Original manual. This manual belongs with the unit and must always be passed on together with the unit.
- Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
Safety information
Electrical connection
- Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
- The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
- For your own safety, please consult a qualified electrician.
- Only connect the unit if the electrical data of the unit and the power supply match.
- Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
- Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
- Protect open plugs and sockets from moisture.
Safe operation
- Operate the unit only when there are no people in the water.
- Never operate the unit if an electrical cable is defective!
- Do not carry or pull the unit by its power cable.
- A damaged connection cable cannot be replaced. Dispose of the unit.
- Never carry out technical changes to the unit.
- Only carry out work on the unit that is described in this manual.
- Only use original spare parts and accessories.
- Route lines in such a way that they are protected from damage and do not present a tripping hazard.
- Should problems occur, please contact the authorised customer service or OASE.
Use
The skimmer 250 removes coarse soiling from the pond surface. The integrated pump takes the pond water in via the skimmer flap and conveys the cleaned water back into the pond through the pump outlet. The surface soiling is retained by the basket. The Skimmer 250 is recommended for a maximum water surface area of 250 m².
Intended use
The Skimmer 250, in the following text termed unit, may only be used to clean normal pond water at a water temperature of +4°C to + 35°C. Do not use the unit in swimming ponds.
The unit floats on the water. To keep it in position, the enclosed wire cables
are fastened to the unit and either to the bank or to the pond bottom.
Anchoring the unit at the bank (A): Shorten the two wire cables to the desired
length. Form loops at the cable ends and fasten with the cable clamps (3).
Hook the cables into the eyebolts (4) at the skimmer housing by means of
bayonet hooks (1). Knock the two tent pegs (2) into the bank ground.
Important: Adhere to the specified bracing angles (6) to prevent the unit from
moving. Set the unit in the water and hook the cables to the tent pegs (2)
using the bayonet hooks (1). Attention: Pull relieve the connection cable (8)
and protect the power plug from moisture!
Anchoring the unit to the pond bottom (B): Shorten the two wire cables to the
desired length (minimum 5 m). Form loops at the cable ends and fasten with the
cable clamps (3). Hook the cables into the eyebolts (4) at the skimmer housing
by means of bayonet hooks (1). For anchoring to the pond bottom, screw the
enclosed threaded hooks (9) including the dowel, for instance, into two
sufficiently heavy stones. Hook both cables with bayonet hooks (1) in the
threaded hook (9), lower the stones to the bottom of the pond and set the unit
on the water. Attention: Pull relieve the connection cable (8) and protect the
power plug from moisture!
Switching on, switching off
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the
water and commencing work.
The unit switches on automatically when power connection is established.
Switching on: Plug the power plug (10) into the socket.
Switching off: Disconnect the power plug (10).
Cleaning
Disconnect the power plug (10) prior to starting cleaning work!
Empty out the retaining basket (11) at regular intervals, clean with clear
water, if necessary.
Clean the floating body (5) and the pump (18), as required, with clear water
using a soft brush.
Pump removal
Remove the retaining basket (11). Remove the brace (12) from the pump holder
(13). Remove the Tradux wall leadthrough (F) to be able to take out the power
cable. For this purpose, only loosen the four M5 Allen screws, then pull the
entire unit out of the leadthrough tube (15). Remove the Allen screws as well
as the rear (16) and front (17) retaining plates together with the sealing
insert (14). Pull the connection cable through the leadthrough tube (15). Pull
the pump (18) out of the pressure piece and remove from the floating body
(5).
Important: When reassembling the Tradux wall leadthrough (F), ensure that
the front (17) and rear (16) half shells of the retaining plates are arranged
at a 90° offset in relation to each other.
Storage/Over-wintering
Take the unit out of operation when temperatures below zero are to be
expected. Take the unit out of the water and remove pump (18).
Clean pump (18) under running water, store immersed in a water filled
container and frost protected. Do not immerse the power plug in the water!
Ensure that the storage place is inaccessible to children.
Store the floating body (5) in a dry and frost protected place.
Malfunction remedy
Malfunction | Cause | Remedy |
---|---|---|
Pump does not start | No mains voltage | Check mains voltage |
Clean, check supply lines
Pump does not deliver, insufficient delivered quantity| Retaining basket
clogged| Clean retaining basket
Skimmer housing too high in the water| Skimmer flap jammed or sluggish| Clean
skimmer flap bearing, ensure that skimmer flap operates freely
Insufficient cleaning effect| Skimmer flap jammed or sluggish| Clean skimmer
flap bearing, ensure that skimmer flap operates freely
Pump switches off after a short running perio| Excessively soiled water| Clean
pump
Water temperature too high| Note maximum water temperature of +35°C
Weight| Rated voltage| Power consumption| Max. flow rat| Connections| Cable
length
---|---|---|---|---|---
31 kg| AC 220-240 V, 50 Hz| 250 W| ≤250 l/min| G1½’| 10 m
| |
---|---|---
Dust tight. Submersible to 4 m depth| Do not dispose of together with
household waste!| Attention! Read the operating instructions
OASE GmbH
Tecklenburger Straße 161
48477 Hörstel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80
-9353
info@oase.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>