Energizer Arc3 Portable Power Station User Guide

June 3, 2024
Energizer

Energizer-logo

Energizer Arc3 Portable Power Station

Energizer Arc3 Portable Power Station-fig1

Using the Arc

Energizer Arc3 Portable Power Station-fig2

  1. Press and hold power button for 1 second to turn on the unit.
  2. Press the AC button to power on the AC outlets.
  3. The icon will appear on the display to show the output is on.
  4. Plug in your devices and power up.
  5. After use, press the AC button to power off the AC outlets.
  6. To turn off all ports and power down press and hold the power button for 1 second.

POWER CONSUMPTION AND DISTRIBUTION

Energizer Arc3 Portable Power Station-fig3

Important!

Energizer Arc3 Portable Power Station-fig4

LCD Display

  • A- Battery Charge
    How much battery power is left.

  • B- Time Remaining
    Run time remaining at the current power draw.

  • C- High Temperature Warning
    It’s too hot! Cool down the battery.

  • D- Low Temperature Warning
    It’s too cold! Warm up the battery.

  • E- Cooling Fan
    The fan will run when the battery gets hot, this is normal.

  • F- Low Battery
    The battery is getting low, recharge it.

  • G- AC Output
    Indicates AC output is on.

  • H- USB Output
    Indicates USB output is on.

  • I- USB Type-C Output
    Indicates USB Type-C output is on.

  • J- DC Output
    Indicates DC output is on.

  • K- Watt Meter
    Current input or output in Watts.

Not Recommended
(Over 350W Consumption)

Energizer Arc3 Portable Power Station-fig6

FAQs

  • Can I fly with the Arc3?
    No. FAA regulations allow a maximum of 100Wh baeries on a plane. Arc3 is 300Wh.

  • Do I need to calibrate my battery remaining meter?
    Only if you notice a major difference between the predicted time le and how long your Arc is actually running. Calibrate your Arc’s baery runtime meter by charging to 100%, discharging to 0% (until the unit turns off), then charging back up to 100%.

  • Can the Arc3 be stored and operated indoors?
    Yes, lithium-iron phosphate cells do not exhaust any fumes and are completely safe.

  • Can I recharge while powering devices at the same time?
    Yes, the Arc3 is equipped with pass-through charging which means you can recharge the Arc3 while using it to power devices at the same time.

  • Can I use both AC and DC ports at the same time?
    Yes, Arc3 supports simultaneous operation. All ports can be used at once, provided the total draw is less than 350W.

  • What will happen if I plug in a device that draws over 350W?
    The unit will stop operation and display an overload error message. Press the AC buon to turn off and turn on again to reset the system.

  • How long will it keep a charge?

    • 1 Year. It’s best for your baery’s health to charge every 3 months and store at 40-50%.
    • Do not store at 0% charge, lithium-iron baeries lose 3-5% charge per month. Within a few weeks your unit may be below the charge level needed to accept a recharge and permanent damage has been done.
  • Can I use this with my CPAP machine?
    Absolutely. CPAP operation using DC ports (with CPAP converter) will allow longer runtime than AC ports. Runtime will differ greatly based on heat, humidity, and pressure seings.

  • Can the Arc3 jump-start a car?
    No, a jump start port is not available on this unit.

  • Can I charge the Arc3 with a generator?
    Yes, it will charge in 5hrs. An inverter generator is recommended.

  • Can I combine two solar panels to achieve a faster charging rate?
    Yes, as long as the combined output voltage of the panels is between 12V -24V.

  • Will Arc3 automatically shut down with no power draw?
    Yes, it will shut down aer 10hrs. This duration was designed to ensure fridges operate properly.

  • Will the USB-C PD (Power Delivery) Port power my Laptop?
    Yes, it can provide up to 60W of charging power.

  • How much power is drawn if a port is left on accidentally?
    About 1.5W per hour with a max of 15W total.

  • Can I buy parts to fix my Arc3 after the warranty has expired?
    Yes, please visit our website for more information.

Troubleshooting Guide

Problem| Solution

If the AC icon on the digital display is blinking the unit has overloaded. Press the AC bu on to turn off and turn on again to reset. Max power limit for AC is 350W.

---|---

My Arc3 shut down while powering my device.

| If the High Temperature icon     on the digital display is blinking: Turn all ports off and remove unit from heat source. Do not use until unit has cooled and the icon disappears. Then turn the output on and try again. Excessive heat will degrade the ba ery’s life span.
| If the Low Temperature icon     on the digital display is blinking: Turn all ports off and remove unit from the cold. Do not use until unit has warmed and the icon disappears. Then turn the output on and try again.
My device|

Ensure the power switch for the output you want to use is on. For example if you want to charge your phone turn USB on, then plug in your phone.

is not
receiving
power.

My Arc3 charge level is fluctuating.

| If the ba ery is very low, the Arc3 can’t read the charge as accurately. As it receives a charge the accuracy will increase.
Your ba ery meter may need recalibration by charging to 100%, draining to 0% (until the unit turns off), then charging back up to 100%.
My Arc3 is not charging.| Ensure that you are using the port labeled “input”, noted by the red circle that surrounds it. Ensure that all components are firmly connected.

My Arc3’s

|

Use a paperclip to restart your unit by pressing the factory

screen| reset bu on (restart) on the front control panel. The unit will
stopped| then reboot. If this does not solve your issue please call our
responding.| technical support team.

Battery Education 101

Device Runtime | AC vs. DC Power
In general, it is normal for power losses to occur when energy is transferred from the battery to the ports that power your devices.
The AC port requires an inverter, which transforms power from DC to AC. This process creates heat and consumes about 15% of the power it transforms. DC ports are more efficient and only consume 5% of the power that is transformed.
Your device will always last longer when plugged into DC ports if that option is available. For example, a CPAP machine will last almost an extra night when using a DC CPAP converter compared to the standard AC plug.

Heat is the Enemy
If the Arc, or any power station, is left in the heat it will impact its health, capacity and longevity. Keep out of hot cars and direct sunlight on warm days. Heat is the #1 reason batteries degrade prematurely.

Determine The Power Consumption of Your Device
Device with no battery: locate Watts (W) on the product. If Watts are not available: multiply the Voltage (V) x Amps (A) to arrive at Watts. Eg. 120V x 0.6A 72W
Device with a battery: locate Watt Hours (Wh). Or multiply the Voltage (V) x Amp Hours (Ah) to arrive at Watt Hours (Wh). Eg. 12V x 1.0Ah = 12Wh (Note: 1.0Ah = 1000mAh)

Calculate Working Time or Recharges for your Device

AC Outlets Working Capacity
300Wh x O.85 (15% inverter conversion loss) = 255Wh
Working capacity. For example, assume your fan consumes72W. To calculate working time: 255Wh + 72w = 3.5 hrs
DC and USB Outlets Working Capacity 300Wh x O.95 (5%6 DC conversion loss) = 285Wh working capacity. For example, assume your smartphone has a 12.3Wh capacity battery. To calculate the number of recharges before capacity IS depleted, use the formula: 285Wh+12.3Wh = 22 recharges.

Regulated 12V vs Non-Regulated 12V
Non-regulated 12V ports are linked to the charge percentage of the battery. For example, when a power station is at 100% charge the DC voltage will operate at approximately 12V, which is acceptable for 12V devices. But as the battery charge drops to 50% the DC voltage will drop to approximately 10.8V. 12V devices such as mini-fridges/coolers, CPAP machines, vacuums, radios etc., will simply stop running when the voltage drops below -1V.
The Arc3 does not have regulated ports but it’s 12V ports are optimized to output up to 14 Voits on a full charge and a minimum of 12 Volts when the battery is almost depleted. This ensures devices, such as electric coolers, keep running no matter how much charge is remaining.

Specifications

Energizer Arc3 Portable Power Station-fig8

Warranty Claim Procedure

Do not return your product where purchased. If you feel your power station is not meeting your expectations, simply contact our customer support center support@energizerarc.com for technical advice, a warranty claim or general information. Keep a copy of the original receipt, UPC code and serial number with this user guide.

Register Online
www.energizerarc.com/register-your-warranty

Safety

  • DO NOT disassemble, repair, or modify the unit or the baery.
  • DO NOT place the unit close to fire, heat sources, or leave in direct sunlight.
  • DO NOT connect the output socket to mains power under any circumstances.
  • DO NOT expose to moisture or liquids, especially saltwater.
  • Dispose of the unit properly according to local regulations.
  • DO NOT dispose in regular household trash.
  • DO NOT operate the unit above the specified input voltage, be especially careful with solar panels.
  • DO NOT use this unit if your hands are wet.
  • DO NOT use if the unit appears damaged.
  • This product IS NOT permied on aircra.
  • Inspect the unit prior to every use.
  • Keep this product away from children and pets.
  • Carefully read the instructions for the electric devices you intend to connect.
  • Keep away from direct sunlight, water, dust, and dirt.
  • DO NOT leave the unit outside in harsh environments.
  • High temperatures can damage the baery and decrease the lifecycle and capacity.
  • DO NOT leave outdoors overnight uncovered. The moisture from the dew may lead to a short circuit.

Warranty

  • Limited warranty period for recreational and residential use: Two Years Limited
  • 1st Year: Parts and Labor
  • 2nd Year: Parts
  • This product is warranted to be free of defects in material and workmanship for two years from date of purchase and does not restart at any time under any circumstances. This warranty guarantees that any defective parts will be repaired or replaced at no cost, including diagnosis and replacement parts.
  • Limitation of remedies and disclaimers: Energizer Generators disclaims any responsibility for loss of time or any other incidental or consequential damage. Any implied warranties are limited to the duration of this wrien warranty.
  • THE FOREGOING LIMITED WARRANTY IS EXCLUSIVE OF AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND OF ANY OTHER WARRANTY WHETHER EXPRESS OR IMPLIED.
  • Exclusions not covered by this limited warranty: damage to products caused by accident, negligence, misuse, abuse, modification, improper installation, improper storage, water, liquid or gas of any kind, operation in a marine application, operation with improper loads or conditions, modifications contrary to published specifications, accessories not supplied by Energizer Generators, repairs made during the warranty period without first obtaining a case number from Energizer Generators, or use for anything other than the intended use as outlined by Energizer Generators.
  • Energizer Generators products are distributed by: Midland Power Inc., 376 Magnetic Drive, Toronto, ON M3J 2C4, Canada.

CONTACT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>