RAB CRLEDFA-xR-xxS-9CCT-UNV-WS Field Adjustable Commercial Downlight Instructions

June 17, 2024
RAB

RAB CRLEDFA-xR-xxS-9CCT-UNV-WS Field Adjustable Commercial Downlight

Product Information

Specifications

  • Model: CRLEDFA-xR-xxS-9CCT-UNV-WS
  • Field Adjustable Commercial Downlight
  • LED Lamp Operation
  • Optional Accessories Available

Product Usage Instructions

Installation

  1. Read all instructions carefully before installing the fixture.
  2. Ensure installation is done in accordance with applicable installation codes by a knowledgeable person.
  3. Use the provided tools for installation.
  4. Follow the steps for installation with an existing frame as outlined below.

Installation Steps with Existing Frame

  1. Remove CFL, Incandescent or HID lamp.
  2. Remove reflector from rough-in (mounting frame).
  3. Remove J-Box metal plate with existing lamp ballast. Do not dispose. Disconnect all wires from the ballast.
  4. Remove the existing lamp metal conduit (MC) cable from the J-Box.
  5. Select desired lumen and CCT level using switch on driver box.
  6. Wire nut the ground (green) wire in the junction box and follow wiring instructions for other wires as per color coding.
  7. Install the junction box cover plate.
  8. Turn power ON after installation is complete.

FAQ

Q: Can I use incandescent lamps with this luminaire?

A: No, this luminaire is modified to operate LED lamps only. Do not attempt to install or operate incandescent lamps in this fixture.

Q: Where can I find optional accessories for this downlight?

A: Optional accessories like Goof Rings, Frames, and Plates can be found on rablighting.com. Refer to the downlight accessory compatibility lists for more details.

Q: What should I do if the purple and pink wires are not in use during installation?

A: Cap these wires with wire nuts as per the wiring instructions provided.

INSTRUCTIONS

4″ 6″ 8″ 10″ Field Adjustable Commercial Downlight

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

CRLEDFA-xR-xxS-9CCT-UNV-WS

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS

  • Risk of electrical shock. Disconnect power at fuse or circuit breaker before installing or servicing.

  • To prevent early lamp failure, lamp should only be installed in operating environments ranging between -30°C and 40°C (-22°F and 104°F).

  • No user serviceable parts inside. To avoid electrical shock do not disassemble product.

  • Risk of fire or electric shock, LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

  • Risk of fire or electric shock, Install this kit only in luminaires that have the construction features and minimum dimensions shown in these instructions and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation

  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.

  • The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined
    by authorities having jurisdiction. Product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local national regulations for electrical installations. This device is not intended for use with emergency exits.

  • Caution – risk of fire. Consult a qualified electrician to ensure correct branch circuit conductor.

  • Minimum 90ºC supply conductors.

  • Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

WHAT’S IN THE BOX

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-1

Shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including relamping.

TOOLS NEEDED

This LED Recessed Kit requires very few tools for installation. A screwdriver and a pair of wirecutters will help to install the downlight to a JBox or housing.

OPTIONAL ACCESSORIES

Goof Ring
Visit rablighting.com for the downlight accessory compatibility lists.

  • DL4-6GOOF/R/P/CRLEDFA
    For use with 6″ ceiling hole applications

  • DL6-8GOOF/R/P/CRLEDFA
    For use with 8″ ceiling hole applications

  • DL8-10GOOF/R/P/CRLEDFA
    For use with 10″ ceiling hole applications

  • DL8-12GOOF/R/P/CRLEDFA
    For use with 12″ ceiling hole applications

  • DL10-12GOOF/R/P/CRLEDFA
    For use with 12″ ceiling hole applications

Plate

DLPLATE/C3468R/NB
Mounting plate with nailer bar

Frame

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-4

INSTALLATION WITH EXISTING FRAME

  1. Shut power OFF to the fixture.

  2. Remove CFL, Incandescent or HID lamp. (Fig. 1)

  3. Remove reflector from rough-in (mounting frame). (Fig.2)

  4. Remove socket assembly from reflector. (Fig.3)
    RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-5

  5. Remove J-Box metal plate with existing lamp ballast. Do not dispose. Disconnect all wires from the ballast. (Fig.4)

  6. Remove the existing lamp metal conduit (MC) cable from the J-Box. (Fig.5)

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-6

  1. Select desired lumen and CCT level using switch on driver box. (Fig.6)
  2. Fasten the LED retrofit kit MC cable to the J-Box. (Fiq.7)
  3. Wire nut the ground (green) wire in the junction box. Wire nut the black input wire with the black wire from the MC cable and wire nut the white input wire with the white wire from the MC cable. Wire nut the purple input wire with the purple wire from the MC cable and wire nut the pink input wire with the pink wire from the MC cable. If the purple and pink wires are not in use, cap these with wire nuts. (Fig.8)

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-7

  1. Install the junction box cover plate. (Fig.9)

  2. Install the retrofit kit in the rough-in by lifting upward both retention tabs. Push the kit until it sits flush against the ceiling. (Fiq.10)

  3. Turn power ON.

INSTALLATION WITHOUT EXISTING FRAME

  1. Use the template included in the box to cut a hole in the ceiling. (Fig.11)
  2. Select desired lumen and CCT level using switch on driver box. (Fig.12)

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-9

  1. Shut power OFF to the fixture. Fasten the LED kit MC cable to a junction box with MC connector. Wire nut the ground (green) wire in the junction box. Wire nut the black input wire with the black wire from the MC cable and wire nut the white input wire with the white wire from the MC cable. Wire nut the purple input wire with the purple wire from the MC cable and wire nut the pink input wire with the pink wire from the MC cable. If the purple and pink wires are not In use, cap these with wire nuts. (Fig. 13)
  2. Install junction box cover plate. (Fig.14)

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-10

  1. Install the LED kit by lifting both retention tabs upward. (Fig.15)
  2. Push the kit until it sits flush against the ceiling. (Fig. 16)

INSTALLATION WITH EMERGENCY BATTERY BACKUP

Take the Emergency Battery Backup System and snap in the MC cable from the EMBB into the J-Box. Fasten the LED retrofit kit MC cable to the J-Box. In the J-box, use wire nuts to do the wire connections as illustrated in the diagram below. Make sure Emergency Driver is grounded. Please visit rablighting.com to view the emergency battery backup compatibility list.

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-12

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

MINIMUM LUMINAIRE DIMENSION

DIMENSIONAL DRAWINGS

CRLEDFA-4R-12S-9CCT-UNV-WS

RAB-CRLEDFA-xR-xxS-9CCT-UNV-WS-Field-Adjustable-Commercial-Downlight-
FIG-14

Easy Answers

  • rablighting.com
    Visit our website for product info

  • Tech Help Line
    Call our experts: 888 722-1000

  • e-mail
    Answered promptly – sales@rablighting.com

  • Free Lighting Layouts
    Answered online or by request

RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

© 2022 RAB LIGHTING Inc.
Cranbury, New Jersey 08512 USA
CRLEDFA-IN-0922

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals