intertek LD-11-70303 Modern Bathroom Vanity Light Fixtures LED Instruction Manual

June 17, 2024
Intertek

LD-11-70303 Modern Bathroom Vanity Light Fixtures LED

Listing Constructional Data Report (CDR)

Reference and Address

Report Number| 23041036HKG-001| Original Issued:| 31-May-2023| Revised:| 10-Jul-2023
---|---|---|---|---|---
Standard(s)| Luminaires [UL 1598:2021 Ed.5+R:18Jun2021] Luminaires [CSA C22.2#250.0:2021 Ed.5+U1]
Applicant| ZHONGSHAN OKELI LIGHTING CO., LTD.| ** Manufacturer| ZHONGSHAN OKELI LIGHTING CO., LTD.
Address| **
2-5 Floor,Building A,No.36,ChangAn North Road,Henglan Town, Zhongshan City,Guangdong Province| Address| **** 2-5 Floor,Building A, No.36,ChangAn North Road,Henglan Town, Zhongshan City,Guangdong Province
Country| China| Country| China
Contact| Sen Rong Lin| Contact| Sen Rong Lin
Phone| 15019538593| Phone| 15019538593
FAX| NA| FAX| NA
Email| 2207738373@QQ.com| Email| 2207738373@QQ.com

Product Description

Product

|

LED Fixed luminaires

---|---
Brand name| NA
Description| The product covered by this report is a fixed luminaires intended for Damp location, mounted on outlet box and provided with supply Parallel cord or leads for field wiring supply connection.
Models| LD-11-70303, LD-12-52502, OKL-P-009, OK-9553-3T, SE-P0002-2+4+6
Model Similarity| All models are similar in mechanical and electrical construction. Difference between them are outlook, size, LED quantity and rating.
Model no.| Mounted Location| No. of LEDs| Dimension (mm)| Max. Weight (kg)
LD-11-70303| Ceiling| 1| ø128H137| 0.93
OK-9553-3T| Wall| 120| L600
W110H130| 1.9
LD-12-52502| Cord Pendant| 1| Ø62
H200| 0.95
OKL-P-009| Pendant| 45| Ø410H2000| 2.73
SE-P0002-2+4+6| Pendant| 444| Ø600
H2000| 1.98
Ratings| Model no.| Input voltage| Wattage|
LD-11-70303| 120V, 50/60Hz| 20W
OK-9553-3T| 120V,50/60Hz| 24W
LD-12-52502| 120V, 50/60Hz| 20W
OKL-P-009| 120V, 50/60Hz| 40W
SE-P0002-2+4+6| 120V, 50/60Hz| 45W
Other Ratings| NA

This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Product Photographs

Photo 1 – External View of model LD-11-70303  intertek LD-11-70303 Modern
Bathroom Vanity Light Fixtures LED - Photo 1Photo 2 – Rear view of model LD-11-70303 intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
2Photo 3 – Internal view of model LD-11-70303 intertek LD-11-70303 Modern Bathroom Vanity Light
Fixtures LED - Photo 3Photo 4 – Internal view of model LD-11-70303 intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
4Photo 5 – External View of model OK-9553-3T intertek LD-11-70303 Modern Bathroom Vanity Light
Fixtures LED - Photo 5Photo 5a – Top View of model OK-9553-3Tintertek LD-11-70303
Modern Bathroom Vanity Light Fixtures LED - Photo 6Photo 6 – Internal view of model OK-9553-3T intertek LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
7Photo 7 – Internal view of model OK-9553-3T intertek LD-11-70303 Modern Bathroom Vanity Light
Fixtures LED - Photo 8Photo 8 – External View of model LD-12-52502 intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
9Photo 9 – Internal view of model LD-12-52502 intertek LD-11-70303 Modern Bathroom Vanity Light
Fixtures LED - Photo 10Photo 10 – Internal view of model LD-12-52502intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
11Photo 11 – External View of model OKL-P-009 intertek LD-11-70303 Modern Bathroom Vanity Light
Fixtures LED - Photo 12Photo 12 – Internal view of model OKL-P-009 intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
13Photo 13 – Internal view of model OKL-P-009intertek LD-11-70303 Modern Bathroom Vanity Light
Fixtures LED - Photo 14Photo 14 – Internal view of model OKL-P-009intertek LD-11-70303
Modern Bathroom Vanity Light Fixtures LED - Photo 15Photo 15 – Internal view of model OKL-P-009 intertek LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
16Photo 16 – External View of model SE-P0002-2+4+6 intertek LD-11-70303 Modern Bathroom Vanity
Light Fixtures LED - Photo 17Photo 17- Internal view of model SE-P0002-2+4+6intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
18Photo 18- Internal view of model SE-P0002-2+4+6 intertek LD-11-70303 Modern Bathroom Vanity
Light Fixtures LED - Photo 19Photo19 – Mounting package for model LD-11-70303,OK-9553-3T,LD-12-52502,OKL-P-009,SE-P0002-2+4+6. intertek
LD-11-70303 Modern Bathroom Vanity Light Fixtures LED - Photo
20

Critical Components

Photo #| Item no.1| Reflective cup holder| Manufacturer/ trademark2| Type / model2| Technical data and securement means| Mark(s) of conformity 3
---|---|---|---|---|---|---
1| 1| Canopy 1| Various| Various| Painting Aluminum, 0.66mm thick min. Opening 1.1mm thick min| NR
6,8, 11, 17| 1a| Canopy 2| Various| Various| Painting steel, 0.66mm thick min.| NR
2,6, 9, 13,
17| 2| Mounting Bracket| Various| Various| Galvanized Sheet steel, measured min., thickness 1.0mm, Provide with a green-headed grounding screw for bonding. Height of two raised areas of grounding terminal: 1mm min.| NR
2,6, 9,
13, 17| 2a|

Fiberglass sleeving(Not shown)

| Various| Various| Silicone coated fiberglass sleeving. 0.25mm thick min., cover whole input wires of LED driver/flexible cord through mounting bracket openings.| UR
3| 3| LED driver 1| HONGKONG YEONGDEOK PHOTOELECTRI C LTD| YD25D- 050040SCR| Class 2 drive, Damp. Dimmable. Input:120Vac 50/60Hz, 0.18A Output: 24-40Vdc, 0.5A, Tc=75°C.
Input wire:Color black, white, AWM; 18AWG min, 300V
min,105°C min, VW-1. Extend at least 150mm into outlet box.
Output wire:AWM; 22AWG min, 300V,105°C min, VW-1.| cURus
6| 3a| LED driver 2| Foshan Nanhai Pingyi Electronic Co.,Ltd.| PYB025C0800L XD1P| Class 2, Damp. Dimmable. Input:120-277Vac 50/60Hz, 0.35A. Output: 24-31Vdc, 0.8A, 25W max. Tc=85°C.
Input wire:Color black, white, AWM; 18AWG min, 300V
min,105°C min, VW-1.Extend at least 150mm into outlet box.
Output wire:AWM; 22AWG min, 300V,105°C min, VW-1.| cETLus Recognize d
9| 3b| LED driver 3|

HONGKONG YEONGDEOK PHOTOELECTRI C LTD

| YD-VU13-18WB| LVLE drive, Damp. Dimmable. Input:120Vac 50/60Hz, Output: 24-40Vdc, 0.5A, Tc=75°C.| cURus
Photo #| Item no.1| Reflective cup holder| Manufacturer/ trademark2| Type / model2| Technical data and securement means| Mark(s) of
conformity3
---|---|---|---|---|---|---
13| 3c| LED driver 4| HONGKONG YEONGDEOK PHOTOELECTRI C LTD| YD45- 120040SCR| Class 2 drive, Damp. Dimmable. Input:120Vac 50/60Hz, 0.4A Output: 24-40Vdc,1.2A, Tc=80°C.
Input wire: Color black, white, AWM; 18AWG min, 300V
min,105°C min, VW-1.Extend at least 150mm into outlet box.
Output wire:AWM; 22AWG min, 300V,105°C min, VW-1.| cURus
17| 3d|

LED driver 5

| HONGKONG YEONGDEOK PHOTOELECTRI C LTD|

YD40-1050

| LVLE drive, Damp. Dimmable. Input:100-277Vac 50/60Hz, Output: 22-38Vdc, 1.05Amax. Ta=45°C,Tc=90°C. Provided input and output terminals, suitable for

14-24AWM wiring.| cETLus Recognize d

3,6, 9, 13, 17| 4| Grounding Wire| Various| Various| Bare copper wire, 18AWG. Secured to Canopy by nut with lug terminal. Extend at least 150mm

into outlet box.

| NR
Various| Various| Color green with a yellow stripe. AWM. 18AWG, rated min. 300V, 105°C, VW-1. At least 150mm long in wire compartment.| UR
4,7, 10, 15| 5| LED PCB 1| Various| Various| Single layer metal base printed wiring boards.V-0, min 130°C, 1.1mm thick min., comply with UL796.| UR
18| 5a| LED PCB 2| Various| Various| Single layer flexible materials interconnect constructions. V-0, min. 110°C. Min. CTI:3, 1.0mm
thick min., provided with smooth opening/edge for wire entry. Secured by glue.| UR
4,

10

| 6| LED 1| Various| Various| COB,VF: 36.2-42V, IF: max.1050mA, CCT: 2700-6500K| NR
7, 15, 18| 6a| LED 2| Various| Various| SMD VF: 2.8-3.4V, IF: 60-150mA, CCT: 2600-6500K| NR
4, 10| 7| LED Fixed support| Various| Various| PC, V-0, min.0.8mm thick, 105°C, secured to Metal enclosure by screws.| cURus
4| 8| Mesh sheet| Various| Various| Aluminum, 0.1mm thick min., secured by reflective cup holder.| NR
4| 9| Lens frame| Various| Various| PMMA, V-0, min.0.8mm thick min , 105°C min , secured to LED Fixed support by slot.| cURus
4,7, 10, 15| 10| Lens| Various| Various| PMMA, V-0, min.1.0mm thick min, 110°C min, secured by Lens frame.| cURus
4,7| 11| Reflective cup holder| Various| Various| PC,V-0, min 80°C. 0.8mm thick min., secured by mechanical fitting.| cURus
---|---|---|---|---|---|---
6,7, 18| 12| Fiberglass sleeving| Various| Various| Silicone coated fiberglass sleeving. 0.25mm thick min., through metal openings.| UR
9| 13| Flexible cord| Various| SVT| Color black, white and green for grounding connection, 3 x Min. 18AWG, 300V, 105°C, VW-1.
Made a knot in both side of cord as Strain relief. Extend at least 150mm into outlet box.|

cULus

9| 14| Bushing| Various| Various| Plastic, non-rubber type. 1.0mm thick min. Physically fitted to each end of metal openings to protect internal wires.| NR
5a, 12, 16| 15| Metal enclosure1| Various| Various| Painting steel. Minimum 0.66mm thick.| NR
8, 10| 15a| Metal enclosure2| Various| Various| Painting Aluminum. Minimum 0.66mm thick. 1.1mm thick min at opening for wire entry.| NR
7, 11, 16| 16| Diffuser| Various| Various| PS, rated HB, 80°C, min. 1.0mm thick.
Secured by screws for models OK-9553-3T.
Secured by mechanical fitting for models OKL-P-009, SE-P0002- 2+4+6.| cURus
11| 17| Diffuser fix shelf| Various| Various| Painted steel, min. 0.51mm thick, secured by screws.| cURus
11| 18| External cord 1| Various| 20242| 2x24AWG min., 300V, 105°C min., provided with extruded FEP jacket, The wire is protected by a thin layer of plastic on the wire entry, in class 2 circuit.| UR
16| 18a| External cord 2| Various| 2464| Jacketed type AWM wire, 2x24AWG, 300V, 80ºC min, in class 2 circuit.| UR
11, 16| 19| Suspending metal Wires| Various| Various| Steel wires. Dia.1.2mm min., Fixed between the canopy and the lamp body. Shorter than External cord for suspending the luminaire. Two provided for model OKL-P- 009.  Six provided for model SE-P0002- 2+4+6:| NR
---|---|---|---|---|---|---
12, 16| 20| Strain relief| Various| Various| Steel, Ø12mm x 12mm, measured 3.4mm thick, thick min., with smooth opening for cord entry.| NR
12, 16| 21| Fixed insulated screw| JIANGYIN JIHUA NEW MATERIAL CO LTD| PCXh66(aa)| PC. Ø3.8mm x 4mm., rated V-0, 80°C. min 0.8mm thick. Used for fixing wires| cURus
6,1 3,1 5| 22| Closed-end connector(not shown)| Various| Various| Rated Min. 300V, min.105°C. Suitable for conductors(10- 22AWG), Covered by Heat Shrinkable Tube| cULus
6, 13, 18| 23| Heat Shrinkable Tube| Various| Various| 600V min. 125°C. VW-1. Covered closed end connector and covered between wire connection and flexible LED PCB.| cURus
13, 17| 24| Strain relief device| JIANGYIN JIHUA NEW MATERIAL CO LTD|

PCXh66(aa)

| 8-shaped. PC. V-0, 80°C min, 0.8 mm thickness min. Secured the each flexible supply cord.| cURus
7, 10, 15| 25| Internal wires| Various| Various| 24AWG min, 300V min,105°C min., in secondary circuit.| UR
18| 26| Glue| Various| Various| Silicone, V-1, 105°C. Min 1.5mm thick. Secured LED PCB and wire soldering connection.| cURus
8| 27| Cord clips| Various| Various| PC, V-0, min.1.0mm thick, 105°C, secured by bolt and nut.| cURus
17| 28| Input wires| Various| Various| 18AWG min, 300V min,105°C min, color black and white, extended at least 150mm into outlet box for field wiring connection.|

cURus

14| 29| On-board terminal| Various| Various| Push-in splicing type, 600V,105℃, for use with 12-26 AWG solid copper only in secondary circuit.| cURus
19| 30| Mounting screws| Various| Various| Two provided, Machine screws, Ø3.9mm, min. 20mm long min.| NR
19|

31

| Twist on connectors|

Various

|

Various

| Three provided, Rated 300V  min,105°C min.Suitable for 10-22 AWG wire.| UL,CSA
1,5, 8, 11, 16| 32| Marking Label (Not shown)| Various| Various| Rated 80°C on Steel surface , complied with UL969.| cURus

NOTES:

  1. Not all item numbers are indicated (called out) in the photos, as their location is obvious.
  2. “Various“ means any type, from any manufacturer that complies with the “Technical data and securement means” and meets the “Mark(s) of conformity” can be used.
  3. Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. “NR” – indicates Unlisted and only visual examination is necessary. “See 5.0” indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.

Critical Unlisted CEC Components

No Unlisted CEC components are used in this report.

Critical Features

Recognized Component – A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability.
Listed Component – A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings.
Unlisted Component – A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition.
Critical Features/Components – An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product’s conformance to applicable requirements of the product standard.
Construction Details – For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply.

  1. Spacing – In primary circuits, 3.2 mm minimum spacing are maintained through air and 6.4mm over surfaces of insulating material between current-carrying parts of opposite polarity and between such currentcarrying parts and dead-metal parts or low
    voltage isolated circuits.

  2. Mechanical Assembly – Components such as switches, fuseholders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component.

  3. Corrosion Protection – All ferrous metal parts are protected against corrosion by painting, plating or the equivalent.

  4. Accessibility of Live Parts – All uninsulated live parts in primary circuitry are housed within a metal enclosure constructed with no openings other than those specifically described in Sections 4 and 5.

  5. Grounding – All exposed dead-metal parts and all dead-metal parts within the enclosure that are exposed are connected to the grounding blade of the Track adaptor or the equipment grounding terminal.

  6. Polarized Connection – This product is provided with a polarized power supply connection. All single pole switches and fuses are connected only to the ungrounded supply circuit conductor.

  7. Internal Wiring – Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is  rotected against abrasion or damage by plastic bushings or grommets. All wiring refer to 4.0.

  8. Markings – The product is marked on a labeling system as described in item no. 32 of Section 4.0 as follows: (Refer to iIlustration 1 for format designation of marking)
    Applicant Name or brand name (S16-L2)
    Model number (S16-L2)
    Date code of at least the month and year of manufacture (S16-L2)
    Input rating in volts(V), hertz(HZ), and watts(W) (S24-L3)
    For grounding conductor and terminal: “G”, “GR, “GRD”, “GND”, “GRND”, “GROUND”(S16-L3) or grounding symbol(see Illustration 2)

  9. Cautionary Markings – The following are required
    “SUITABLE FOR DAMP LOCATIONS” & “CONVIENT AUX EMPLACEMENTS HUMIDES” (S16-L2, Verbatim)
    For wall mount units : models OK-9553-3T
    “WALL MOUNT ONLY” & “INSTALLATION MURALE SEULEMENT”(S24-L2, Verbatim)
    “MOUNTING ORIENTATION – (Such as this end up)” & “SENS DE MONTAGE [par example, cette extrémité vers le haut]” (S24-L2)

  10. Installation, Operating and Safety Instructions – Instructions for installation and use of this product are provided by the manufacturer.

The instruction manual shall contained the following information: (S16-L5)

  1. INSTALLATION OR ASSEMBLY INSTRUCTIONS
    a. Wiring instructions that specify the proper method of connecting the grounding means and maintaining polarity shall be included with the luminaire in a manner that will require the installer to handle the instructions during installation.
    b. Specification of mounting hardware shall be included in the instruction sheet.
    d. Other warnings that will not lead to misuse.

  2. The luminiaire should be installed by a licensed electrician.

  3. Show the method of strain relief that shall be applied in the field, such as a knot in the cord.(For cordpendant luminaire)

Illustrations

Illustration 1 – Format Designation of Markings and Instructions
The table of the format minimum size designation (S__) for marking height and typeface is at below:

Size Designation| Letter Height| Font Size| Font typeface, upper case
---|---|---|---
( mm )| ( in )| (points)
S16| 1.6| 0.062| 6| Univers bold, Arial bold, Helvetica bold, Zurich BT bold
S24| 2.4| 0.094| 10| Univers bold, Arial bold, Helvetica bold, Zurich BT bold
S32| 3.2| 0.125| 12| Not specified
S48| 4.8| 0.188| 19| Univers bold, Arial bold, Helvetica bold, Zurich BT Bold

The table of the format location designation (L__) for marking is at below:

Location| Description| Label exposed to a| Label exposed to a
---|---|---|---
L1| Visible during relamping, after installation| Type P| Type P
L2| Visible during installation| Type N| Type P
L3| Visible during installation and inspection of wire connections, located near the supply| Type N| Type P
L4| On the smallest unit package or carton| Type T| Type T
L5| On an instruction sheet or tag, or manufacturers website| Type T| Type T
L6| Visible during component replacement| Type P| Type P

Type N designates a non-permanent label or nameplate that is intended to remain in place only for the purpose of Type T designates a temporary label, instruction sheet, or tag that is not required after installation. It provides installation instructions, and information not required after installation. It is made of printed matter with or without adhesive and/or attachment, and is intended to be included with, or attached to, the product, or designates a publicly accessible website.
Type P designates a permanent label or nameplate that is intended to remain in the applied position for the
Illustration 2 – Grounding symbol

Test Summary

Evaluation Period 18-Apr-2023 to 30-May-2023 Project No. HK23041036
Sample Rec. Date 18-Apr-2023 Condition Prototype

230418104001~2 30418104004.
230429104002
Test Location| LCTECH Guangdong Testing Services Co., Ltd. (Address: LCTECH Plaza, Guangyuan Rd, Xiaolan, Zhongshan, Guangdong, China.)
Test Procedure| Testing Lab
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
The following tests were performed:
Test Description| UL 1598:2021Ed.5+R:18Jun202  1 and CSA C22.2#250.0:2021 Ed.5+U1 Clause
Normal Temperature Test – Surface ceiling luminaires| 15.2
Normal Temperature Test – Surface wall luminaires| 15.3
Mold stress relief| 17.4
Loading| 17.15
Strain relief| 17.21
Ground-screw assembly strength| 17.39
Dielectric voltage-withstand| 18.1
Bonding circuit impedance| 18.2
Articulate probe| 18.4
Test Description| UL 8750:2015 Ed.2+R:7Dec20 22 Clause| CSA C22.2#250.13:202 0 Ed.4+U1 Clause
Input Test| 8.2| 9.2
Temperature test| 8.3| 9.3
Dielectric Voltage-withstand| 8.6| 9.4
Humidity Exposure| 8.14| 9.12.1

8.1 Signatures

A representative sample of the product covered by this report has been evaluated and found to comply with the applicable requirements of the standards indicated in Section 1.0.

Completed by: Alexis Lee Reviewed by: Terry Lau
Title: Lead Engineer Title: Supervisor
Signature: Signature on file Signature: Signature on file

Correlation Page For Multiple Listings

The following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.

BASIC LISTEE ZHONGSHAN OKELI LIGHTING CO., LTD.
Address 2-5 Floor,Building A,No.36,ChangAn North Road,Henglan Town, Zhongshan

City,Guangdong Province
Country| China
Product| LED Fixed luminaires
MULTIPLE LISTEE 1| None
---|---
Address|
Country|
Brand Name|
ASSOCIATED MANUFACTURER|
Address|
Country|
MULTIPLE LISTEE 1 MODELS| BASIC LISTEE MODELS
|
| |
MULTIPLE LISTEE 2| None
---|---
Address|
Country|
Brand Name|
ASSOCIATED MANUFACTURER|
Address|
Country|
MULTIPLE LISTEE 2 MODELS| BASIC LISTEE MODELS
|
| |
MULTIPLE LISTEE 3| None
---|---
Address|
Country|
Brand Name|
ASSOCIATED MANUFA CTURER|
Address|
Country|
MULTIPLE LISTEE 3 MODELS| BASIC LISTEE MODELS

General Information

The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.
COMPONENTS
Components used shall be those itemized in this Intertek report covering the product, including any amendments and/or revisions.
LISTING MARK
The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.
The mark must include the following four items:

  1. applicable country identifiers “US” and/or “C” or “US”, “C” and “EU”
  2. the word “Listed” or “Classified” or “Recognized Component” (whichever is appropriate)
  3.  a control number issued by Intertek
  4. a product descriptor that identifies the standards used for certification. Example:

For US standards, the words, “Conforms to” shall appear with the standard number along with the word, “Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”
For Canadian standards, the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”
Can be used together when both standards are used.
If all standards on the ATM have the same standard title, the shared title or its abbreviation may be used in place of the examples above. Example: “Medical Electrical Equipment” or “MEE”; “Information Technology Equipment” or “ITE”; “Audio/Video Information And Communication Technology Equipment” or “A/V ICTE”.
Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use.
The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility.
MANUFACTURING AND PRODUCTION TESTS
Manufacturing and Production Tests shall be performed as required in this Report.
FOLLOW-UP SERVICE
Periodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following:

  1.  Conformance of the manufactured product to the descriptions in this Report.
  2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement.
  3. Manufacturing changes.
  4. Performance of specified Manufacturing and Production Tests.

In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions:

  1. Correct the non-conformance.
  2. Remove the ETL Mark from non-conforming product.
  3. Contact the issuing product safety evaluation center for instructions.

10.1 Evaluation of Unlisted Components
The Applicant will be notified, in writing, via the applicable contact methods, as defined in Section 1.0, when these components must be selected and sent to Component Evaluation Center (CEC) for reevaluation. Due to particular testing requirements, some components may be requested to be shipped to specific labs. Thus, specific shipment destination(s) for each sample will be provided in the written notification.
Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.

Managing CEC Location:
Intertek Testing Services Hong Kong Limited
ETL Component Evaluation Center
Unit H, 3/F., Garment Centre, 576 Castle Peak Road
Kowloon, Hong Kong
Attn: Sample Room
Sample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component shipment.

Manufacturing and Production Tests

The manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:
Required Tests
Dielectric Voltage Withstand Test
Grounding Continuity Test
Strain Relief Test
Ground Screw Torque
Accessible Edges Test

11.1 Dielectric Voltage Withstand Test
Method
One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test.
The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contactors, relays, etc., should be closed so that all primary circuits are energized by the test potential.
If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.
The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required.
Test Equipment
The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown.
The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA.
If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either:
1 – a voltmeter in the primary circuit;
2 – a selector switch marked to indicate the test potential; or
3 – a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output.
In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration.

Test Record
Test records shall be retained for a period of at least six months, and include test quantity, test dates, catalogue or model numbers, test results, and disposition of any non-complying products.

Product All products covered by this Report.
Products
Requiring Dielectric Voltage Withstand Test:
Test Voltage …………………1200V
Test Time ………………..1 s

11.2 Grounding Continuity Test
Method
All luminaires shall be subjected to test at least once per quarter per design. The test shall be performed on luminaires with non-current-carrying metal parts that can become energized and are accessible during user maintenance or snap-in lampholders with integral grounding means.
An ac or dc power supply of approximately 12V providing a current of 30A through the bonding means being evaluated. Alternatively, it may be determined by an ohmmeter or similar indicating instrument. The measured or calculated resistance shall not exceed 0.10 ohm.
Test Record
Test records shall be retained for a period of at least six months, and include test quantity, test dates, catalogue or model numbers, test results, and disposition of any non-complying products.
Product All products covered by this Report.
Products
Requiring Grounding Continuity Test:
Resistance……………. Not exceed 0.1 ohm
11.3 Strain Relief Test
Method
One sample of each luminaire design with a power supply cord shall be tested at least once per quarter to determine compliance with the strain-relief test for flexible cords.
A pull force of 156 N (35 lb) shall be applied for 1 min to the flexible cord in a direction perpendicular to the plane of the entrance into the luminaire.
Test results shall be acceptable if there is no:
(a) movement of the flexible cord of more than 1.6 mm (0.063 in); and
(b) breaking of the conductor or loosening of the wiring connections inside the enclosure of the luminaire.
Test Record
Test records shall be retained for a period of at least six months, and include test quantity, test dates, catalogue or model numbers, test results, and disposition of any non-complying products.

Products Requiring Strain Relief Test:
All products (pendant units) covered by this Report.

11.4 Ground Screw Torque Test
Method
One sample of each luminaire design provided with a screw for securing the branch circuit equipment grounding conductor shall be tested at least once per quarter to determine compliance with the ground-screw assembly strength test.
A 12 AWG (3.3 mm2) solid-copper, insulated conductor shall be stripped to a length of 2.5 cm (1 inch) minimum.
The wire shall be wrapped around the screw under the screw head so that it makes a minimum 180° turn. The conductor shall be seated to follow any wire guides or dimples provided to align the conductor with the mating surface. The ground screw shall be tightened with a calibrated torque screwdriver to 1.6 Nm (14 lb-in).
When tested as described in this section, there shall not be:
a) damage to the head of the ground screw which would prevent the 1.6 Nm (14 lb-in) of tightening torque to be achieved; or
b) stripping of the ground screw assembly.
Test Record
Test records shall be retained for a period of at least six months, and include test quantity, test dates, catalogue or model numbers, test results, and disposition of any non-complying products.

Products Requiring Ground Screw Torque Test:
All products covered by this Report.
11.5 Accessible Edges Test
Method
When considering sharp edges and points, all stages of the installation process shall be considered.
One sample of each luminaire style that contains an accessible edge that does not comply with below(a), (b), or (c), shall be tested twice annually.
An enclosure, frame, or similar device shall not have accessible edges that are sharp or pointed such that they constitute a risk of injury to persons during normal installation, maintenance, and use, unless:
a) accessible edges are protected by guards or the use of handles to minimize access to sharp edges during installation or maintenance;
b) an accessible edge or portion of an accessible edge shall be required to be sharp in order to perform a working function; or
c) it is possible to avoid the hazard through proper procedures; then signs, labels, or the manufacturer’s instructions shall describe the procedure to avoid the hazard during installation, maintenance, and use.
Whenever referee measurements are necessary to determine that a part as mentioned in above is not sufficiently sharp to constitute a risk of injury to persons, the method described in UL 1439, Tests for Sharpness of Edges on Equipment, shall apply.
Test Record
Test records shall be retained for a period of at least six months, and include test quantity, test dates, catalogue or model numbers, test results, and disposition of any non-complying products.
Products Requiring Accessible Edges Test:
All products covered by this Report.

Revision Summary

The following changes are in compliance with the declaration of Section 8.1:

Date/ Project Handler/ Section Item Description of Change
Proj # Site ID Reviewer
10-Jul-2023 Alexis Lee 4 2 Corrected mounting bracket thickness from 1.5mm

to 1.0mm.
HK23041036HKG| Terry Lau| 2a| Added item
| | | |
| | | |
| | | |
| | | |

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals