader fromthe Moun-ng Plate. It is not necessary to open the Remote Reader. The Remote Reader is a sealed, watertight design, and should only be opened to replace the battery (10-year approximate bakery life).
Addi$onal Resources
products.nextcenturymeters.com/rr4-tr
For a full installation guide, spec sheets, and addi-on resources, please visit: products.nextcenturymeters.com/rr4-tr
Contact Information
Phone: 844.538.8203
Email: support@nextcenturymeters.com
Installation
Pull Down Security Tab to Remove Remote
A reader from Mounting Plate| Secure the Mounting Plate and
Connect Meter(s)| Connect Remote Reader to Mounting Plate Then
Lock Security Tab
Installation Steps
- Disconnect the Remote Reader from the Mounting Plate. Remember to first pull down on the Mounting Plate Security Tab.
- Install the Mounting Plate using the anchors and #6-20 screws, or use the #6-32 screws to install on a single gang wall box.
- Connect the wire output from one or two meters to the Remote Reader Mounting Plate (wiring instructions on the other side of this guide).
- The Remote Reader ships with a default configuration to read one pulse-type water meter. To program, the Remote Reader for other configurations see the “Programming” section on the last page.
- Test the meter connection: – For pulse meters, ensure the pulse-count increments when a pulse is sent from the connected meter. – For encoder meters, ensure the proper read is displayed. It may be necessary to tap the display or swipe a magnet to get the latest encoder meter read.
- Test the Integrated Transceiver’s network connection using a magnet to initiate a check-in. If the Remote Reader is programmed and able to communicate with the Gateway, the LED will blink green twice.
Configuration Options:
• 1x Pulse Meter – Default (Meter 1 Port)| • 1x Encoder & 1x Pulse (Meter 1 &
2 Ports)
---|---
• 1x Encoder Meter (Meter 1 Port)| • 1x Pulse & 1x Encoder (Meter 1 & 2 Ports)
• 2x Pulse Meters (Meter 1 & 2 Ports)| • 1x Pulse with Pulse Out (Meter 1 & 2
Ports)
• 2x Encoder Meters (Meter 1 & 2 Ports)|
Wiring Guide
An interac5ve Wiring Guide is also available through the NextCentury Mobile App (Android and iOS Support).
Dual Meter+™
Meter+™ Technology has been developed to allow a single device to connect to virtually all modern meter outputs. These include a variety of different pulse- out meters as well as encoded output meters. Meter+™ Technology supports Neptune, Sensus, GWF, and Elster/AMCO 3-wire protocols. Simply wire the meter and program the Remote Reader with the applicable configura5on. The Remote Reader includes two Meter+™ Technology ports, allowing for a large variety of configurations.
The Serial Number is located on the face of the Remote Reader. This identification number always ends with a “0.” When communica5ng with the next century Web PlaXorm through a Cellular Gateway (GW4), each meter is assigned a unique Transceiver Serial Number. The Serial Number for Meter 1 will end with a “1” and the serial number for Meter 2 will end with a “2.”
Direct Connect
Note: the DC301 wireless programmer is not required for configuring this model.
Programming
Option 1: The NCSS Mobile App is used for simple in-field programming and
configuraKon. The Mobile App allows your device to communicate directly with
the
Remote Reader to program and verify your installation.
Option 2: If a NextCentury Cellular Gateway (GW4) and an internet connection
are available while programming the Remote Reader, setup and configuraKon can
be completed using the Online Web Portal or Mobile App.
Mobile App Download
http://products.nextcenturymeters.com/mobile?platform=ios&device=rr301-tr| http://products.nextcenturymeters.com/mobile?platform=android&device=rr301-tr
Additional Products
- GW4: Cellular Gateway
- RE4: Wireless Network Repeater
- Pre-Programming: Equipment pre-configured and ready for install
For more, visit: www.nextcenturymeters.com or contact sales@nextcenturymeters.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>