Energizer ENPP01800USBL Solar Peak 1800 User Manual

June 1, 2024
Energizer

Energizer ENPP01800USBL Solar Peak 1800

Specifications

  • General: Net Weight: 22kg (48.5lbs),
  • Dimensions: 432 x 270 x 300mm (17 x 10.6 x 11.8)
  • Battery Capacity: 1229Wh, 51.2V, 24Ah
  • WiFi: Supported

Product Overview

The Energizer Solar Peak 1800 is a portable power station that provides multiple output options for various devices.

Product Usage Instructions

AC Charging

To charge the power station using AC power, connect the provided AC adapter to the input port on the power station and plug the adapter into a standard wall outlet.

PV Charging

For PV charging, connect a compatible solar panel to the designated input port on the power station. Ensure the solar panel is receiving an adequate amount of sunlight for efficient charging.

Car Charging

To charge the power station using a car charger, connect the charger to the designated input port on the power station and plug it into your vehicle’s power outlet.

Intelligent Inversions

The power station features intelligent inversion modes for both inverter and bypass operations, allowing you to choose the power source accordingly.

FAQ

  • Error Messages & Solutions
    • Error Message: Low-temperature protection activated
    • Solution: Move the power station to a warmer environment and allow it to reach optimum operating temperature before recharging.
    • Error Message: Overload protection triggered
    • Solution: Disconnect excess devices and reduce the load on the power station to prevent overload.
  • What’s in the Box?
    • Energizer Solar Peak 1800 Power Station
    • AC Adapter
    • User Manual

Parameters

General

  • Net Weight /22kg (48.5lbs)
  • Dimensions (W x H x D)/ 432 x 270 x 300mm (17” x 10.6” x 11.8”)
  • Battery Capacity 1229Wh/ 51.2V⎓,24Ah
  • WiFi/ Supported

Output (EU/FR/AU/ZA)

  • AC Output x 3 (Inverter mode) /Pure sine-wave, total 1800W (peak 3000W), 220-240V~(50/60Hz), 12A Max.
  • AC Output (Bypass mode)/ 220-240V~(50/60Hz), 1800W Max, 10A Max.

Output (UK)

  • AC Output x 4 (Inverter mode)/ Pure sine-wave, total 1800W (peak 3000W), 220-240V~(50/60Hz), 13A Max.
  • AC Output (Bypass mode)/ 220-240V~(50/60Hz), 1800W Max, 10A Max.

Output (US)

  • AC Output x 4 (Inverter mode) /Pure sine-wave, total 1800W (peak 3000W), 120V~(60Hz), 15A Max.
  • AC Output (Bypass mode)/ 100-120V~(60Hz), 1500W Max, 12A Max.

Other Outputs

  • USB-A1/A2 / 5V⎓3A, 9V⎓2A, 12V⎓1.5A, 18W Max.
  • USB-A3/A4 / 5V⎓2.4A, 12W Max.
  • USB-C x 2 / 5/9/12/15V⎓3A, 20V⎓5A, 100W Max.
  • Car Charger / 12.6V⎓10A, 126W Max.
  • DC5521 Output x 2 / 12.6V⎓3A

Car charge and DC5521 share power, 126W Max.

  • Inverter mode: the output AC power comes from the battery, not the grid.
  • Bypass mode : the output AC power comes from the grid, not the battery.

Input (EU/UK/FR/AU/ZA)

  • AC Input Power / 1800W Max., 10A
  • AC Input Voltage / 220-240V~(50/60Hz)

Input (US)

  • AC Input Power /1500W Max., 12A
  • AC Input Voltage / 100-120V~(60Hz)

Other Inputs

  • PV Panel /13-45V⎓12A, 400W Max.
  • Car Charging Input /12V/24V Battery Supported, 8A by default

Input Charging

  • AC Charging Power / 1200W Max.
  • PV/Car Charging Power x 2 / 400W Max.
  • AC+PV Charging Power / 1200W Max.

Battery

  • Cell Type / Lithium Iron Phosphate Battery (LiFePO4)
  • Life Cycle / 3,000 cycles
  • Protection Type/ Over temperature protection, low-temperature protection, over-discharge protection, overcharge protection, overload protection, short-circuit protection, over-current protection

Operating Temperature

  • Optimum Operating Temperature: 20°C ~ 30°C (68°F ~ -6°F)
  • Discharge Ambient Temperature: -20°C ~ 45°C (-4°F ~ 113°F)
  • Charge Ambient Temperature: 0°C ~ 45°C (32°F ~ -113°F)
  • Storage Ambient Temperature : -20°C ~ 45°C (-4°F ~ 113°F)

Whether the product can be charged or discharged is subject to the actual battery pack temperature.

Safety Guidelines

Warning

  1. Do not let a working power station be close to a heat source, such as a fire or a heater.
  2. Do not let the power station come into contact with any liquid.
  3. Do not use the power station in a strong electrostatic or strong magnetic field environment.
  4. Do not disassemble the power station in any way or pierce it with a sharp object.
  5. Do not use wires or other metal objects to short-circuit the product.
  6. Avoid stepping, sitting or climbing on the power station.
  7. Do not use parts or accessories that are not officially supplied. If a replacement is required, please contact Energizer Solar at www.energizersolar.com.
  8. When using the power station, please follow the temperature guidelines outlined in this user manual. Excessively high temperatures can lead to a risk of battery ignition, while excessively low temperatures will significantly compromise the power station’s performance and  may affect its normal operation.
  9. Do not place heavy objects on top of the power station.
  10. Do not forcibly stop the fan or expose the power station to unventilated or dusty environments while it’s operating.
  11. Please avoid dropping and violent vibrations. If severe impact happens, shut down the power station immediately. Please secure the power station during transportation to avoid vibration and impact.
  12. If the power station accidentally falls into water, place it in a safe and spacious area, and maintain a safe distance until its completely dry. Even after the product has dried do not attempt to use the product again. Dispose of it properly according to the discard section in this user manual. If the power station is on fire, please use the recommended fire extinguishing methods in the following order: water or water mist, sand, fire blanket, dry powder, and a dioxide carbon fire extinguisher.
  13. 13. If the surface is dirty, clean it with a microfibre cloth.
  14. 14. Handle the power station with care to prevent damage. In the event of a severe impact causing the power station to tip over and sustain significant damage, turn it off immediately. Place the power station in a well-ventilated area, away from flammable materials and people. Dispose of it in accordance with local laws and regulations.
  15. Keep the power station out of the reach of children and pets.
  16. Keep the power station in a dry and ventilated place.
  17. In humid environments, such as seaside locations or areas near water, it is advisable to use a moisture-proof bag with the power station. If you discover water inside the power station, refrain from using or starting it again. Take precautions to prevent electric shock before handling the power station. Place it in a safe, waterproof location and promptly contact customer service.
  18. It is not recommended to use the power station to provide power for safety-critical emergency medical equipment, such as medical-grade breathing machines (hospital version CPAP: Continuous Positive Airway Pressure) and artificial lungs (ECMO: Extracorporeal Membrane Oxygenation). However, it is suitable for powering a home version of CPAP at home, which does not require continuous professional monitoring. Always follow your doctor’s recommendations and consult Energizer Solar for any device usage restrictions. For general medical equipment, please monitor the power levels to ensure power does not run out.
  19. Power supplies generate electromagnetic fields that may interfere with implantable medical devices or the normal operation of personal medical devices, such as pacemakers, cochlear implants, hearing aids, and defibrillators.
  20. When the power station is connected to a refrigerator, it may automatically shut down because of the power fluctuation property of the refrigerator. When connecting the power supply to a refrigerator that stores medicine, vaccines or other valuable items, it is recommended to set the AC output to “Never off” in the Energizer Solar Portable Power App, so as to ensure continuous power. Users should pay attention to power consumption.
  21. During the push-pull movement of this product, it is strongly recommended to avoid placing other items on the power station.

Discard

  1. When conditions allow, ensure the battery is completely discharged before placing the power station in a designated battery recycling bin. The power station contains potentially hazardous batteries, so it is important not to dispose of them in regular waste bins. Refer to local laws and regulations for guidance on proper battery recycling and disposal procedures.
  2. If the battery cannot be fully discharged due to product malfunction, avoid placing it directly in the battery recycling bin. Instead, contact a professional battery recycling company for appropriate disposal.
  3. If the battery fails to restart after over-discharging, it should be safely disposed of as waste

Product Overview

Energizer-ENPP01800USBL-Solar-Peak-1800-fig1

Energizer-ENPP01800USBL-Solar-Peak-1800-fig2

LCD Screen

Energizer-ENPP01800USBL-Solar-Peak-1800-fig3

Battery capacity : When the power station is being charged, the SOC icon will flicker.

Wi-Fi connection status: The flickering icon indicates that power station is ready for pairing. The icon will keep flickering if a mobile phone and power station are connected by hotspot. After network connection succeeds, the icon will always be on. If connection fails, the icon will be off.

  • Please refer to Error Messages & Solutions for more details regarding error messages.

How to Use

Note: Long press the ON/OFF button to restart the BMS and clear the fault information.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig4

On and off

  • Press the main power switch to turn on the device, then the screen will be lit and the main power indicator will enter the slowly blinking light mode.
  • If no operation is performed to the power station for 5 minutes, the power station will enter a hibernation state and the LCD will automatically turn off. When there is a load change or operation to the power station, the LCD screen will illuminate automatically. Press the main power switch to turn on or turn off the LCD.
  • Press and hold the main power switch to toggle the LCD on or off. In the normal mode (the power is above 5%), the default standby time of this product is 2 hours; when the AC output switch is not turned on, and there is no charge or discharge for 2 hours, the product will automatically shut down, and the standby time can be set it on the Energizer Solar Portable Power App; when the power is 5% or below, the product will be forced to enter the low power mode. In the case of no charge or discharge, the product will adjust the standby time according to the power and automatically shut down.
  • In normal mode, long press the LED light button to exit the automatic shutdown setting, and the battery icon (  ) on the screen will flash. Long press again to enter the automatic shutdown setting, and the battery icon  will not flash. The automatic shutdown setting is to protect the battery from low power, exiting this setting may damage the battery life, please use it with caution.
  • Note: With no AC input active, long press the above AC output button, you can switch the AC off-grid output frequency  long press 2s to switch, and the AC output icon will flash 3 times after successfully switching.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig5

AC output

  • After ensuring that the main power is turned on, short-press the AC output power switch to turn on the AC output.
  • Short press the AC output power switch again to turn it off.
  • The default standby time of the AC output port is 1 hour. After 1 hour without any load on the AC output port of this product, the AC output power will be automatically turned off. In normal mode, long press the LED light button, the AC output power switch can exit the automatic shutdown setting, and the battery icon ( ) on the screen will flash.
  • Long press again, the AC output power switch enters the automatic shutdown setting, and the battery icon does not flash.
  • Long press the LED light button to exit the AC automatic shutdown setting: it is applicable to AC equipment below 10W and pulse working equipment.
  • When the AC output is not in use, turn it off to save power consumption.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig6

  • After the main power switch is turned on, press the 12V DC output power switch to enable the DC output port.
  • Press the 12V DC output power switch again to turn it off.
  • When the 12V DC output power switch is turned on, the power station does not shut down automatically

AC Charging

Quick charging technology is designed for AC charging. You can control the charging power via the AC charging speed switch. The slow charge mode is on by default when power station is turned on, and can be switched to quick charge mode by the button. Quick and slow charging mode switching can also be set by the Energizer Solar Portable Power App. If the current is continuously higher than 20A, the charging input port will start the self-protection function, and the charging overload protection switch will automatically trip. Press the charge overload protection switch to restore charging after confirming no fault.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig7

Quick charge and slow charge can be switched by the button.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig8

The charging power range can be adjusted by the Energizer Solar Portable Power App.

Please use the standard AC charging cable for fast charging. The AC charging cable should directly plug into a 10A (or above) wall-mounted socket. Energizer Solar is not liable for any damages resulting from the use of unofficial AC charging cables or failure to follow instructions.

PV Charging

Energizer-ENPP01800USBL-Solar-Peak-1800-fig9

Solar charging cable (DC7909)

  • Please follow the Energizer Solar Sunpack user manual to connect the solar panels.
  • Before connecting the solar panel, check whether its output voltage is within the power station specifications to avoid damage to the power station.
  • The interface of this product is DC7909. If you need an adapter cable from MC4 to DC7909, please contact Energizer Solarat at www.energizersolar.com on how to purchase.

Car Charging

Energizer-ENPP01800USBL-Solar-Peak-1800-fig10

Car charger cable (DC7909)

Power stations can be charged by a car charging port. It should be charged after the car starts, so as to avoid the car battery loss and failure to start. At the same time, ensure a good connection between the car charging port and the cigarette lighter. We take no responsibility for any loss caused by improper operation.

Intelligent Inversion

To avoid operation faults arising from charging overload, when the total output power is over the rated output power, the constant output power will be automatically enabled, so that the power station can supply power to the high- power device at the rated output power.

Please take note of the following while using constant power:

  1. The constant power output function is not enabled by default, which can be turned on or off by App.
  2. In the following cases, the constant power output function is not enabled:
    • (1) AC output turned on in charging status (bypass mode).
    • (2) Constant power output turned off.
  3. The constant power output function is more suitable for the heater and motor instead of all electrical equipment. It is not suitable for some electrical appliances with voltage protection (such as precision instruments). Constant power output function application is subject to actual testing.

Energizer Solar Portable Power App

You are able to view information and data and control this product via the Energizer Solar Portable Power App. To download the app, search for [Energizer Solar Portable Power] in the Google App Store or Apple App Store. Once downloaded, create an account and register your product to manage and control how you use your Energizer Solar Portable Power Station. For WiFi connection instructions, visit www.energizersolar.com and go to the resources page.

UPS Function

This product supports the UPS function when you are connecting the product to the power grid via the AC input port of this product through the AC charging cable. When connected to the power grid, the appliance can use the AC output port of the product. At this time, it is in bypass mode (AC power from the grid, not the battery); when the grid suddenly loses power, the product can automatically switch to the battery-powered mode within 14ms, which is the inverter mode (the AC power comes from the battery, not the grid). Please do not connect it to devices that require high uninterrupted power supply, such as data servers and workstations. Only use the product for this purpose after multiple tests to confirm whether it is compatible. It is recommended to use only one connected device when using this mode, and do not connect multiple devices at the same time to avoid overload protection of the product. If the device does not operate normally or data is lost due to failure to follow the instructions, our company will not bear the corresponding responsibility.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig11

Error Messages & Solutions 

Energizer-ENPP01800USBL-Solar-Peak-1800-fig12 Energizer-ENPP01800USBL-Solar-Peak-1800-fig13

Energizer-ENPP01800USBL-Solar-
Peak-1800-fig15

If there is a warning occurs during the use of this product, and the warning icon still does not disappear after restarting the device, please stop using it immediately (do not try to charge or discharge). If none of the above information can solve problem you encounter, please contact Energizer Solar at www.energizersolar.com

What’s in the Box

Energizer-ENPP01800USBL-Solar-Peak-1800-fig16

Maintenance

  • It is recommended to use or store the power station between the optimum operating temperature range. Ensure it is kept away from water, heaters, and metal surfaces.
  • For long-term storage, charge and discharge every 3 months, i.e. discharge to 0% then charge to 100%.
  • For safety reasons, avoid storing the power station at temperatures above 45°C (113°F) or below -20°C (4°F).
  • If the capacity is lower than 1%, please charge to 60%. Long-term storage with serious power shortages will cause irreversible damage to the battery cells and shorten the service life of the product.
  • If the battery capacity becomes critically low, and the device remains idle for an extended period, the product will enter deep sleep mode and can only be used again after being recharged.

Disclaimer

  • It is recommended to use or store the power station between the optimum operating temperature range. Ensure it is kept away from water, heaters, and metal surfaces.
  • For long-term storage, charge and discharge every 3 months, i.e. discharge to 0% then charge to 100%.
  • For safety reasons, avoid storing the power station at temperatures above 45°C (113°F) or below -20°C (4°F).
  • If the capacity is lower than 1%, please charge to 60%. Long-term storage with serious power shortages will cause irreversible damage to the battery cells and shorten the service life of the product.
  • If the battery capacity becomes critically low, and the device remains idle for an extended period, the product will enter deep sleep mode and can only be used again after being recharged.
  • The product features a built-in battery management system, which has various protection measures, including overcharge, over-discharge, overcurrent, short circuit, high and low temperature, and abnormal communication. During the use of this product, these protection mechanisms may activate and temporarily cause output interruption. Any potential loss stemming from accidental power interruptions while supplying power to specific equipment, such as medical devices or servers, is not the responsibility of Energizer Solar.
  • Before using the power station, please read this user manual to ensure understanding and proper use. After reading the user manual, please keep it safe for future reference. Improper operation may cause serious injury to yourself or others, or result in product damage and property loss. Once using the power station, you are deemed to have understood and accepted all terms and contents herein. Users are expected to take responsibility for their actions and any resulting consequences. Energizer Solar is not responsible for any losses that may occur if users do not adhere to the instructions in this user manual.
  • In compliance with laws and regulations, the company reserves the right of the final interpretation of this document and all related documents of this product. Subject to update, revision or termination without prior notice, please visit www.energizersolar.com for the latest product information

Stay powered up wherever you roam with the Energizer Solar Peak 1800. The unrivaled portable power station that ensures you’re always equipped with reliable, worry-free energy.

Energizer-ENPP01800USBL-Solar-Peak-1800-fig19

Energizer-ENPP01800USBL-Solar-Peak-1800-fig18

Discover the Energizer Solar

Portable Power range!

The Energizer Solar Portable Power range offers reliable and sustainable charging solutions for all your electronic devices. Harnessing the power of the sun, these portable power products provide a convenient and eco-friendly way to stay connected on the go. With advanced technologies and durable construction, Energizer Solar Portable Power ensures high performance and long-lasting power supply in any outdoor adventure or emergency situation.

energizersolar.com

ISED Statement

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and

Economic Development

Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates uses and can radiate radio frequence energy and,if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.if this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is conne cted.
  • Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirements. The devicecan be used in portable exposure conditions without restriction.
    This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body

North America

  • 888 Prospect Street, Suite 200 La Jolla California 92037
  • + 1 424 254 5344

Europe

  • The Black Church, St Mary’s Place Dublin D07 P4AX, Ireland
  • +353 1 254 8222

Australia

  • Level 35, 477 Collins St, Melbourne Victoria 3000, Australia

  • +61 1300 757 827

  • energizersolar.com

© 2024 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands is affiliated with the respective owners of their trademarks.

FAQS

What kind of battery is used

Lithium iron phosphate battery (LiFeP04).

What equipment can be connected to the AC output ports?

The AC output has high rating power and maximum power, which enables it to supply power to most household appliances. Suggest checking the equipment power prior to connecting and make sure the power of all equipment lower than rated power.

How to know the supply time

When in charge, the LCD shows the remaining charging time. The SOC flickers and input power is shown.

How to clean the unit

Clean the unit with a microfibre cloth.

How to store the unit?

Turn it off, and keep it in a dry and ventilated place. Do not expose it close to water. For long-term storage, suggest discharge to 0% and charge to 100% every 3 months to extend the service life.

Can it be taken on a plane?

No, the Energizer Solar Peak 1800 does not comply with aviation standards.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals