Product Introduction

Thank you for choosing POVERVIN. Our solar charge controller is compatible, light weight, and functional. It is designed to maximize the solar charging speed, instead of adjusting low/high voltage into a specific value of constant voltage.

Get to Know Your Product

  1. FrontPOWERWIN MT01 50A Solar Charge Controller 
  2. BottomPOWERWIN MT01 50A Solar Charge Controller - Botton

Interface Display & Settings

  1. Specs at a Glance
    Click the button to switch the display of specs.POWERWIN MT01 50A Solar
Charge Controller - Glance1) Charging Cutoff (HVD) mode automatically suspends solar charging when the preset battery voltage is reached. This mode is crucial in preventing battery damage caused by overcharging.
  1. Recovery (LVR) mode enables the product to resume the output connection when the battery voltage returns to the preset level after being cut off from charge or discharge.
  2. Discharge Cutoff (LVD) mode automatically shuts down the load when the battery voltage reaches a preset minimum level, thus safeguarding the battery against overload and potential damage.
  1. How to Modify
    1. Hold the button until the number blinks.
    2. Click Up or
    [Downl button to modify specs.
    3. Hold , the (Menu) button once again to quit. The system will automatically remember the set value.
    4. Hold the button for 10 seconds to reset.

Set Up Your Battery Type

ATTENTION

  1. When installing the battery, please ensure sufficient voltage for the controller to recognize the correct battery type.
  2. When connecting the battery, keep the connection line < 4 ft to avoid voltage reduction caused by excessive wire length, which may affect the product’s ability to detect the battery voltage correctly.
  3. Avoid reversing the polarity when making the connection!

Lead Acid Battery (LA, 12 / 24V)
The product will automatically identify the battery as 12 / 24V LA battery upon connection. The default battery mode is (b1) for LA battery. After that, you’re all set.
Lithium Ion Battery (Li-ion, 3S 11.1V)

POWERWIN MT01 50A Solar Charge Controller - Ion
battery

  1. Click , the   button, and switch to Battery Model
  2. Hold le, the button until the number blinks.
  3. Click Up or WW [Down] button, and modify to [b2l for Li-ion battery.

LiFePO Battery (LFP, 4$ 12.8V)

POWERWIN MT01 50A Solar Charge Controller - Ion battery
1

  1. Click , the   button, and switch to Battery Model
  2. Hold le, the button until the number blinks.
  3. Click Up or WW [Down] button, and modify to [b2l for Li-ion battery.

Recommend Settings For Lithium Battery

ATTENTION
Please read the following the instruction carefully before connecting with Lithium battery. Improper connections or Settings may cause damage to the product or your battery!
How to Modify

  1. Hold the button until the number blinks.

  2. Click Up or [Downl button to modify specs.

  3. Hold the button once again to quick. The system will automatically remember the set value.

  4. Modifying Charging Cutoff VoltagePOWERWIN MT01 50A Solar Charge Controller - Ion battery 2

  5. Modifying Discharge Recovery Voltage­POWERWIN MT01 50A Solar Charge Controller - Ion battery 3

  6. Modifying Discharge Cutoff VoltagePOWERWIN MT01 50A Solar Charge Controller - Ion battery 4

Load-time Control Mode

Function Introduction
This function allows for presetting the number of hours the product’s output time limit. There is a total of 4 modes of time control. *Solar charging required.

  1. 24 h (Constant, Default)
    In this constant light mode, it needs to be adjusted manually to switch turning on/off the output.

POWERWIN MT01 50A Solar Charge Controller - Ion battery
5

How to Modify

  1. Hold the button until the number blinks.
  2. Click Up or [Downl button to modify specs.
  3. Hold the button once again to quick. The system will automatically remember the set value.

2. 0 h
The output function will start immediately after of no input charging.

3. 3 h
The output function will start after 3 hours of no input charging.

4. 8 h
The output function will start after 8 hours of no input charging.

Product Specifications

Battery Voltage 12V 24V Lead Acid
Nominal Input Current 50A
Nominal Output Current 30A
Solar Input Voltage Range 15-23V 30-46V
Max Solar Input Power 650W 1300W
Equalizing Charge Voltage 14.4V 28.8V
Continuous Charging Voltage 13.7V (Default) 27.4V (Default)
Discharge Cutoff Voltage 10.7V (Default) 21.4V (Default)
Discharge Recovery Voltage 12.6V (Default) 25.2V (Default)
Recharge Starting Voltage 13V (Defa ult) 26V (Default)
Rated Solar Voltage in Load-time Control Mode 8V 16V
USB Output 2 x 5V/2.5A
Standby current <10mA
Working Temperature -35-60°C / -31-140°F

Additional Note

  1. The product can only use solar panels as charging source, do not use other power sources as solar input.
  2. The product can only be charged with solar panels and cannot use other power sources. Additionally, the product generates heat during use, therefore, it should be installed in a flat and well-ventilated environment.

Warranty & Customer Services

Our company provides a 12-month warranty upon purchase. Any questions, please feel free to contact us at [email protected]

For more info, please visit:
POWERWINPOWER.COM

Documents / Resources

| POWERWIN MT01-50A Solar Charge Controller [pdf] Instruction Manual
MT01-50A, MT01-50A Solar Charge Controller, Solar Charge Controller, Charge Controller, Controller
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

POWERWIN User Manuals

Related Manuals