WARNING

Read these instructions before using the inflator. Failure to follow all the instructions listed below may result in damage to the product and/or cause serious injury to persons.

PRELIMINARY PRECAUTIONS

PRELIMINARY WARNINGS

  1. Comply with all instructions in this document.
  2. Keep these instructions.
  3. Always protect the power cable.
  4. Do not open the inflator. Refer all servicing to qualified service personnel authorised by Scoprega. Servicing is required when the device is damaged or not working in any way.
  5. Do not tamper with the product. Opening the inflator will void its warranty.
  6. Provide suitable ventilation.
  7. Avoid placing objects near the product during operation.
  8. Keep this product out of the reach of children.
  9. The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.

Warning

  • DO NOT POWER THE INFLATOR WITH A VOLTAGE HIGHER THAN THE RATED ONE.

GENERAL SAFETY RULES

  1. ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
    • Do not use in the presence of flammable liquids or gases.
  2. AVOID UNINTENTIONAL STARTING.
    • Do not start the inflator with the inlet in contact with dust or water.
  3. PAY ATTENTION.
    • Pay attention to what you are doing. Use common sense.
  4. CHECK THAT THERE ARE NO DAMAGED PARTS.
    • Before using the inflator, carefully check its outer sides and components.
  5. DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.
  6. DO NOT INHALE!
    • The compressed air coming from the inflator is not clean. Never inhale air from your inflator.
  7. WARNING:  RISK OF EXPLOSION.
    • Inflate the inflatable unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury.
  8. NEVER LEAVE THE DEVICE UNATTENDED.
    • Overinflation could result in serious injury and property damage.
  9. WARNING: RISK OF UNSAFE OPERATION.
    • Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflator or its accessories. Any modification to the product will void its warranty.
  10. NEVER CARRY THE INFLATOR BY THE FLEXIBLE HOSE OR POWER CABLE.
  11. DO NOT OBSTRUCT THE SUCTION PORT

INTRODUCTION

The GE 1800 EL is a device capable of inflating inflatable structures to a maximum pressure of 360 mbar. The inflator is equipped with thermal protection that interrupts inflating operations in the event of motor overheating. Normal operation will continue automatically after a break of 20/40 minutes.The inflator is supplied without hoses or fittings.

HOSES AND FITTINGS SUITABLE FOR THIS INFLATOR FOR CONNECTION TO THE MOST COMMON INFLATOR VALVES CAN BE PURCHASED FROM AUTHORISED SCOPREGA CENTRES.

DATI TECNICI

  1. Power supply: 210-240 Vac; 50 Hz
  2. MAX. power: 1800 W
  3. MAX. pressure: 360 mbar (5.2 psi)
  4. MAX. flow rate: 3400 l/min – 2700 l/m (0,1 bar)
  5. Dimensions: 330 x280 x h 350 mm
  6. Weight: 6,4 kg
  7. Operating temperature range: -10/40°C
  8. Protection degree: IP 66

HOW TO USE AND TO DEFLATE

HOW TO USE

  1. Connect the inflation hose to the inflation nozzle (Point 2 Fig.1) of the GE 1800 EL and the main valve of the inflatable structure.
  2. Connect the power cord to the socket. (Point 4 Fig.1).
  3. Press the main switch of the inflator to start inflation (Point 1 Fig.1).

Warning

  • CORRECTLY CONNECT THE HOSE TO THE INFLATOR AND THE INFLATABLE, ENSURING THAT THERE ARE NO LEAKS. CHOOSE THE APPROPRIATE GASKET FROM THOSE SUPPLIED.

TO DEFLATE

  1. Remove the cover on the deflation port by unscrewing the appropriate knobs (point 3 – fig 1)
  2. Connect the inflation hose to the IN input port of the inflator (point 3 – fig 1)
  3. Connect the other end of the hose to the valve of the inflatable.
  4. Connect the inflator to the power supply via the power cord (point 4 – fig 1)
  5. To start deflation press the ON/OFF switch (Point 1 Fig.1).
  6. Switch off the inflator once deflation is complete.

WARNING

  • THE INFLATOR DOES NOT SWITCH OFF AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE DESIRED PRESSURE HAS BEEN REACHED.
  • IN THE EVENT OF A POWER FAILURE DURING OPERATION, THE DEVICE IS NOT ABLE TO KEEP THE WORKING SETTINGS STORED AND CANNOT RESTART AUTOMATICALLY WHEN POWER IS RESTORED.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
The inflator does not start The power cable is not connected to the socket

Connect it correctly
The main GREEN switch is off| Press the switch
The power cable is damaged| Ask the SCOPREGA service to replace or repair the cable
The inflator is stopped| The power cable is not connected to the socket| Connect it correctly
The main switch is off| Press the switch
Over-temperature| Wait until the ARS motors cool down. The inflator will restart automatically.

ACCESSORY WARNING

  • The recommended accessories when using the inflator are the original SCOPREGA ones.
  • The use of any accessory not recommended for this inflator can be dangerous.

FUNCTIONAL DESCRIPTION

GE 1800 EL

SCOPREGA-GE-1800-EL-Electric-Inflator-fig-1

  1. ON/OFF SWITCH
  2. INFLATION PORT (IN)
  3. DEFLATION PORT (OUT)
  4. POWER CABLE