SEALEY SPB27W 27kg Lightweight Walk Behind Broadcast Spreader User Manual
- June 17, 2024
- SEALEY
Table of Contents
SEALEY SPB27W 27kg Lightweight Walk Behind Broadcast Spreader User Manual
Refer to instruction manual
SAFETY
√ Before each use, check that there is no damage to the spreader and that
all fixings are tight.
√ Replace or repair damaged parts. Use only recommended parts.
Unauthorised parts may be dangerous and will invalidate the warranty.
√ Ensure that the operator is fully trained and competent to operate the
spreader.
√ Ensure that all chemical safety instructions are adhered to when
handling products for use in the spreader. A full range of personal safety
equipment is available from your Sealey dealer.
√ Always distribute the load evenly.
√ Ensure all non essential personnel keep a safe distance when the
spreader is in use.
√ Keep hands and feet away from moving parts.
χ DO NOT overload the spreader – see Specification.
χ DO NOT leave unattended, especially when loaded.
χ DO NOT allow anybody to sit, stand, or ride on the spreader.
χ DO NOT allow untrained personnel to use the spreader.
χ DO NOT allow children to play in or climb onto the spreader.
χ DO NOT use on windy days when spreading seeds or herbicides.
χ DO NOT tow this spreader with a motorized vehicle of any sort.
χ DO NOT use the spreader for purposes other than for which it is
designed.
χ DO NOT operate the spreader when you are tired or under the influence
of alcohol, drugs or intoxicating medicines.
√ When loaded, DO NOT operate the spreader over edges, rough surfaces
etc. where the spreader is at risk of overturning.
- WARNING! Failure to comply with these instructions may result in damage to spreader or other property and/or personal injury
1 Hex Bolt4pcsM6x45
| 2 Hex Bolt M6x35
4pcs
| Hex Bolt2pcs M6x30
| Hex Bolt01pcM5x25
---|---|---|---
Carriage BoltM6x402pcs
| Round Head Bolt M4x201pc
| Lock Nut M610pcsM0
| Lock Nut M51pc0
Flat Washer 062pcs0
| Flat Washer 0122pcs
| Large Flat Washer 064pcs
| Split Pin1pc
R Pin1pc
| Axle Cap2pcs
| Wing Nut M62pcs
|
INTRODUCTION
Manufactured with a strong tubular steel frame and polypropylene dispensing hopper. Fitted with nylon gear and adjustable feed system. Sprays in 360° motion to cover a large area. Suitable for a variety of horticultural agents including grit, seed, salt, fertilizer and weedkiller.
Gear Box1P& Axl
| Hopper
1 pc
| Square Impeller
1 pc
---|---|---
Wheel Assembly
Frame
2pcs
| Support Leg
1 pc
| Handle Assembly
1 pc
Wheel
2pcs e Axle
1 pc
| Gauge and Lever
Assembly
1 pc
| Connect Tube2pcs.
ASSEMBLY
NOTE: Before assembly ensure there are no missing parts or fixtures.
Refer to fig.1.
Slide the Impeller (18) over the vertical axle on the gear box (16).
Secure the Impeller to the axle with a round head bolt M4x20 (6).
Refer to fig.2.
Insert the connecting tubes (25) into the support leg (20) and hold with hex bolt M6x45 (1).
Insert the other two hex bolts M6x45 (1) through the middle holes in the connecting tubes, ready for step 3.
Refer to fig.3.
Slide the wheel assembly frame (19) over the bolts already in the support leg assembly. Secure with 4 M6 lock nuts (7).
Refer to fig.4.
Slide the axle (23) through one wheel (22), frame and gearbox, through the other leg of the frame and then the other wheel.
Looking at the spreader from the front, ensure the axle (23) is inserted from the left, so that the hole in the end of the axle (23) lines up with the hole in the right hand side wheel.
Secure the right hand wheel (22) to the axle (23) with the split pin (12).
Attach the axle (23) to the gear box with the M5 hex bolt (4) and lock nut (8).
Insert axle caps (14) into the middle of the wheels (22).
Refer to fig.5.
Lower the hopper (17) over the axle and onto the frame and secure with 4 hex bolts (2), large flat washers (11) and lock nuts (7).
Refer to fig.6.
Attach the gauge and lever assembly (24) to the inside of the handle assembly (21). Secure with M6x30 hex bolts (3) and M6 lock nuts (7).
Refer to fig.7.
Slide the handle assembly around the support leg assembly and secure with carriage bolts (5), flat washers (9) and wing nuts (15).
Insert the bent end of the control clamp wire into the small hole in the lever assembly (A).
Remove the hex bolt from cable clamp then insert the control cable into the clamp (B,C).
Re-insert hex bolts to clamp control cable in place.
Move the lever (D) down to open the spreader slots in the bottom of the hopper. If the holes are not fully exposed, loosen the cable clamp (C) and adjust the cable.
Insert R-pin (13) through top of the vertical axle.
OPERATION
The spreader is designed to be pushed at three miles an hour, which is a brisk walking pace. Slower or faster speeds will change the spread pattern. Wet fertiliser will also change the spread pattern.
Use the Stop bolt on the gauge to ensure the same amount of distribution.
See figs.8 & 9
for suggested walking patterns depending on the level of coverage you require.
Always start walking prior to opening the flow control plate.
Every time you are ready to stop, or turn to make a new pass, close the flow control plate to stop dispensing the material and continue one more stride. This reduces waste and avoids damaging a lawn with over saturated product coverage.
To ensure consistent coverage, make sure each broadcast pattern slightly overlaps the previous one.
Make sure that any broadcast material does not come into contact with trees, shrubs and flowers that could be harmed by the material.
Clean the spreader thoroughly after each use paying particular attention to the shut off plate and the bottom of the hopper.
CALCULATING THE AMOUNT OF MATERIAL NEEDED. (refer to Charts ‘A’ & ‘B’)
To calculate the amount of material needed e.g lawn fertiliser, divide the coverage stated on the packaging by the weight of the fertiliser bag. For example, a 10lb bag of fertiliser with a coverage of 10,0000 sq. ft. will distribute 1lb of fertiliser every 1,000 sq.ft. at full rate or 1/2lb. of fertiliser every 1,000 sq. ft. at half rate.
For precalculated rates see Chart ‘A’ (Example: A 25lb bag with a 15,000 sq. ft. coverage requires 1.7lb of fertiliser per 1,000 sq.ft.
Use Chart ‘B’ to find the closest spreader setting. For example, 1.7lb per 1000 sq.ft. = spreader setting 8)
(CHART ‘A’) SQUARE FOOT COVERAGE PER BAG (LBS/1000 SQ.FT)
WEIGHT OF BAG (LBS)| 5000 SQ.FT COVERAGE| 10000 SQ.FT COVERAGE|
15000 SQ.FT COVERAGE
5| 1.0lb| 0.5lb| 0.3lb
10| 2.0lb| 1.0lb| 0.7lb
15| 3.0lb| 1.5lb| 1.0lb
20| 4.0lb| 2.0lb| 1.3lb
25| 5.0lb| 2.5lb| 1.7lb
30| 6.0lb| 3.0lb| 2.0lb
35| 7.0lb| 3.5lb| 2.3lb
40| 8.0lb| 4.0lb| 2.3lb
45| 9.0lb| 4.5lb| 3.0lb
50| 10.0lb| 5.0lb| 3.3lb
55| 11.0lb| 5.5lb| 3.7lb
(CHART ‘B’) SPREADER SETTINGS/SPREADER WIDTHS
MATERIALS TO BE USED| LBS/1000 SQ.FT| G/M²| SPREADER SETTING| SMALL PARTICLE SPREAD| MEDIUM PARTICLE SPREAD| LARGE PARTICLE SPREAD
GRIT SEED FERTILISER
WEED KILLER
E.T.C.
| 1| 5| 5| 5-6 ft| 6-9 ft| 9-12 ft
2| 10| 8| 5-6 ft| 6-9 ft| 9-12 ft
3| 15| 10| 5-6 ft| 6-9 ft| 9-12 ft
4| 20| 13| 5-6 ft| 6-9 ft| 9-12 ft
5| 25| 15| 5-6 ft| 6-9 ft| 9-12 ft
6| 30| 18| 5-6 ft| 6-9 ft| 9-12 ft
7| 35| 20| 5-6 ft| 6-9 ft| 9-12 ft
8| 40| 23| 5-6 ft| 6-9 ft| 9-12 ft
9| 45| 25| 5-6 ft| 6-9 ft| 9-12 ft
10| 50| 28| 5-6 ft| 6-9 ft| 9-12 ft
11| 55| 30| 5-6 ft| 6-9 ft| 9-12 ft
MAINTENANCE
After each use clean material out of hopper.
Rinse/dry inside and outside of spreader after each use.
Before operating make sure that the tyres are inflated to the correct pressure.
Periodically check all fastenings are tight.
Annually clean and lightly lubricate parts.
Touch up all scratched or worn painted metal surfaces.
To avoid damaging the spreader never exceed the rated load capacity of 27kg.
STORAGE
Before storing ensure that the spreader is clean and dry.
Store indoors or in a protected area during severe weather and in the winter months.
Never allow material to stay in the hopper for extended periods of time.
Environment Protection
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
sales@sealey.co.uk
www.sealey.co.uk
Read User Manual Online (PDF format)