RS17 P Control Board Panel For Swing Gates Instruction Manual

June 12, 2024
RS17 P

RS17 P Control Board Panel For Swing Gates

Product Information

The RS17.P is a control panel designed for swing gates operating at 24 V DC with an encoder EKKO 204D. It complies with Directive 2002/96/EC (WEEE). The control panel features a battery charger, integrated receiver, obstacle detection system, input diagnostics LED, and a switching power supply. It also has a maximum capacity of 50 remote controls and is equipped with short- circuit protection Enclosure Sizes

Technical Data

  • Power supply: 120/230 Vac
  • Motor power supply voltage: 24 V DC
  • Maximum motor power: 80W
  • Output for flashing light: 12 V AC 15 VA
  • Electrical lock output: 24 V DC 10 W
  • Accessories power supply: 24 Vdc 300 mA
  • Receiver memory: Not specified
  • Receiver frequency: 433 MHz
  • Remote controls code: Not specified
  • Fuse F1: Not specified
  • Fuse F2: Not specified
  • Operating temperature: Not specified

System Type

The required cable cross-sections for cable routing are as follows:

| Cable Cross-Section
---|---
A| 2×2.5 mm2 + 3×0.5 mm2 (encoder)
B| 2×2.5 mm2
C| 4×0.5 mm2 + RG58
D| 3×2.5 mm2
E| 2×2.5 mm2
F| Not specified
G| Not specified

Description of the Terminal Blocks

The terminal blocks are labeled with different numbers and symbols.
Please refer to the user manual for detailed information on each terminal block and its functions.

Example:

  • F1 – Description: Not specified
  • A – Description: Linear actuator
  • 21, 22, 25, etc. – Description: Not specified

Note:

The cable connecting the encoder to the control panel must not exceed a length of 10 m and should not have any shielding. For encoder cabling longer than 10 m but no longer than 15 m, a shielded cable must be used.

Product Usage Instructions

  1. Ensure that the swing gates are properly installed and connected to the control panel.
  2. Connect the power supply to the control panel. The power supply voltage should be 120/230 Vac.
  3. Connect the motor power supply to the control panel. The motor power supply voltage should be 24 V DC.
  4. If required, connect an electrical lock to the control panel The electrical lock should have a negative and positive connection.
  5. If using a flashing light, connect the flashing light with the aerial to the control panel. The flashing light should have a positive connection.
  6. If using accessories such as photocells or a gate open warning light, connect them to the control panel. The accessories should have a negative and positive connection.
  7. If using remote controls, program them by following the instructions provided in the user manual.
  8. Ensure that all connections are secure and properly insulated.
  9. Refer to the user manual for further instructions on customizing the deceleration distance, obstacle detection system, and input diagnostics LED.

WARNINGS FOR THE INSTALLER

  • Carefully read all the instructions and warnings in this document as they provide important information regarding safe installation, operation and mainte-nance.

  • After removing the packaging, check the condition of the equipment. The packaging must not be left within reach of children as it is potentially harmful. Installation must be carried out in accordance with national safety regulations.

  • This equipment must be used only for the purpose for which it was expressly intended, i.e. for the automation of motors for roller blinds and for controlling resistive loads such as lights. Any other use is considered improper and therefore hazardous. The manufacturer declines all liability for damage caused by improper, incorrect or unreasonable use.

  • Always disconnect the equipment from the power supply at the main switch before performing maintenance or cleaning procedures.

  • In the event of faults and/or malfunctions, disconnect the equipment from the power supply at the switch and do not tamper with it. For repairs, contact only a service centre authorized by the manufacturer. Failure to observe the above may jeopardize the safety of the equipment.

  • All equipment within the system must be used exclusively for the purpose for which it is intended.

  • This document must always be kept with all paperwork regarding the installation.

  • Directive 2002/96/EC (WEEE).
    The crossed out wheelie bin symbol marked on the equipment indicates that, at the end of its useful working life, the product must be handled separately from household refuse and must therefore be assigned to a differentiated collection centre for electrical and electronic equipment or returned to the dealer upon purchase of a new, equivalent item of equipment.

  • The user is responsible for ensuring the equipment is disposed of through the correct channels when no longer in service. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of recycling materials used in manufacture. For further details regarding available collection systems, contact your local waste disposal service or the shop from which the equipment was purchased.

  • Risks associated with substances considered hazardous (WEEE).

  • According to the new WEEE Directive, substances which for some time have been widely used in electrical and electronic equipment are considered hazardous to human heath and the environment. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious dis-posal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of recycling materials used in manufacture.

Enclosure sizes

Product features

  • Control panel for governing swing gates for 24 Vdc gearmotors with encoder with battery charger and integrated receiver. The control panel:
  • enables customizing the deceleration distance
  • is equipped with an obstacle detection system
  • is equipped with input diagnostics LED
  • is equipped with an integrated 433 MHz receiver with a maximum capacity of 50 remote controls
  • is equipped with short-circuit protection
  • is equipped with a switching power supply

Technical data

Power supply 120 to 230 Vac
Motor power supply voltage 24 Vdc
Maximum motor power 80 to 80 W
Output for flashing light 24 Vdc 10 W max
Electrical lock output 12 Vsc 15 VA max
Accessories power supply 24 Vdc 300 mA
Receiver memory 50 remote controls
Receiver frequency 433 MHz
Remote controls code Rolling code or fixed
Fuse F1 Line protection 5×20 mm T1.6 A
Fuse F2 Accessories protection 5×20 mm T8A
Operating temperature -10 to +50°C

System type

For the sizing of the cable routing, the required cross-sections of the cables are shown below

Legend

  • A – Linear actuator
  • B – Control unit
  • C – Flashing light with aerial
  • D – 2-channel remote control
  • E – Pair of photocells
  • F – Selector
  • G – Electrical lock

Description of the terminal blocks

Terminal Description Rated data
L Phase

120 to 230 V AC

| Earth
N| Neutral
21| Opening motor 1| 24 V DC 80W
22| Closing motor 1
25| Opening motor 2| 24 V DC 80W
26| Closing motor 2
18| Electrical lock negative| 12 V AC 15 VA
19| Electrical lock positive
11| Flashing light positive| 24 V DC 10 W
0| Accessories negative
17| Photo-test or gate open warning light positive|

24 V DC 120 mA

0| Accessories negative
Terminal| Description| Rated data
---|---|---
+E| Encoder positive|
41| Motor 1 encoder signal
45| Motor 2 encoder signal
-E| Encoder negative

Note:
The cable connecting the encoder to the control panel must be no longer than 10 m and have no shielding. For encoder cabling longer than 10 m and in any case no longer than 15 m, a shielded cable must be used.

Terminal Description Rated data
1 Accessories positive 24 Vdc 300 mA
0 Accessories negative
+B Emergency battery positive
-B Emergency battery negative
52 Pedestrian (N.O.)
51 Step by step (N.O.)
62 Photocell when clos- ing (N.C.)
63 Photocell (N.C.)
64 Sensitive edge (N.C.)
61 Stop (N.C.)
99 Common inputs
ANT Aerial signal
Aerial earth

Description of output function:

  •  Accessories power supply voltage: Permanent 24 Vdc output

Electrical lock:

  • 12 Vac output powered for 2 s at the start of the opening movement

Flashing light:

  • 24 Vdc output powered when the gate is moving
  • Photo-test or gate open warning light:
  • 24 Vdc output for signaling gate status or performing the safety test: With DIP 8 = OFF it is Gate Open Warning Light
  • Not powered with gate closed
  • Powered continuously with gate open or moving With DIP 8 = ON it is Photo-test
  • Used for the power supply of the transmitters of the safety devices.

Note:

  • Using the photo-test requires specific wiring of the safety devices (par. 4.3).
Description of input function

Step by step (N.O.):

  • Sequential command input, to control the complete travel of the gate. It works with the following cycle: open-stop-close-stop or open-stop-close-open according to the setting of DIP 3

Pedestrian (N.O.):

  • Command input for opening to the pedestrian distance

Stop (N.C.):

  • Gate stops, does not turn off automatic closing.
  • If not used, jumper with the common (99)

Photocell when closing – PHC (N.C.):

  • Photocell when closing, with the gate stationary it allows opening, when opening it does not trigger, with the gate open it does not allow closing and on release it resets the automatic closing time, when closing it commands immediate reopening.
  • If not used, jumper with the common (99)

Photocell – PH (N.C.):

  • Photocell, active both when closing and when opening, with the gate stationary it does not allow opening, during opening it stops the movement and on release it continues opening, with the gate open it does not allow closing and on release it resets the automatic closing time, when closing it stops the movement and on release it commands reopening.
  • If not used, jumper with the common (99)

Sensitive edge (N.C.):

  • Safety sensitive edge, N.C. dry contact, with the gate stationary it does not allow opening, when opening it disengages, with the gate open it does not allow closing and on release it resets the automatic closing time, when closing it disengages.
  • If not used, jumper with the common (99)

Connecting accessories

Key switch and control devices

  • Photocells and photocells when closing
  • Photocells and photocells when closing with photo-test active (DIP 8 = ON)

Sensitive edge

  • Stop push button

Trimmer functions

Trimmer Description
MOT 1 Power of motor 1 (turn the trimmer clockwise to increase the

power)
MOT 2| Power of motor 2 (turn the trimmer clockwise to increase the power)

Functions of the buttons:

Button Description
PROG Button for programming the travel
MRX Button for programming or deleting remote controls
51 Step-by-step command button

DIP-switch functions

DIP Function Status Description
DIP 1 Close immediately OFF Close immediately off
ON Close immediately on:

The engagement and subsequent disengagement of the photocell when closing, while opening or during the pause time causes the gate to reclose immediately at least 3 s after full opening, regardless of the set automatic closing time.

DIP 2| Automatic closing| OFF| Automatic closing off
ON| Automatic closing on
DIP 3| Step-step logic| OFF| 2 steps: step-by-step (term. 51 and radio) with logic in 2 steps (open – close – open)
ON| Step-by-step command (term. 51 and radio) with logic in 4 steps (open – stop – close – stop

– open – stop)

DIP 4| Apartment block| OFF| Apartment block off
ON| Apartment block on (while the gate is opening, you cannot stop the movement with a radio command or with inputs 51 (step-by-step) and 52 (pedestrian).

With automatic closing on (DIP-switch 2 = ON) and the gate open, an additional step-by- step command (terminal 51 or radio command) renews the pause time and if input 51 remains engaged the control panel suspends the pause count until the input is disengaged

(for connecting any coils or a timer).

DIP 5| Slowdown distance| OFF| Slowdown distance at 10% of the travel
ON| Slowdown distance at 20% of the travel
DIP 6| Hammering| OFF| Hammering for electrical lock off
ON| Hammering for electrical lock on (required when using an electrical lock).

Activate anyway if the leaves are having difficulties during the initial opening phase, for

instance when temperatures are below zero and/or there is light friction.

DIP 7| Status of gate at reset| OFF| Status of gate closed at reset
ON| Status of gate open at reset
When the power supply is restored, a step-by-step command causes closing and if automatic closing is on (DIP-switch 2 = ON), closing occurs after the pause time
DIP 8| Photo-test| OFF| Photo-test off
ON| Photo-test on

At the start of each action, the control panel checks the operation of the photocells.

It requires specific wiring

DIP 9| Normal speed| OFF| High normal speed
ON| Low normal speed
DIP 10| Number of motors| OFF| Double swing gate leaf (M1 and M2 on)
ON| Single swing gate leaf (only M1 on)

LED functions

LED Status Description
PWR OFF Mains power supply not present
ON Mains power supply present
MRX 1 blink Saving a new remote control
2 blinks Saving a remote control already in memory
3 blinks Deleting a remote control
4 blinks Radio memory full
5 blinks Savable remote control not in memory
10 blinks Complete deletion of the radio memory
51 OFF Step-by-step input (term. 51) not engaged
ON Step-by-step input (term. 51) engaged
52 OFF Pedestrian input (term. 52) not engaged
ON Pedestrian input (term. 52) engaged
61 OFF Stop contact (term. 61) open (engaged)
ON Stop contact (term. 61) closed (not engaged)
62 OFF Photocell engaged when closing (term. 62 open)
ON Photocell not engaged when closing (term. 62 closed)
63 OFF Photocell engaged when opening (term. 63 open)
ON Photocell not engaged when opening (term. 63 closed)
64 OFF Sensitive edge engaged (term. 64 open)
ON Sensitive edge not engaged (term. 64 closed)

Time setting

  • The control panel is programmed by default with the following times:
  • automatic closing: 30 s
  • offset for opening: 3 s
  • offset for closing: 6 s
  • To change the default times, follow the procedure below (the phases for installing a double swing leaf gate have a grey background; if there is a single leaf, the leaf offsets are not programmed)
  • The control panel does not need travel setting as this is automatically measured with each action. For this to happen, run a complete open-close action (it will take place at reduced speed as the control panel does not know the exact position of the leafs).
  • NOTE: In order to perform this procedure, the gate must be stationary.
  • CAUTION! THE SAFETY DEVICES ARE DISABLED WHILE CARRYING OUT THIS PROCEDURE
No. Pressing push button Phase Description
1 PROG Procedure activation Press and hold down the PROG push button

until the flashing light comes on steady, then release

the button, and the automatic gate system will now close the gate.

2| –| Leaf closing| Unless the leafs are already closed, the first action MUST be CLOSING; otherwise, cut off the power supply to the control panel and invert the cables of the motor that opens instead of closing.

N.B. DO NOT INVERT THE ENCODER CABLES.

3| –| Opening M1| M1 starts to open and the control panel starts the count of the offset for opening
4| 51| Setting the offset for opening| After the desired time, press and release button 51 to set the offset for opening (if not

pressed, after 40 s M2 will start automatically). M2 starts opening

5| –| Completion of opening| M1 and M2 continue to open at low speed until they reach the mechanical stops on opening
6| 51| Setting the pause time| With the gate stationary in the fully open position, the automatic closing time count starts, after the required length of time has passed, press and release push button 51, the control panel will save the elapsed time (max. 250 seconds)
7| –| Closing M2| M2 starts to close and the control panel starts the count of the offset for closing
8| 51| Setting the offset for closing

M1 starts closing

| After the desired time, press and release button 51 to set the offset for closing (if not pres- sed, after 130 s M1 will start automatically).
9| –| Completion of closure and end of programming| The automation completes the closure when it reaches the closing mechanical stops and the

flashing light goes out to signal that the travel programming procedure has been exited.

Note:
If you want to return the control panel to default, perform the following procedure:

  1. Disconnect the power to the control panel
  2. Press and hold the PROG button.
  3. Reconnect the power to the control panel and wait for the flashing light to come on steady.
  4. After 3 sec., release the PROG button. The flashing light will turn off.
  5. The control panel is now set with the default times.

Remote control programming
Note: Remote control programming can only be done with the automatic gate system stationary
Step-by-step programming:

No. Pressing push button Signal MRX LED Description
1 MRX Off Press and hold down the MRX push button for no more than 7

s
2| MRX+ remote control| –| With the MRX push button still pressed, press the button of the remote control to be saved
3| –| 1 blink| A button of the saved remote control (new remote control)
2 blinks| A button of the saved remote control (remote control already in memory)

Programming the pedestrian:

No. Pressing push button Signal MRX LED Description
1 MRX+PROG Off Press and hold down the MRX and PROG push buttons for

no more than 7 s
2| MRX+PROG+remote control| –| With the MRX and PROG push buttons still pressed, press the button of the remote control to be saved
3| –| 1 blink| Button of the saved remote control (new remote control)
2 blinks| Button of the saved remote control (remote control already in memory)

Deleting a remote control

No. Pressing push button Signal MRX LED Description
1 MRX On steady Press and hold down the MRX push button for at least

7 s until the MRX LED comes on steady
2| MRX+ remote control| –| With the MRX push button still pressed, press the button of the remote control to be deleted
3| –| 3 blinks| Deletion successful

Complete deletion of the receiver

No.| Pressing push button| MRX LED

indicator

| Description
---|---|---|---
1| MRX| Flashing light| Press and hold down the MRX push button for at least 14 s until the MRX LED starts flashing
2| –| 10 blinks| Complete deletion of the receiver

Note:
After deleting all the remote controls, the first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with a fixed code.

Troubleshooting

Problem Cause Solution
The automation system does not work No mains supply Check the power

line switch
Blown fuses| Replace blown fuses with others of the same value
Control and safety inputs not working| Check the diagnosis LEDs (FCL, FOP, COSTA and STOP must be on)
You cannot save the remote controls| Safety devices open| FCL, FOP, COSTA and STOP must be on
Batteries of the remote control discharged| Replace the batteries
Remote control not compatible with the first one

saved

| The first saved remote control configures the control panel to save only rolling-code remote controls or only dip-switch remote controls
Reached memory saturation| Delete at least one remote control or add an external receiver (maximum capacity 50 remote controls)
As soon as the gate starts, it stops and reverses| Motor torque not sufficient| Increase the power via trimmer MOT 1 for motor M1 and MOT 2 for M2
Movement of one of the 2 motors is reversed| Wrong wiring| Check the motor wiring
During calibration the motor M1 starts and stops after 1 second| Encoder 1 wiring reversed with encoder 2| Check the encoder wiring
With the electrical lock the motor 1 is not able to start opening or does not close completely| Electrical lock unable to get freed| Set DIP-switch 6 in ON position (hammering on)
After a command the flashing light blinks 6 times but the gate fails to open| Photo-test check failed| Check the electrical wiring (see section 4) and DIP-switch 8 Check the alignment of the photocells
The flashing light does not work

during the movement

| No mains power supply and motors on battery operation| Check the mains power supply
The gate moves at slowdown speed| Probable 230 V AC mains failure| Run 1 complete open/close action
The gate opens one leaf at a time

with an offset of 40s

| The leaf offset has not been programmed| Return the working times to default or if necessary program

them.

The gate detects an obstacle even when it is not there| – Incorrect bracket dimensions

– Force trimmer too low

– Gate mechanics stiff

| – Check dimensions

– Raise force trimmer

– Service the gate

Closing one leaf at a time| – Previous no mains

– Reset action in case of overlapping leafs.

| Wait for the operation to be completed, the gate will be reset automatically
The leaves have difficulty during

the initial opening phase

| Temperatures below zero and/or there is light friction| Set DIP 6 to ON

EC DECLARATION OF CONFORMITY

  • (Declaration of incorporation of partly completed machinery annex IIB 2006/42/EC)
    • No. : ZDT00737.00
  • The undersigned, representing the following manufacturer Vimar SpA V Viale Vicenza, 14 – 36063 Marostica (VI) Italy herewith declares that the products

Electronic control unit

Articles

  • Trade mark Type ref. Cat. ref. Description EN *
  • Elvox RS16 RS16 24V ACTO 404D control card
  • Elvox RS17 RS17 24V EKKO 204D control card
  • Elvox RS17.An RS17.A Switchboard 24V EKKO ART 204D
  • Elvox RS17.P RS17.P Switchboard 24V EKKO 204D
  • when installed with the appropriate accessories and/or enclosures for devices are in conformity with the provisions of the following EU directive(s) (including all applicable amendments)
  • Machinery Directive 2006/42/CE EN 60335-2-103 (2015), EN 13241 (2003) + A2 (2016), EN 12453
  • LV Directive 2014/35/EU (2002)
  • R&TTE Directive 1999/5/CE EN 301 489-3 (2013), EN 300 220-2 (2012)
  • EMC Directive 2014/30/EU EN 61000-6-1 (2007), EN 61000-6-3 (2007) + A11 (2011)
  • Further hereby declares that the product must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of Directive 2006/42/EC, where appropriate.
  • Declares that the relevant technical documentation is compiled by Vimar SpA and in accordance with part B of Annex VII of Directive 2006/42/EC and the following essential requirements of this Directive are applied and fulfilled:
  • 1.1.1, 1.1.2, 1.1.3, 1.1.5, 1.1.6, 1.2.1, 1.2.2, 1.2.6, 1.3.1, 1.3.2, 1.3.3, 1.3.4, 1.3.7, 1.3.8, 1.3.9, 1.4.1, 1.4.2, 1.5.1, 1.5.2, 1.5.4, 1.5.5, 1.5.6, 1.5.7, 1.5.8, 1.5.9, 1.6.1, 1.6.2, 1.7.1, 1.7.2, 1.7.3, 1.7.4.
  • I undertake to make available, in response to a reasoned request by the national authorities, any further supporting product documents they require.
  • Marostica, 24/02/2015 The Managing Director
  • Note: The contents of this declaration correspond to what was declared in the last revision of the official declaration available before printing this manual.
  • The text herein has been re-edited for editorial purposes. A copy of the original declaration can be requested from Vimar SpA
  • Viale Vicenza 14
  • 36063 Marostica VI – Italy
  • RS17.P installer EN 02 2203 www.vimar.com