RAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V Bronze Instructions

June 17, 2024
RAB

RAB Logo INSTRUCTIONS
SLIM® 37W INSTALLATIONRAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V
Bronze SLIM37

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing the fixture. No user serviceable parts inside.

MOUNTING

To ensure weatherproof seal, apply weatherproof silicone sealant around the edge of the Housing and/or Junction Box shown in Fig 1. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries.

  1. Loosen Door Screws and open the Door. Screws will remain in place.
  2. Tether Cable provided for hands free wiring.
  3. Knock out appropriate Slots when mounting to Junction Box (by others) or Lag Bolt to mounting surface using locations shown in Fig 2. Use Leveling Bubble to level fixture.
  4. Feed supply wires through Junction Box (by others). Check that the Gasket is fully sealed.
  5. Make sure Housing Gasket is properly seated. Close and tighten the Door Screws. Silicone all Plugs and unused conduit entries.
  6. If outdoor surface is irregular, use caulk to seal any gaps around the Housing.

RAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V Bronze -
MOUNTING

ON/OFF WIRING
Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz, except fixtures factory ordered with a 120V photocell (/PC) and 277V photocell (/PC2) and fixtures factory ordered with a 120V swivel photocell (/PCS) or 277V swivel photocell (/PCS2) or 480V swivel photocell (/PCS4). Units ordered with (/480V) suffix are 480V.
Follow the wiring directions shown in Fig 3.

  1. Connect the Black fixture lead to the LINE supply lead.
  2. Connect the White fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground.

RAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V Bronze - MOUNTING
1

0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units ordered with (/480/D10) suffix are 480V, 50Hz or 60Hz. For 0-10V dimming, follow the wiring directions as shown in Fig. 4.

  1. Connect the black fixture lead to the LINE supply lead.
  2. Connect the white fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground.
  4. Connect the purple fixture lead to the (V+) DIM lead.
  5. Connect the pink fixture lead to the (V-) DIM lead.
  6. Cap the yellow fixture lead, if present. Do NOT connect.

NOTE: Do not connect DIM V+ (purple)/ DIM V- (pink) to line voltage or supply ground.

RAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V Bronze - MOUNTING
2

FULL CUTOFF/GUARD/SHIELD INSTALLATION

  1. Remove (4) Stainless Steel Screws from the Full Cutoff Hood as shown in Fig 5.
  2. Mount wire guard and/ or poly shield over the full cutoff hood with (4) #8-32 x 1/2” Stainless Steel Screws. Screws are provided with the accessory.
    Note: Guard, shield and full cutoff hood may be used together with (4)

    8-32 x 3/4” stainless steel screws (supplied by others).

RAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V Bronze - MOUNTING
3

GUARD/SHIELD INSTALLATION

  1. Remove left and right Cover Plates and discard as shown in Fig 6.
  2. Mount wire guard and/ or poly shield with (4) #8-32 x 1/2” Stainless Steel Screws. Screws are provided with the accessory.
    Note: Guard and shield may be used together.

RAB SLIM37 Wall Packs 4060 Lumens Slim 37W 480V Bronze -
Stainless

CLEANING

CAUTION: Be sure fixture temperature is cool enough to touch.
Do not clean or maintain while fixture is energized.

  1. Clean glass lens with non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Check that the line voltage at fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?
  3. Be sure the photocell, if used, is functioning properly.
    Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or

© 2023 RAB LIGHTING Inc.
SLIM37-IN-0923 73298-RAB
Easy Answers rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals