MITSUBISHI ELECTRIC PUY-A30NHA7 Ceiling Cassette Air Conditioning System Owner’s Manual

June 17, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC PUY-A30NHA7 Ceiling Cassette Air Conditioning System

Specifications

Indoor Unit

  • Operating Temperature Range: 90 DB, 72 WB / 66 DB, 61 WB

  • Fan Motor Full Load Amperage: 5.4 A

  • Fan Motor Output Airflow Rate [Cooling / Heating]: 95.2 / 95.2
    CFM

  • Compressor Type: INVERTER-driven twin rotary

  • Compressor Model: SNB172FWHM1

  • Compressor Rated Load Amps: 7 A

  • Compressor Locked Rotor Amps: 11.0 A

  • Refrigerant: R410A

  • External Finish Color: White Munsell 6.4Y 8.9/0.4

  • Unit Dimensions: 33-1/16 x 33-1/16 x 11-3/4 inches [840 x 840 x 298 mm]

  • Unit Weight: 35.9 lbs [16 kg]

Outdoor Unit

  • Operating Temperature Range: 115 DB / -40 DB
  • Compressor Type: INVERTER-driven twin rotary
  • Compressor Model: SNB172FWHM1
  • Compressor Rated Load Amps: 7 A
  • Compressor Locked Rotor Amps: 11.0 A
  • Refrigerant: R410A
  • External Finish Color: Ivory Munsell 3Y 7.8/1.1
  • Unit Dimensions: 37-13/32 x 13 (+1-3/16) x 37-1/8 inches [950 x 330 (+30) x 943 mm]
  • Unit Weight: 151 lbs [68 kg]

Product Usage Instructions

Installation Instructions

1. Ensure proper location for both indoor and outdoor units.

2. Connect the indoor and outdoor units with the specified piping length and correct pipe sizes.

3. Install the accessories for both units as per the user manual.

Operation Instructions

1. Use the wired remote controller to operate the indoor unit.

2. Set desired temperature and fan speed for optimal comfort.

Maintenance Instructions

1. Regularly clean air filters to maintain efficiency.

2. Schedule professional servicing for thorough system
check-ups. Frequently Asked Questions

Q: Can I use a wireless remote controller with the indoor unit?

A: No, the indoor unit is only compatible with the wired remote controller PAC-SF40RM-E.

Q: What is the maximum height difference allowed for piping installation?

A: The maximum height difference allowed for piping installation is 100 feet (30 meters).

Q: What type of refrigerant does the product use?

A: The product uses R410A refrigerant.

INDOOR UNIT FEATURES

  • Space-efficient ductless installation
  • Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
  • Airflow settings for high and low ceiling applications
  • Individual vane settings for direct/indirect airflow control or variable airflow patterns
  • Knockouts for outside-air intake and branch-duct run
  • Filter indicator signal
  • Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
  • Built-in condensate lift mechanism
  • Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
  • Multiple control options available:
    • Kumo cloud® smart device app for remote access
    • Third-party interface options
    • Wired or wireless controllers

OUTDOOR UNIT FEATURES

  • Variable speed INVERTER-driven compressor
  • Pre-charged with refrigerant volume for piping length up to 70 ft
  • Low ambient cooling down to -40°F providing 100% capacity (with wind baffles)
  • 24-hour continuous operation (cooling mode)
  • High-pressure protection
  • Fast restart
  • Superior energy and operational efficiency
  • Seacoast protection*
    • External Outer Panel: Phosphate coating + Acrylic-Enamel coating
    • Fan Motor Support: Epoxy resin coating (at edge face)
    • Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
    • Blue Fin treatment is an anti-corrosion treatment that is applied to the Heat exchanger coil to protect it against airborne contaminants.
    • Heat exchanger coil and base panel rated for 2,000 hours in accordance with ASTM B117 testing
    • Seacoast protection standard from 2022 production

SPECIFICATIONS

SPECIFICATIONS: PLA-A30EA7 & PUY-A30NHA7

Cooling at 95°F1

| Maximum Capacity| BTU/H| 30,000
---|---|---|---
Rated Capacity| BTU/H| 30,000
Minimum Capacity| BTU/H| 9,000
Maximum Power Input| W| 2,540
Rated Power Input| W| 2,540
Moisture Removal| Pints/h| 5.4
Sensible Heat Factor| 0.80
Power Factor [208V / 230V]| %| 95.2 / 95.2

Efficiency

| SEER | SEER2| 22.8 | 23.4
EER1 | EER21| 11.8 | 11.8
ENERGY STAR® Certified| No

Electrical

| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Recommended Fuse/Breaker Size (Oudoor)| A| 25
Recommended Wire Size [Indoor – Outdoor]| AWG| 14
Power Supply| Indoor unit is powered by the outdoor unit

Indoor Unit

| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.59
Fan Motor Type| DC Motor
Airflow Rate at Cooling, Dry| CFM| 570–670–780–880
Airflow Rate at Cooling, Wet| CFM| 530–630–740–840
Airflow Rate at Heating, Dry| CFM| 570–670–780–880
Sound Pressure Level [Cooling]| dB[A]| 28–32–35–38
Sound Pressure Level [Heating]| dB[A]| 28–32–35–38
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [849]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 11-3/4 // 1-9/16 [840 //

950 x 840 // 950 x 298 // 40]

Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 16-9/16 // 4-12/16 [903 //

1,000 x 871 // 970 x 421 // 121]

Unit Weight| Lbs. [kg]| 56 // 11 [25 // 5]
Package Weight| Lbs. [kg]| 77 [35]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum / Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB

Outdoor Unit

| MCA| A| 19.0
MOCP| A| 26
Fan Motor Full Load Amperage| A| 0.4
Fan Motor Output| W| 86
Airflow Rate [Cooling / Heating]| CFM| 1940
Refrigerant Control| LEV
Defrost Method| Reverse Cycle
Coating on Heat Exchanger| Blue Fin Coating**
Sound Pressure Level, Cooling1| dB(A)| 47
Compressor Type| INVERTER-driven twin rotary
Compressor Model| SNB172FWHM1
Compressor Rated Load Amps| A| 7
Compressor Locked Rotor Amps| A| 11.0
Compressor Oil [Type // Charge]| oz.| FV50S // 23
External Finish Color| Ivory Munsell 3Y 7.8/1.1
Base Pan Heater| N/A
Unit Dimensions| W x D x H: In. [mm]| 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943]
Package Dimensions| W x D x H: In. [mm]| 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033]
Unit Weight| Lbs. [kg]| 151 [68]
Package Weight| Lbs. [kg]| 176 [80]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum / Minimum]
| °F| 115 DB / -40 DB

Refrigerant

| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 7.0, 11.0
Maximum Pre-Charged Piping Length| Ft. [m]| 70.0 [20.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.3 [22.5]

NOTES:

AHRI Rated Conditions

(Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB

  • ndoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
  • Wind baffles required to operate below 23°F DB in cooling mode.
  • Cooling-only system with advanced wind baffle: -40°F – 115°F.
  • Refer to wind baffle documentation for further information.
  • utdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
  • The system cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
  • Blue Fin Coating Standard from 2022 production:
  • PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
  • PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****

SPECIFICATIONS: PLA-A30EA7 & PUY-A30NHA7

Piping

| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
---|---|---|---
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Maximum Piping Length| Ft. [m]| 225 [68]
Maximum Height Difference| Ft. [m]| 100 [30]
Maximum Number of Bends| 15

NOTES:

AHRI Rated Conditions

(Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
  • Wind baffles required to operate below 23°F DB in cooling mode.
  • Cooling-only system with advanced wind baffle: -40°F – 115°F.
  • Refer to wind baffle documentation for further information.
  • Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
  • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
  • Blue Fin Coating Standard from 2022 production:
  • PU(Y/Z)-A(12/18)NKA7 – Beginning with serial number 12U*****
  • PU(Y/Z)-A(24/30/36/42)NKA7 – Beginning with serial number 1ZU*****

INDOOR UNIT ACCESSORIES: PLA-A30EA7

Control Interface

| 3-Pin Connector| □ PAC-715AD
---|---|---
Airzone ZBS Wired Blueface Principal Controller White| □ AZZBSBLUEFACECB
Airzone ZBS Wired Blueface Principal Controller White| □ AZZBSBLUEZEROCB
Airzone ZBS Wired Lite Controller White| □ AZZBSLITECB
Airzone ZBS Wireless Lite Controller White| □ AZZBSLITERB
Airzone ZBS Wireless Think Controller White| □ AZZBSTHINKRB
BACnet® and Modbus® Interface| □ PAC-UKPRC001-CN-1
CN24 Relay Kit| □ CN24RELAY-KIT-CM3
IT Extender| □ PAC-WHS01IE-E
kumo station® for kumo cloud®| □ PAC-WHS01HC-E
Remote Operation Adapter‡| □ PAC-SF40RM-E
Thermostat Interface| □ PAC-US444CN-1
Thermostat Interface| □ PAC-US445CN-1
USNAP Adapter| □ PAC-WHS01UP-E
Wireless Interface for kumo cloud®| □ PAC-USWHS002-WF-2

Remote Sensor

| Flush Mount Remote Temperature Sensor| □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor| □ PAC-USSEN001-FM-1
Remote Temperature Sensor| □ PAC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud®| □ PAC-USWHS003-TH-1

Wired Remote Controller

| Deluxe Wired MA Remote Controller†| □ PAR-40MAAU
Simple Ductless Wired Remote Controller| □ PAC-SDW01RC-1
Simple MA Remote Controller†| □ PAC-YT53CRAU-J
Touch MA Controller†| □ PAR-CT01MAU-SB

Wireless Remote Controller

| kumo touch™ RedLINK™ Wireless Controller| □ MHK2
Lockdown bracket for remote controller| □ RCMKP1CB
Wireless MA Receiver| □ PAR-FA32MA-W
Wireless MA Remote Controller| □ PAR-FL32MA-E
Wireless Remote Contoller| □ PAR-SL101A-E
Wireless Signal Receiver Panel| □ PAR-SR4LU-E
Casement| Multi-function Casement| □ PAC-SJ41TM-E

Condensate

| Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]| □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor| □ X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI

Disconnect Switch

| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ PLP-41EAEU

Lineset

| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E

OUTDOOR UNIT ACCESSORIES: PUY-A30NHA7  Air

Air Outlet Guide Air Outlet Guide (1 Piece) □ PAC-SG59SG-E

Centralized Drain Pan

| Centralized Drain Pan| □ PAC-SG63DP-E
Drain Pan| □ PAC-SG64DP-E

Control/Service Tool

| Control/Service Tool| □ PAC-SK52ST
M- & P-Series Maintenance Tool Cable Set| □ M21EC0397
USB/UART Conversion Cable (Required for all laptop connection)| □ M21EC1397
Hail Guards| Hail Guard| □ HG-A6

M-NET Converter

| M-NET Converter| □ PAC-SJ85MA-E
M-NET Converter| □ PAC-SJ95MA-E

Mini-Split Wire

| 14 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S144-250
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S144-50
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll| □ S164-250
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll| □ S164-50
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| □ ULTRILITE2

Stand

| 18” Single Fan Stand| □ QSMS1801M
24” Single Fan Stand| □ QSMS2401M
Condenser Wall Bracket| □ QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1201M

Wind Baffle

| Front Wind Baffle| □ WB-PA5
Rear Wind Baffle| □ WB-RE5
Side Advanced Wind Baffle| □ WB-SD5

DIMENSIONS

INDOOR UNIT DIMENSIONS: PLA-A30EA7MITSUBISHI-ELECTRIC-PUY-
A30NHA7-Ceiling-Cassette Air-System -fig-1 MITSUBISHI-ELECTRIC-PUY-A30NHA7-Ceiling-Cassette Air-
System -fig-2

OUTDOOR UNIT DIMENSIONS: PUY-A30NHA7

  1. FREE SPACE (Around the unit)
  2. The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc.
  3. SERVICE SPACE
  4. Dimensions of space needed for service access are shown in the below diagram
  5. FOUNDATION BOLTS
  6. Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.)
  7. PIPING-WIRING DIRECTIONS
  8. Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and BelowMITSUBISHI-ELECTRIC-PUY-A30NHA7-Ceiling-Cassette Air-System -fig-4

Example of Notes

  1. Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F)
  2. Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F)
    • Indication of STOP VALVE connection locationMITSUBISHI-ELECTRIC-PUY-A30NHA7-Ceiling-Cassette Air-System -fig-5MITSUBISHI-ELECTRIC-PUY-A30NHA7-Ceiling-Cassette Air-System -fig-56 MITSUBISHI-ELECTRIC-PUY-A30NHA7-Ceiling-Cassette Air-System -fig-7

1340 Satellite Boulevard Suwanee, GA 30024

FORM# PLA-A30EA7 & PUY-A30NHA7 – 202304

Specifications are subject to change without notice

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals