Energizer PPS2000 LiFePO4 Battery Portable Power Station User Manual

June 17, 2024
Energizer

USER MANUAL
PPS2000W01 Power StationEnergizer PPS2000 LiFePO4 Battery Portable
Power Station -

PPS2000W01 Portable Power Station
No more worries about being outdoors or having a power outage. With 2150Wh capacity and up to 21 DOW AC output, PPS2000WO1 always keeps you charged at any on-the-go moment. Featuring 100W USB-C PD, 2100W AC power outlet and USB-A charging  ports, PPS2000W01 provides 17 outputs that can charge multiple devices or appliances simultaneously and efficiently. With premium battery and PowerSafe management. Energizer Portable Power Station PPS2000W01 is your most reliable and safe power  solution anytime, anywhere.

ATTENTION
A.The specifications and the pictures in this manual are for reference only.
B.The product is perfect for off-grid power needs or backup power for emergency situations.
C.Actual AC outlet and AC adapter will be different depending on the locations of the customer.
D.To maximize the battery life, please fully charge the product before using it for the first time.

Get To Know Your Product

  1. Quick Guide
    Energizer PPS2000 LiFePO4 Battery Portable Power Station -
parts
01 Aviation Output 05 Aviation Input 09 USB A 18W
02 Power Button 06 AC Adapter Input 10 12V DC Charging Port
03 LCD Touch Screen 07 Wireless Charging 11 DC 5521 Output
04 AC Output6 08 USB-A Output 12 Output PD100w

Charging Your Product

ATTENTION
If the ambient temperature is too high or the battery temperature is higher than 60 ‘C due to continuous high-power discharge, the product cannot be charged. When the battery temperature is less than 55C, the charging function will automatically resume.
If the battery is not used for a long time, the battery should be stored in a dry and ventilateroom with an ambient temperature of 0-35 C for more than 3 months, and the battery should be charged to 50%-80%.

LCD Battery Display
As you use your product, segments will disappear from the display, indicating the remainincharge. When charging your product you will notice a battery segment blinking at a 1 second interval status. Once your product is fully charged, all battery segments will  be lit and remain solid.

Charge Through Solar Panel

Energizer PPS2000 LiFePO4 Battery Portable Power Station - connecting
cable

A.Place your solar panel where it will get as much strong direct sunlight as possible.
B.Connect the output port of the solar panel with the input port of the product to start charging. You will know the product is being charged when the LCD displays the charging percentages on the screen. The product is fully charged when displays 100%.

Notes:
The actual charging efficiency can vary widely depending on weather, ambient temperature, sunlight, and the angle that the solar panel faces to the direct sunlight and other factors. The maximum output voltage of the solar panel should not exceed 145V.
In order to ensure solar charging efficiency, it is recommended to use solar panels with an open circuit voltage of 10-145V. The maximum current can reach 15A.

Charge Through AC Adapter

Energizer PPS2000 LiFePO4 Battery Portable Power Station - Ac
Adapter

Plug the adapter (optional) into it’s DC input port and you will see the state of charge displayed in the screen.

Notes:
A.The product is fully charged when battery displays 100% capacity on the screen. After the product is fully charged, please unplug the AC wall charger as soon as possible.
B. Usually, it takes about 5 hours to fully charge the machine using the original power adapter.

Charge Through Your Car

Energizer PPS2000 LiFePO4 Battery Portable Power Station -
charge

A. Plug the car charger into the 12 V DC Charging Port of your car, and then plug into the DC input port of the machine.
B. The original car charger features a 1 OA protector tube to protect your car.
C. The product is fully charged when the battery displays 100% capacity on the screen.

Charge Through Lead-Acid Battery

Energizer PPS2000 LiFePO4 Battery Portable Power Station -
battery

A. Take proper precautions whenever handling a Lead-acid battery. Wear protective eye glasses angloves to protect yourself from any acid that may leak from the battery.
B. Connect the charger’s red positive(+) cable clamp to the positive (+) post.
C. Secure the black negative(-) cable clamp to the negative (-) post.
D. Plug the charger into the Aviation input socket.

 Notes:
To avoid car battery power loss, you should charge this product through your 12V DC Charging Port only when your car engine is started.This function is for 12V cars ONLY.

Protection mode (DC input)
A. Due to the different models of cars, it may not be fully charged.
B. Under-voltage protection: The power generator can’t be charged if the voltage of your car is too low.

AC+DC Dual Charging
Plug your AC and DC charger to speed up charging.

Energizer PPS2000 LiFePO4 Battery Portable Power Station - dual
charging

Using Your Product

Buttons & Switches Energizer PPS2000 LiFePO4 Battery Portable Power
Station - switches

a. PV/ Other Charging Display
b. BMS Info
c. Date/ Time
d. DC Load Info| e. DC ON/ OFF Switch
I. AC ON/ OFF Switch
g. Adapter Charging Display
h. AC Load Info
---|---

A. Press the power button to turn the machine on. Press again to turn the machine off.
B. Tap the switch on the screen in the homepage to turn your output mode ON/ OFF.

USB Output Function

Energizer PPS2000 LiFePO4 Battery Portable Power Station - usb
output

When two USB-A 5V/3A ports are used simultaneously, the two ports can only output 5V/3A total, so it cannot enter the fast charging mode.

DC Outputs

Energizer PPS2000 LiFePO4 Battery Portable Power Station - dc
outputs

A. The 12V DC Charging Port and The DC5521 (5.5mm in diameter) 11.2-14.6V ports offer max 1 0A output current and automatically distributes max current according to the external connected devices to ensure shortest charging time.
B. The DC5521 port can be connected with a 12V DC Charging Port (power requires no more than 120 W).

Notes:
If the output DC and USB of the product are greater than 32A at the same time, the buzzer alarms after the product runs for three minutes. The LCD error code is E11. If the alarm lasts for 30 seconds and is not cleared, the product will forcibly shut down the DC  output to reduce the total DC output current and ensure the safety of the product.
In vehicle charging mode, when the voltage of the charging port is lower than 11.2V, the charging function will stop charging to avoid over-discharge of vehicle power.

Protection mode (DC outputs)
Short circuit protection: when short-circuit occurs to the external devices, the machine starts beeping and stops charging.

Product Specifications

Battery

Battery LiFeP04 Battery
Battery Capacity 2150Wh, 51.2VDC, 42000mah
Lifecydes 3000 Cydes to 80% Capacity
Battery Maintenance Charge Every 3–6 Months

Port (Output)

USB-A2 5V DC, 3A; 1 SW total
0C3.0 0SB2 5V DC, 3A; 9V DC 2A; 12V DC, 1.5A
PD Type-C Port 5/9/12/15V DC, 3A; 20V DC, 5A
DC 55212 12V, 10A total

Car Charging
RV/ Aviations Sockets| 12V, 30A
Wireless Charging2| 5/7.5/10V DC, 15W2
AC Output6| 100V AC, 2000W total; 110V AC, 2100W total

Charging (Input)

Solar Charging 10-145V DC, 15A, 900W Max
Car Charging 11-28.8V, 8.2A

Battery Charging

General

Weight About 66.1 lbs/ 30 kg
Dimensions 17.311.6815.3 in
Discharge Temp -4-104F (-20-40C)
Charge Temp 32-104F (0-40C)

Cold Weather Usage
Cold temperatures can affect the product’s battery capacity due to chemical characteristics of the battery. If you’ll be living off grid in sub-zero conditions, it is recommended to keep your product in an insulated cooler, and connected to a power source (12V  car/AC adapter/solar panel). The natural heat generated by the product contained in an insulated cooler will keep battery capacity at its highest level.
Disposal And Recycle
This product should not be disposed along with household waste. Please dispose or recycle this product and the battery inside according to the local rules and regulations  Battery Information
This product has an internal, non-removable, LiFePO4 Rechargable battery. Do not attempt to remove the battery, as you may damage the device.

Error Code

Code Causes Solutions
1 PV Over Voltage Please check if the open circuit voltage of solar panels

exceeds the input voltage standard of the power station.
§| DC Output Short Circuit| Please disconnect the appliances on DC output ports.
5| Adapter Over Voltage| Please check that the adapter output voltage meets the specification. Clear the alarm history or restart the unit
6| Adapter Low Voltage| Please check that the adapter output voltage meets the specification. Clear the alarm history or restart the unit.
7| Adapter Relay Error| Clear the alarm history or restart the unit,
8| Adapter Over Current| Please check that the adapter output voltage meets the specification. Clear the alarm history or restart the unit.
10| USB/TYPE-C Over Current| Please disconnect the appliances on USB ports. Clear the alarm history or restart the unit.
11| 12V/10A Over Current| Please disconnect the appliances on DC 12V/10A ports. Clear the alarm history or restart the unit.
12| 12V/30A Over Current| Please disconnect the appliances on DC 12V/30A ports. Clear the alarm history or restart the unit.
14| DC Start Failure| Clear the alarm history or restart the unit.
15| DC Output Relay Error| Clear the alarm history or restart the unit.
16| Bus Start Failure| Clear the alarm history or restart the unit.
17| Inverter Start Failure| Turn on the AC after rebooting, please contact the dealer if the error still exists.
18| Bus Low Voltage| Turn on the AC after rebooting, please contact the dealer if the error still exists.
19| Bus High Voltage| Turn on the AC after rebooting, please contact the dealer if the error still exists.
20| Inverter Low Voltage| Please check if the output of the load meets the specifications of the unit. Turn on the AC after rebooting, please contact the dealer if the error still exists.
21| Inverter High Voltage
22| Inverter Low Frequency| Please check if the output of the load meets the specifications of the unit. Turn on the AC after rebooting, please contact the dealer if the error still exists.
23| Inverter High Frequency
25| Battery High Voltage| Please contact the dealer if the error still exists after rebooting the unit.
26| Battery Low Voltage| Please contact the dealer if the error still exists after rebooting the unit.
---|---|---
27| Battery Unconnected
28| Fan Error| Clean or replace the fan to ensure proper ventilation. Please contact the dealer if the error still exists after rebooting the unit.
29| NTC Error| Leave the unit at the recommended temperature few hours to recover. Please contact the dea kr if the error still exists
after rebooting the unit.
30| Calibration Error| Please contact the dealer If the error still exists after rebooting the unit
31| Inverter Over Load| Please disconnect the load to make sure the output power of the loads meet the limit of the unit. Click to clear the alarm history.
32| Inverter Short Circuit| Please disconnect the load to make sure the load has been connected properly. Click to clear the alarm history.
33| DSP Communication Error| Please contact the dealer if the error still exists after rebooting the unit.
34| BMS Communication Error| Please contact the dealer if the error still exists after rebooting the unit.
35| EEPROM Read_write Error| Please contact the dealer If the error still exists after rebooting the unit.
36| Parameters of Control Module Error| Reset the configurations on Settings’. Please contact the dealer if the power station have not been recovered after rebooting.
41| BMS Temperature Error| Please store the power station at the recommended temperature and leave it until the temperature inside is back to the normal standard.
42| BMS Over Voltage| Please contact the dealer if the error still exists after rebooting the unit.
43| BMS Low Voltage| Please contact the dealer if the error still exists after rebooting the unit.
44| BMS Over Current| Please contact the dealer if the error still exists after rebooting the unit.
45| BMS Pre-charge Failure| Please contact the dealer if the error still exists after rebooting the unit.
46| BMS Output Short Circuit| Please contact the dealer If the error still exists after rebooting the unit.
51| AC Output Locked| Disconnect the load to make sure the output power of loads limit Please
the meet the of the unit. contact the
53| USB/TYPE-C/PD Locked| dea kr if the tiro! still exists after rebooting the unit
54| 12V10A Locked| Disconnect the load to make sure the output power of
I frn’t Please
the s meet the of the unit. contact the
55| 12V30A Locked| dealer if the error still exists after rebooting the unit

Frequently Asked Questions

Q1:.The temperature of the adapter is getting high when I charge, is that alright?
A: It’s totally normal for the adapter to get warm, because of the heat produced in circuit during charging.

02: Why did the unit automatically shutdown with my appliance connected?
A: The “ECO MODE” (default) is set to shut down the unit when the AC output of the unit is lower than SOW in 4 hours for power saving.

03: What causes the cooling fan not to launch?
A: With the excellent heat dissipation design, the cooling fan will only launch when the total loads exceeds 30% of the rated output.

Q4: Can I charge and discharge the power station simultaneously?
A: Yes, it is supported, but not recommended in order to protect the lifespan of battery.

Q5: How to claim the warranty?
A: Please refer to the warranty card or the official website for further warranty policy.

Abbreviation Explain
DC/AC= Direct Current/ Alternating Current
BMS = Battery Management System
PV = PhotoVoltaic (Solar Power)
CS = Charging State

AC Output

Energizer PPS2000 LiFePO4 Battery Portable Power Station - Ac
Output

A.Plug the power cable of AC appliance into the AC outlet of the machine. Press the power button to enter AC mode.
B.Make sure the power of the connected AC applianced is less than 100V2000W, 110V/120V 2100W

Notes:
In the case of no operation, the LCD back-light will turn off after 1 minute as default.
This time can be adjusted through the screen to 30 seconds, 1 minute, 5 minutes, and steady on. When the machine is in standby state, it will automatically shut down for 24 hours.
In ECO mode, the AC output is automatically turned off 4 hours after the AC output is unloaded. When the AC power is not in use, please turn off the AC power.

Protection mode: (AC output)
A.This product has undervoltage protection, overload protection and short circuit protection. The overtemperature protection is a double insulated circuit which is safe, reliable and efficient.
B.When overload, overtemperature or short circuit occurs, this machine will start beeping and the AC icon on the screen will flash, and then the machine automatically shut down to ensure safely.

Package Content

Energizer PPS2000 LiFePO4 Battery Portable Power Station -
packageEnergizer PPS2000
LiFePO4 Battery Portable Power Station - package 2

Caution

  1. Do not short-circuit the product. To avoid short-circuiting, keep the product away from all metal objects.
  2. Do not heat the product, or dispose of it in fire, water or other liquids. Keep it away from high ambient temperature. Do not expose the product to direct sunlight.
  3. Keep the product away from humid, dusty places.
  4. Do not disassemble or reassemble this product.
  5. Do not drop, place heavy objects, or trample on this product.
  6. This product is not intended to be used by a person with reduced physical, sensory or mental capabilities.
  7. Please keep this product away from children.
  8. Do not cover the product with towels, clothing and other items.
  9. Do not overcharge this product.
  10. When fully charged, disconnect the product from the power source immediately.
  11. If you are not going to use this product for a long time, please disconnect the cable before storing it.
  12. To charge some portable electronic devices, you may need to set those devices in charge mode first. Refer the corresponding user manual of those devices for confirmation.
  13. Do not pull the socket cover of the 12V DC Charging Port too hard, the tether could break.

Pure Sine Wave Output
This product generates pure sine wave, which is compatible with AC electric appliance that works with Sinusoidal wave form (power < 2000W). The product is perfect for off-grid power needs or backup power for emergency situations. However, it cannot  replace the standard DC or AC power supply for household appliances.
Warranty
Our company provides customers with warranty of 12 months from the date of purchase.
Customer Service: energizer@iittechnology.com
© 2022 Energizer Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by Tennrich International Corp

Made in China

Documents / Resources

| Energizer PPS2000 LiFePO4 Battery Portable Power Station [pdf] User Manual
PPS2000 LiFePO4 Battery Portable Power Station, PPS2000, LiFePO4 Battery Portable Power Station, Battery Portable Power Station, Portable Power Station, Power Station
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals