Termed VT thermostat is designed to maintain constant temperature from 0 to 35
° in electric heating systems.
According to data from the internal temperature sensor, the thermostat turns
off the heating when the desired temperature is reached and turns on when it
decreases by 1 °C.
IN THE BOX
Thermostat, frame | 1 piece |
---|---|
Technical data sheet and installation and operation manual and warranty card |
1 piece
The packing box| 1 piece
TECHNICAL DATA
Adjustment range | 0…35 °С |
---|---|
Maximum load current (for category AC-1) | 16 А |
Rated load capacity (for category AC-1) | 3 000 VА |
Input voltage | 230 V ±10 % |
Weight in the complete set | 0,18 kg ±10 % |
Overall dimensions (w × h × d) | 75 × 75 × 39 mm |
Temperature sensor | NTC thermo-resistor 10 kOhm 25 °C (R10) |
Number combinations under heat, at least | 50 000 cycles |
Number of combinations without heating, no less than | 20 000 000 cycles |
Temperature hysteresis | 1 °С |
Degree of protection GOST14254 | IP20 |
IMPORTANT. Before the installation and operation of the device, please
read by the end of this document. This will help to avoid possible danger,
mistakes and misunderstandings.
RELIABILITY OF THE POWER RELAY provides protection against frequent switching
in the thermostat. If there was less than 1 minute between relay switching,
the relay activation will be delayed, marking the countdown with a flashing
dot.
NON-VOLATILE THERMOSTAT STORAGE saves all settings in the event of a power
outage.
WIRING
Power voltage (230 V ± 10 %, 50 Hz) is supplied to terminals 4 (neutral, N)
and 5 (phase, L) .
Load (connecting wires from heating element) is connected to terminals 3 and
6.
THE THERMO STAT IS MOUNTED AND CONNECTED after the installation and load
testing
INSTALLATION
The thermostat is designed for indoor installation.
The ingress risk of moisture or liquid into the place of installation must be
minimized. When installed in a bathroom, toilet, kitchen, swimming pool the
thermostat should be installed at the place out of reach of casual spraying.
The ambient temperature during installation must be between –5 … + 45 °C. The
installation height of the thermo should be in the range 0,4 1,7 m above …
the floor level.
To protect against short-circuit in the load circuit the circuit breaker (CB)
has to be installed before installing the thermostat 1. The circuit breaker
is installed in the gap of phase conductor, as shown in the Wiring . It should
be designed for not more than 16 A.
For installation you must:
- make a hole in the wall for box mounting and wall chase for power wires and the sensor
- take the power wires of the heating system to the mounting box
- perform the compounds according to the passport data;
- fix the thermos stat in the mounting box.
The thermostat terminals are designed for a wire with section not more than
2,5 mm . To reduce the mechanical loads on the terminals it is desirable to
use a soft wire. 2 The wires are tightened in the terminals using a
screwdriver with a blade width no more than 3 mm. , The terminals should be
tighten with torque 0 5 N m. Use of aluminum is not desirable The sections of
the wires, which is connected to the · . thermos stat, must be at least copper
2 × 1,0 mm . 2 The screwdriver with a blade width more than 3 mm can cause
mechanical damage to the terminals. This may result in the loss of right for
warranty.
It is important to remember that it is desirable to place the on the inner
wall of the room. It is recommended to store out the thermostat of direct
sunlight and drafts (Fig. 1). It is necessary for the thermostat to switch the
current to no more than 2/3 of the maximum current specified in the
specification. If the current exceeds this value, the load must be connected
through a contactor (magnetic actuator, power relay), which is optimized for
this current (Wiring 2).
|
---|---
SET THE LOAD POWER TO 100 W WHEN CONTROLLED VIA CONTACTOR for correct measurement of air temperature by thermostat.
WARRANTY TERMS
The warranty for terneo devices is valid for 36 months from the date of sale,
provided that the instructions are followed. The warranty period for products
without a warranty certificate is counted from the date of production.
If your device is not working properly, we recommend that you first read the
section «Possible problems». If you cannot find an answer, contact Service
Center.
In most cases, these actions resolve all issues.
If you continue to have issues with the device, please send it to a Service
Center or to the store where you purchased the device. If your device is
defective due to our fault, we will repair or replace it under warranty within
14 business days.
Please see the full text of the warranty and the data you need to send to your
Service Center on the website https://www.ds-
electronics.com.ua/en/. If you have a
warranty case, please, contact the General distributor in your area.
SERVICE CENTER CONTACT:
+38 (091) 481-91-81
WhatsApp Viber Telegram
support@dse.com.ua
WARRANTY CARD
serial №:……………………………..
date of sale:…………………………
a seller, a seal:………………………
place of a seal an owner contact for a service center:…………..
SET THE POWER OF THE CONNECTED LOAD before its operation.
EXPLOITATION
Hold down «–»button for a certain number of seconds (see Table 1). Then change
the parameter with the«+» and «–»buttons. 3 seconds after the last pressing,
the thermostat will automatically return to the sensor temperature display. In
the waiting mode (when the buttons aren`t currently being used) the brightness
of the indicator and the screen will be reduced to 30 %.
Preset temperature ( factory setting 25 °С)
When button«–» or«+» is pressed thermoregulatory switches to the mode of
display and change of preset temperature. While flashing, if button «+» is
pressed tpreset will be increased, if button «–» is pressed preset will be
decreased.
Switching to sleep mode
Hold down the « » + button for 4 seconds « »oFF (three dashes will appear
on the screen one after the other) until appears on the screen. To turn it off
completely, you need to turn off the automatic switch.
To exit sleep mode, also hold the « » « »on + button for 4 seconds until
appears on the screen.
Button blocking (child and public protection)
In order to enable /disable button blocking press the «+» and «–»
buttons at the same time for 6 seconds till the «Loc» ( «oFF» ) sign
appears on the screen
POSSIBLE PROBLEMS, CAUSES AND WAYS TO OVERCOME THEM
Heating temperature does not correspond to the settings
Possible cause: load power is not correctly set.
It is necessary: to correctly set the load power (Tab. 1).
If it is installed correctly, contact the Service Center.
Load is off, screen and indicator are off
Possible cause: No power supply.
It is necessary: make sure that the supply voltage is available. If power
supply is available, contact the Service Center.
The load does not work, theПРГ « » flashes on the screen
The temperature inside the housing exceeded 8 °C, the protection against
internal overheating worked.
Possible cause: internal overheating of the thermostat, which can be caused
by: poor contact in the terminals of the thermostat, high ambient temperature,
exceeding the power of the switching load, or the cross section of the wires
for connection is incorrectly selected.
It is necessary: to check the tightening of power wires in the terminals of
the thermostat, make sure that the switching load power does not exceed the
permissible one, the cross section of the wires for connection are selected
correctly.
Features of the protection against internal overheating: when the temperature
inside the housing drops below 8 0 °C, the thermostat will resume operation.
When the protection is triggered more than 5 times in a row, the thermostat
will be blocked until the temperature inside the housing drops below 0 °C and
one of the buttons is rested.
Every 5 seconds the screen displays Ert« »
Possible cause: is a break or short circuit of the internal overheating
sensor. Internal overheating is not monitored.
It is necessary: to send the thermostat to the service center. Otherwise,
overheating control will not be carried out.
ADDITIONAL INFORMATION
Do not fire and do not throw away the device with the household waste.
After the end of its service life, the product must be disposed of in
accordance with applicable law.
Transportation of goods carried in the package, ensuring the safety of the
product.
The devi e is transported by any kind of transport (rail, gearmotor, air
transportation).
Date of manufacture is on the back side of device.
Application time is unlimited.
The device does not contain harmful substances.
If you have any questions or you something will not clear, call the Service
centre the telephone number listed below.
SAFETY INSTRUCTIONS
Carefully read and become aware of yourself these instructions.
Connection of the device must be done by a qualified electrician.
Do not connect 230 V mains voltage instead of the sensor (it leads to failure
of the thermostat).
Before the installation (dismantling) and connection (disconnection) of the
device, turn off voltage supply and also act according to the «Rules of an
arrangement of electric installations».
Do not immerse the sensor with a connecting wire in the liquid medium.
Do not switch the non assembled device to the network.
Turning on and off or and configure the device should be with dry hands.
Do not connect the device to the network disassembled.
Avoid hitting of water or moisture to the device.
Do not expose the device to extreme temperatures (higher than 40 ºС or below
–5 °C) and high humidity.
Never clean the device with the use of chemicals such as benzene, solvents.
Do not store the device and do not use it in areas with the dust.
Do not attempt to disassemble and repair the device.
Do not exceed the landmarks value adaptor and power.
To protect against overvoltage caused by lightning discharges, use a lightning
protector.
Protect the children from games with the working device, it is dangerous.
Table 1. FUNCTION MENU
Menu section| Hold «≡»| Screen| Notes
Correction of screen reading (factory setting 0, range ±5,0 °С, step 0,1
°С)| 6 sec| | If necessary you can use the adjustment in the floor temperature
display on the thermostat screen.
Load power setting (factory setting 1,2 kW, range 0,1 – 3,0 kW, step 0,1
kW)| 9 sec| | Be sure to set the load power. The accuracy of measurements
depends on it.
Firmware version| 11 sec| | The manufacturer reserves the right to
modify the firmware to enhance the device technical characteristics.
Resetting to factory settings| 30 sec| | After releasing the button, the
thermoregulatory will reset all settings to the factory settings and will
reboot.
Low Voltage Directive 2014/35/E U
EMC Directive 20 4/1 30 U/E
Manufacturer and vendor: DS ELECTRONICS, LTD
04136, Ukraine, Kyiv region, Kyiv, 1-3 Pivnichno-Syretska str.
+38 (091) 481-91-81, Service Center: +38 (091) 481-91-81
support@dse.com.ua
www.ds-electronics.com.ua/en/
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>