Table of Contents
- Gude SP 15000 Inox Submersible Sewage Pump
- DELIVERED ITEMS
- SERVICE CONNECTION
- STARTING-UP THE MACHINE
- ENGINE PROTECTION
- AUTOMATIC OPERATION
- OPERATION
- NON-STOP OPERATION
- TRANSPORT / STORAGE
- Technical Data
- Safety Instructions
- Maintenance
- Service
- Inspection and maintenance plan
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Gude SP 15000 Inox Submersible Sewage Pump
Please read the instructions carefully before starting the machine.
DELIVERED ITEMS
SERVICE CONNECTION
STARTING-UP THE MACHINE
ENGINE PROTECTION
AUTOMATIC OPERATION
OPERATION
NON-STOP OPERATION
TRANSPORT / STORAGE
Technical Data
Read and understand the operating instructions before using the appliance. Familiarise yourself with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. The operator is responsible for accidents or risks to third parties. In case of any doubts about connection and operation refer please to our customer center Children over the age of 8 and persons with reduced physical, sensory or mental capabilities or with a lack of experience and/or knowledge may only use the machine when supervised or after being instructed on the safe use of the machine and understanding the risks arising from such use. Children may not play with the machine. Children may not clean or service the machine without being supervised.
Specified Conditions Of Use
The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions. Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.
- The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
- Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
- Do not use the pump for drinking water!
- The pump must not be connected to the existing water-supply network as a pressure-boosting device.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before
using the appliance.
Qualification: Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age: Persons over 16 years of age can only work on the appliance.
An exception includes youngsters trained in order to reach knowledge under the
supervision of the trainer during occupational education.
Training: Using the appliance only requires corresponding training by a
professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. For the sake of an eventual accident, in
accordance with DIN 13164, a workplace has to be fitted with a first-aid kit.
It is essential to replace any used material in the first-aid kit immediately
after it has been used. If you seek help, state the following pieces of
information:
- Accident site
- Accident type
- Number of injured persons
- Injury type(s)
Symbols
- Warning/caution!
- Read the Operating Instructions
- Before carrying out any work on the machine, disconnect the plug from the socket.
- Cable pulling/transport prohibited
- Staying in the transportation medium prohibited
- Warning against dangerous electric voltage
- Warning against automatic starting
- Accessory – Not included in the standard equipment, available as an accessory.
- CE marking
- Any damaged or disposed of devices must be delivered to the appropriate collection centers.
- Protect against humidity
- This side up
Safety Instructions
WARNING!
Electric shock! There is a risk of an injury caused by electric shock! Always
keep children and unauthorized persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max.
stray current of 30mA). Before putting it into operation, a qualified
electrician must check whether the electric safety measures required are in
place. Any national regulations in this regard must be complied with. Electric
connection to a socket. It is necessary to make sure the connecting socket was
not near water and humidity and that the plug was protected against humidity.
Check the voltage. Technical data given on the type label must correspond with
the electric network voltage. Only use splash-proof extension cables approved
for outdoor purposes. Do not grab the feeder cable, plunge the pump, lift or
carry it while it is connected to the grid! Check the cable and/or socket for
damages before the appliance putting into operation. To avoid danger, a
damaged mains supply pipe must be replaced by the manufacturer. Do not under
any circumstances attempt any repair yourself. Protect the feeder cable from
excessive temperatures, oil and sharp edges.
Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures. If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.). The pump must not in any case run without fillings. Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it. The temperature of the drained liquid must not exceed +35 °C. If the lubricant escapes the fluid could become contaminated. If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed. The user is responsible to third parties if pump (dumping stations, etc.) is used.
Maintenance
Before carrying out any work on the machine, disconnect the plug from the socket. Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug. The machine must not be used under any circumstances if the machine or the safety devices are damaged. To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals. At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with the appropriate oil (for example, vegetable oil). If the device is defective, the repair has to be made exclusively by customer service. Use only original accessories and original spare parts. Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.
Disposal
Disposal notes are based on the icons placed on the machine or on its package.
Any damaged or disposed of devices must be delivered to the appropriate
collection centers.
Transport packaging disposal
The packaging protects the machine against damage during transport. Packaging
materials are usually chosen based on environmental aspects and waste
treatment principles and are therefore recyclable. Returning the packaging
into material circulation saves raw materials and reduces waste production.
Parts of packaging (e.g. foils, styropor®) can be dangerous for children.
Risk of suffocation!
Keep parts of the packaging out of reach of children and dispose them as soon as possible.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months
applies to private use and commences on the day of purchase of the device. The
guarantee solely covers inadequacies caused by material defect or
manufacturing defects. An original payment voucher with the date of the sale
needs to be submitted for any claim in the guarantee period. The guarantee
does not cover any unauthorized use such as appliance overloading, use of
violence, or damage as a result of any unauthorized interference or caused by
foreign items. Failing to follow the operating and assembly instructions and
common wear are also not included in the guarantee.
Important information for the customer
Please be sure to know that returning the product in or after the warranty
period must be made in the original packaging.
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:
Serial No.:
Art. No:
Year of production:
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
Inspection and maintenance plan
Failure removal
Before eliminating any machine failure, turn the machine off and unplug it.
Failures| Causes| Removal|
---|---|---|---
Engine does not start| No power supply. Blocked pump wheel
Floating switch in shutdown position
| Check the voltage
Visually inspect the pump wheel for foreign objects
Check the water level
|
Pump does not suck| Pump without water Water level too low
Blocked pump wheel
| Let the air bubbles release 4
Switch the pump off, water level must go up. Remove the obstruction
|
Thermal detector swit- ching the pump off
5
| Dirty strainer
Water temperature too high
Pump running continuously at maximum pressure.
| Clean the strainer and let the pump cool down
Reduce the water temperature Make more breaks
|
Insufficient amount of| Plugged strainer| Clean the strainer|
water pumped| Water level quickly drops down| Ensure sufficient inflow|
Maximum head of delivery exceeded| Check the transport line 3|
|
| Broken piping| Check the transport line|
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned
appliances correspond-at the type of construction being launched-to the
appropriate basic safety and hygienic requirements of EC Directives. In case
of any change to the appliance not discussed with us the Declaration expires.
Appropriate EU Directives
- 2014/35 EU
- 1935/2004/EC
- 2011/65/EU&2015/863EU
- 2016/425/EU (PPE)
- 2015/1188/EU
- 2006/42 EC
- 2014/30/EU
- 1907/2006/EC
- 2016/426/EU
- 2019/1784/EU
- 2014/29/EU
- Annex IVM
- Notified Body Name:
- No: Adress:
- 97/68/EC_&2016/1628/EU
- Emission No.:
- 2000/14/EC_2005/88/EC
Method of compliance assessment
Harmonized standards used
- EN 60335-1:2012+A11+A13+A1+A14+A2
- EN 60335-2-41:2003+A1+A2; EN ISO 12100:2010
- EN 62233:2008; EN 62321
- EK1 566-13;EK1 527-12 Rev.2
- EN 55014-1:2017
- EN 55014-2:2015
- EN IEC 61000-3-2:2019
- EN 61000-3-3:2013
Guaranteed sound power level
Measured sound power level
Managing Director
Just In Time Heimwerker-Maschinen-Vertriebs GmbH, Birkichstralße 6, 74549 Wolpertshausen, Germany
Authorized to compile the technical file
hagebau Handelsgesellschaft für Baustoffe mbH&Co. KG
Celler Straße 47, D-29614 Soltau
www.hagebau.de
Herstelle
Just in Time GmbH, Birkichstraße 6, D-74549 Wolpertshausen
References
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
- hagebau.de – Dein online Baumarktshop
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>