AVANTCO REFRIGERATION 178DLC82HCW Refrigerated Deli Cases

Product Information

The Refrigerated Deli Cases come in 12 different models with varying sizes and capacities. The models are #178DLC36HCB,

  • 178DLC47HCS, #178DLC64HCW, #178DLC36HCS, #178DLC47HCW,

  • 178DLC82HCB, #178DLC36HCW, #178DLC64HCB, #178DLC82HCS,

  • 178DLC47HCB, #178DLC64HCS, and #178DLC82HCW.

The product has a defrost system, digital temperature control units, and a condenser coil that requires cleaning.

Product Usage Instructions

It is recommended to read the user manual in its entirety before setting up, operating, or maintaining the equipment. Prior to installation, ensure the cabinet location guidelines are followed to ensure optimal performance. The electrical setup must be done carefully to avoid any damage to the compressor. The temperature controls can be adjusted using digital control units. To change the minimum temperature setting, hold SET for 1 second and use the arrow buttons to adjust the temperature. Press SET again to save your settings. It is important to note that the defrost system must be properly maintained to avoid any damage to the unit. During operation, ensure that there are at least 4 inches of clearance from the evaporator and avoid placing an excessive amount of warm product in the cabinet. Cleaning the fan blades and motor, the interior of the unit, and the condenser coil is crucial for maintaining optimal performance. Disconnect power before cleaning any parts of the unit. Cleaning the condenser coil requires disconnecting power, removing the front cover and base cover with a screwdriver, cleaning with a commercial condenser coil cleaner, straightening any bent condenser fins with a fin comb, and reinstalling the front cover and base cover. If any issues arise, refer to the troubleshooting section of the manual for possible causes and solutions. It is strongly recommended that any servicing of the unit be performed by an authorized service technician.

Warnings

  • DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED
    SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING.

  • CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR MANUAL/OWNER’S
    GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS MUST BE FOLLOWED.

  • CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW HANDLING
    INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.

  • CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW HANDLING
    INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT REGULATIONS.

Installation

This unit is intended for use in a temperature-controlled environment of less than 75°F and 55% relative humidity. Malfunction due to improper conditions is not covered under warranty.
Before Installation

  • If the unit has recently been transported on its side, please let unit stand upright for a minimum of 24 hours before plugging it in.
  • Make sure that there is proper ventilation around the unit in the area where it will operate.
  • Make sure all accessories are installed (i.e., shelves, shelf clips, casters) before plugging the unit in.
  • Do not attempt to remove or repair any component of the unit. Consult an authorized service technician for servicing/repair.
  • Do not hang on doors or sit inside the unit.
  • Please read through the manual in its entirety.
  • The unit should be located away from doors, air ducts, and fans that could disrupt airflow and negatively impact performance.

Cabinet Location Guidelines

  • Install the unit on strong and leveled surfaces.
    • If the surface is uneven, the unit may be noisy.
    • The unit may malfunction if the surface is uneven.
  • Install the unit in an indoor, well-ventilated area.
    • For best performance, please maintain clearance of 6” on the back of the unit.
    • Brackets should be attached on the back of the unit.
    • Do not use outdoors. For indoor use only.
    • Avoid direct sunlight.
  • Avoid installation in a high humidity and/or dusty area.
    • Humidity above 55% can cause the unit to rust, collect condensation, and may decrease efficiency.
    • Dust collected on condenser coil will cause unit to malfunction.
    • Malfunction due to temperatures above 75 degrees Fahrenheit, humidity above 55%, or improperly maintained condenser coil will void the warranty.
  • Select a location away from heat and moisture-generating equipment.
    • Ambient temperatures above 75 degrees Fahrenheit may cause the compressor to malfunction.
    • Malfunction due to ambient temperatures above 75 degrees Fahrenheit will void warranty.
    • Do not install the unit inside a closet or alcove.

Electrical

  • Ensure that the required voltage is being supplied at all times.• The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current protection. Refer to the electrical requirements on the unit’s nameplate.
  • The unit should have its own dedicated outlet.
  • DO NOT use extension cords.
  • Ensure the unit is not resting on or against the electrical cord.
  • If the unit is not in use for a long period of time, unplug from the outlet.
  • To avoid shock and fire hazards, DO NOT plug in or unplug the unit with wet hands.
  • After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause damage to the compressor.

Temperature Controls

Adjusting the Temperature

  • Your new refrigerator is already factory-set to run at optimum temperatures for food safety and should require no adjustments.
  • Refrigerators are set to cycle between a minimum temperature of 33°F and a maximum temperature of 40°F.
  • Adjusting the temperature changes the minimum temperature at which your unit will run. Your unit will not run constantly at this setting. To change it, follow these instructions:

Digital Control Units

  1. Hold “SET” for 1 second. The display will flash the current minimum temperature.
  2. Use the arrow buttons to adjust the minimum temperature you’d like the unit to run at.
  3. Press “SET” again to save your settings.
    • Always remember to calculate the differential if you change the minimum temperature setting. The cabinet temperature will fluctuate up to 7°F over your set minimum temperature as the compressor runs and shuts off. Setting the temperature too high will result in unsafe maximum temperatures and
    possible health code violations.

Operation

Defrost System

Automatic Defrost Cycle
  • Refrigerator coils are kept below the freezing point (32°F).
  • During compressor downtime, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost.
  • Run-off water is drained into the evaporator pan and evaporated.
  • Automatic defrost timers initiate at pre-set intervals and for a pre-determined duration. Running a Manual Defrost Cycle
  • Units are pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to run a manual defrost cycle at any time, follow the steps below. Only models with digital controls can run a manual defrost cycle. Units with mechanical controls cannot run a manual defrost cycle.
  • Controller #1: Press the defrost button (“DEF” and ▼) for approximately 5 seconds. Repeat to stop the defrost cycle.
  • Controller #2: Press the defrost button (Snowflake and ▼) for approximately 3 seconds. Repeat to stop the defrost cycle.

Safety Information

Pay close attention to the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit.

  • To minimize shock and fire hazards, be sure to not overload outlet. This unit should be given its own outlet.
  • DO NOT use extension cords.
  • DO NOT put your hands under the unit while it is being moved.
  • When the unit is not in use for a long period of time, unplug the unit from the outlet.
  • After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause damage to the compressor.
  • To minimize shock and fire hazards, do not plug or unplug the cord with wet hands.
  • Unplug the unit before performing maintenance or cleaning.
  • To minimize shock and fire hazards, make sure that the unit is properly grounded.
  • DO NOT attempt to remove or repair any component unless instructed by the factory.
  • DO NOT allow the unit to rest on or against the electrical cord and/or plug.
  • DO NOT hang on the doors.
  • DO NOT store any flammable/explosive gas or liquids inside the unit.
  • DO NOT attempt to alter or tamper with the electrical cord.
  • DO NOT use the unit if the power cord is damaged.

Operation/Maintenance

DISCONNECT THE POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
It is strongly recommended that any servicing of the unit be performed by an authorized service technician.
Loading Product

  • Do not block the air vents.
  • Ensure all shelves are sitting level and properly secured before loading products.
  • DO NOT store flammable and explosive gas or liquids inside the unit. Ensure there is at least 4″ of clearance from the evaporator.

Cleaning the Fan Blades and Motor

  • If necessary, clean the fan blades and motor with a soft cloth.
  • If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.

Cleaning the Interior of the Unit

  • When cleaning the cabinet interior, use a solvent of warm water and mild soap.
  • Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
  • Periodically remove the shelves and shelf brackets from the unit and clean them with mild soap and warm water.

Cleaning the Condenser Coil

  • For efficient operation, keep the condenser surface free of dust, dirt, and lint.
  • We recommend cleaning the condenser coil at least once per month.
  • A dusty condenser may lead to high energy consumption, less cooling effectiveness, and compressor damage.

Cleaning the Condenser Coil Instructions

  1. Disconnect the electrical power from the unit.
  2. Remove the front cover and base cover with a screwdriver.
  3. Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a vertical direction.
  4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Ex. Noble Chemical Tech Line Coil Cleaners (148TLECCCLNR, 148TLHDCCLNR, 148TLECOILDD, 148TLFMCCLNR, 147TLEVPCLNR, or 147TLHDCCLNR).
  5. After cleaning, straighten any bent condenser fins with a fin comb.
  6. When finished, be sure to reinstall the front cover and base cover.
  7. Reconnect the electrical power to the unit.

Troubleshooting

Problem Possible Cause Possible Solution


Compressor not running.

| Fuse blown or circuit breaker tripped.| Replace fuse or reset circuit breaker.
Power cord unplugged.| Plug in power cord.
Thermostat set too high.| Set thermostat to lower temperature.
 | Cabinet in defrost cycle.| Wait for defrost cycle to finish.




Condensing units run for long periods of time.

| Excessive amount of warm product placed in cabinet.| Allow adequate time for product to cool down.
Prolonged door opening or door ajar.| Ensure doors are closed when not in use. Avoid opening doors for long periods of time.
Dirty condenser coil.| Clean the condenser coil. (Page 7)
Evaporator coil iced over.| Unplug unit and allow coil to defrost. Make sure thermostat is not set too cold. Ensure that door gasket(s) are sealing properly.







The cabinet temperature is too warm.

| Thermostat set too warm.| Set thermostat to lower temperature.
Airflow blocked.| Re-arrange product to allow for proper air flow. Make sure there is at least four inches of clearance from evaporator.
An excessive amount of warm product placed in a cabinet.| Allow adequate time for product to cool down.
Fuse blown or circuit breaker tripped.| Replace fuse or reset circuit breaker.
Dirty condenser coil.| Clean the condenser coil. (Page 7)
The evaporator coil iced over.| Ensure doors are closed when not in use. Avoid opening doors for long periods of time.
Low refrigerant levels.| Contact a service technician to check refrigerant levels.
The door is slightly ajar.| Make sure door is completely closed.
Condensation is collecting on the cabinet and/or floor.| ****

The relative humidity is above 55%.

| ****

Move the unit to the area below relative humidity or lower humidity level.


The interior light is not working.

| Poor switch connection.| Turn off the light switch and turn it back on.
The bulb is not connected.| Make sure the bulb is correctly inserted in the socket.
Bulb has burned out.| Replace the bulb.

In case of an alarm and error code shown on the controller, please find a solution in the controller manual.
Note: You should read this manual in its entirety prior to equipment setup, operation, and maintenance.
www.AvantcoRefrigeration.com.