Ironcat G24 Wireless Mouse User Manual
- September 7, 2024
- ironcat
Table of Contents
Ironcat G24 Wireless Mouse
Button function
- Left click
- Right-click
- Wheel/Middle click
- Backward
- Forward
- DP/Polling rate button | Keyway for 1K dongle storage
- OFF: Turn off the Power
- ON: Turn on the power and DPI mode
- HZ: Turn on the power and Polling rate mode
- Hot-swap switch
Recommend operating environment
To ensure wireless performance, please keep the mouse and receiver less than 20cm, and keep the device more than 2m from another interference source (Such as a Wi-Fi router).
Connection
Wired mode
Wireless mode
DPI and polling rate setting
DPI Setting
Switch button 7 to ON, then use button 6 to change the DPI(total 6 levels)
1K polling rate setting (1K dongle)
Switch button 7 to HZ, then use button 6 to change the polling rate(a total of
44 levels
8K polling rate setting(8K dongle)
Switch button 7 to HZ, then use button 6 to change the polling rate(total 7
levels)
About battery
Battery status
According to the current battery level of the mouse, the 8K dongle changes
from green (100%) to Yellow (66%), orange (33%), and red (0%) gradually
change.
Charging
The indicator keeps turning off and only turns on when charging.
Kindly reminder
It is recommended to charge when the battery is below 33%.
Warning
It is not recommended to replace the battery of the G24 series mouse. Problems
caused by self-replacement batteries are not covered by the warranty.
1K pairing step
Steps 1: turn off the mouse and hold down buttons 1,2,3.
Step 2: turn on the mouse.
Step 3 : Release button 1,2,3 after the indicator starts blinking yellow
color.
Step4: plug the receiver into the computer by connecting the cable and
adaptor. and put the mouse close to the receiver, the indicator will turn off
and the mouse can work after pairing succeeds.
8K pairing step
Step1: turn off the mouse and hold down buttons 1,2,3.
Step 2: turn on the mouse.
Step 3: Release button 1,2,3 after the indicator starts to blink yellow
color.
Step4: plug the receiver into the computer by connecting the cable and
adaptor. and put the mouse close to the receiver, the indicator will turn off
and the mouse can work after pairing succeeds.
[Kindly reminder]: it is in 1K mode if the mouse indicator is red color
before yellow bink. you should switch to 8K mode before pairing by holding
down buttons 1 and 4, then turn on the mouse. the indicator will show a blue
color.
[Attention]: You should unplug the receiver before start pairing, and
replug the receiver after the mouse indicator blinks yellow color.
Hot-swap switch change
Step 1: take out the hot-swap modular.
Step 2: Change switch.
Step 2: Insert hot-swap modular.
Product Spec
- DPI setting:400/800/1600/2400/3200/6400
- Polling rate setting
- 1K: 125/250/500/1000Hz
- 8K: 125/250/500/1000/2000/4000/8000Hz
- Battery life: around 143hours
- Weight: around 65g
- Sensor: G24 PAW3395/G24 Pro PAW3950ES-KING
- Interface: USB/TYPE-C
- Cable length: around 1.8M
- Rating: 5V/500mA
- Connection: USB+2.4G wireless
- Left and right switch: HUANO blue shell pink dot
- Acceleration: 50G
- IPS:G24 650ips/G24 Pro 750ips
- LOD: G24 1,2mm/G24 Pro 0.7-1-2mm.
- Encoder: TTC gold dust-proof
- Glides: 100% PTFE enhanced version
- Surface: Skin-like coating.
- Suggest hand size: 17~19CM or below
- Size: around 122x67x42.5mm
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation. Any changes or modifications not expressly
approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, under Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used by the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>