Honeywell HAC6 6000 BTU Window Air Conditioner User Manual
- June 17, 2024
- Honeywell
Table of Contents
Honeywell HAC6 6000 BTU Window Air Conditioner User Manual
IMPORTANT SAFETY INSTRUCTIONS
BEFORE YOU BEGIN Read these instructions completely and carefully.
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of ‘Troubleshooting Tips’ first, you may not need to call for service at all. The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of refrigerant is highly flammable. Please ensure that your air conditioner is installed correctly to avoid risk of fire.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
Warning
To reduce the risk of fire, electrical shock or injury when using your air
conditioner, follow the basic precautions below:
- Plug into a grounded 3 prong outlet.
- Do not remove the ground prong.
- Do not use a plug adapter.
- Do not use an extension cord.
- Unplug the air conditioner before servicing.
- Use two or more people to move and install the air conditioner.
R32 Refrigerant
The refrigerants used for air conditioners are environmentally friendly
hydrocarbons R32. This kind of refrigerant is highly flammable. Please ensure
that your air conditioner is installed correctly to avoid risk of fire.
Caution
- Please read the manual before installation, using, maintenance.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- Do not pierce or burn the appliance.
- The appliance shall be stored in a room without continuously operating sources (for example: open flames, an operating ignition gas appliance or an operating electric heater.)
- Please contact the nearest after-sale service center when maintenance is necessary. At the time of maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.
- The handling, installation, storage, servicing and disposal must comply with the provisions of gas-related national laws and regulations, and also national wiring regulation.
- It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner. Be aware that refrigerants may not contain an odour.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- Unit operation limits: Outdoor side 61~110°F, 80%RH, indoor side 61~90°F, 80%RH.
Electric Shock
- Plug into a grounded 3 prong outlet.
- Do not remove the ground prong.
- Do not use an adapter.
- Do not use an extension cord.
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.
LCDI Power Cord and Plug
-
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
-
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain deenergized until the device has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed.
The cord shield must not be connected to ground or to any exposed metal. -
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly.
To test the plug:
- Plug power cord into a wall outlet.
- Press the TEST Button, the circuit should trip and cut all power to the air conditioner.
- Press the RESET button for use.
If a test is performed and the indicator light remains ON, the current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommendations.
INSTALLATION INSTRUCTIONS
Prepare the Window
This air conditioner is designed to be installed in a standard double-hung window with a window width between 23” and 34” (584mm-863 mm).
The air conditioner can be installed without the accordion panels to fit in a narrow window opening. See the window dimensions.
The Lower Sash (the lower part of the window that moves up and down) must allowfor 14.5” of vertical dearance when open.
All supporting parts must be secured to firm wood, masonry, or metal.
The electrical outlet must be within reach of the power cord.
The air conditioner should be tilted about 3° for better drainage of condensate and rainwater.
NOTE Save the product packaging and installation instructions for future reference.
Store the air conditioner in the product box when not in use for an extended period of time.
Top Rail Assembly
The top rail must be assembled prior to installing the air conditioner in the
window.
Tools Needed: Phillips Head Screw Driver.
Attaching the Top Rail to the Air Conditioner
Remove the air conditioner from the box and place on a hard and flat surface.
Caution
When handling the unit, be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils.
-
Remove top rail from the top of the packaging.
-
Secure the top rail to the unit with the 3/8” screws.
Tools Needed:
3/8”Screws
4 Top Rail (With sponge) 1
NOTE: For safety reasons, all 4 screws must be used to attach the top rail.
Install the Accordion Panels
NOTE The top rail and sliding panels at each side are offset to provide the proper pitch to the rear of 5/16”. This is necessary for the proper condensed water utilization and drainage. If you are not using the side panels for any reason, this pitch to the rear must be maintained.
-
Place unit on a flat, stable surface. Hold the accordion panel in one hand and gently pull back the center to free the open end.
-
Slide the free end “I” section of the panel directly into the cabinet. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
-
Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet.
-
Slide the panel all the way in and repeat on the other side.
Storm Window Requirements
A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly.
To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1-1/2”. Make sure the board or piece of wood is approximately 1/2” higher than the storm window frame. This will allow the air conditioner to tilt enough for proper drainage.
Placing the Unit Inside a Window
Place the air conditioner on the sill with the bottom mounting rail against
its back edge. Center the air conditioner and close the window securely behind
the top mounting rail. The air conditioner should be 3° slightly tilted to the
outside area. Use a level, about a 1/3 bubble will be the correct case slant
to the outside. (It is suggested to keep a downward angle to let accumulated
rain water drain out from the back side of the unit bottom.).
Once the air conditioner is placed, extend both the left and right accordion
panels to the width of the window.
Place the frame lock between the extended accordion panels and the window
sill. Screw a 3/4” (19mm) locking screw through the frame lock anc into the
window sill.
Drive 1/2” screws into the top of the accordion panel frame and the top rail to securely attach the window air conditioner to the lower sash.
To secure the lower sash into place, use the sash lock and a 3/4” screw as shown below.
For added insulation, cut the supplied insulation foam to the width of the window.
Insert the foam between the window sashes to prevent air and objects from
getting into the room.
Removing the Air Conditioner from the Window
- Turn the air conditioner off and unplug the power cord.
- Remove the sash seal from between windows, and unscrew sash lock.
- Remove the screws installed through the frame and frame lock.
- Close (slide) the side panels into frame.
- Keeping a firm grip on air conditioner, raise the sash and carefully “rock” air conditioner backward to drain any condensate water in base of unit. Be careful not to spill any remaining water while lifting unit from window.
- Store parts with the air conditioner in the box.
Refrigerants R32
Read this section before installing the appliance. to avoid serious injuries when filling the combustible refrigerant.
- Requirements for the total weight of filled refrigerant and the area of a room to beequipped with an air conditioner.
- A leak test must be done after the installation is completed.
- It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant in order to ensure that the fire risk is reduced to minimum.
- It is necessary to operate the machine under a controlled procedure inorder to ensure that any risk arising from the combustible gas or vapor during the operation is reduced to minimum
Site Safety
- Open Flames Prohibited
- Ventilation Necessary
Operation Safety
- Mind Static Electricity.
- Must Wear Protective Clothing and anti-static gloves.
Installation Safety
- Refrigerant Leak Detector.
- Appropriate Installation Location.
Please note:
The installation site should be in a well-ventilated condition.
The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548°C which easily produces open fire.
When installing an air conditioner, it is necessary to take appropriate anti- static measures such as wear anti-static clothing and/or gloves.
It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or explosive environment.
If the indoor unit suffers refrigerant leak during the installation, all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user’s site.
It is necessary to choose the place where the inlet and outlet air of the indoor unit is even. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit, and also prevent mechanical damage from occurring.
USING YOUR AIR CONDITIONER
Operating Sounds
You may hear a pinging noise caused by water hitting the condenser, on rainy days, or when the humidity is high. This design feature helps remove moisture and improve efficiency. You may hear the thermostat click when the compressor cycles on and off. Water will collect in the base pan during rain or days of high humidity. The water may overflow and drip from the outside part of the unit. The fan may run even when the compressor is not on.
Digital Control Panel
Digital Display:
When the timer is not in use, the operation mode and the set temperature will
be displayed. Time will be displayed under the timer setting.
Mode Button:
Press the mode button to cycle through the various modes: Cool, Dry, Fan and
Auto.
Cool Mode: The cooling function allows the air conditioner to cool the
room and at the same time reduces humidity. Press the MODE button to activate
the cooling function. To optimize this function adjust the temperature by
pressing the up and down arrows and the speed by pressing the Fan Speed
button.
Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press the MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan is activated.
Fan Mode: This function only works when the air conditioner is vented. Press the MODE button to set the FAN mode. With pressing the FAN SPEED button, the speed changes in the following sequence: HIGH, MED, LOW in FAN mode.
Auto Mode: In AUTO mode the unit automatically chooses the mode of operation (COOL, FAN). In this mode the temperature is set automatically according to the room temperature (Room temperature is determined by the temperature sensor located in the indoor unit).
Note:
You may hear a pinging noise caused by water hitting the condenser. You may
hear the thermostat click when compressor on and off. The fan may operate even
when the compressor is off.
and Button
Use these buttons on the control panel and remote to increase or decrease the
Set Temperature or Timer. Long press the down button 3s can override the dr
mode. Temperature range: 61°F~88°F or 16°C~31°C.
Sleep Button
Press the SLEEP button, all of the display lights will turn off after a while,
but the Sleep” light is always on. In SLEEP mode, the air conditioner will
automatically adjust the temperature and fan speed to make the room more
comfortable during the night. The set temperature will automatically raise or
decrease based on the room temperature and the duration of sleep.
Eco Button
When the unit is in ECO mode, thelight will turn on. In ECO mode, the unit
will turn off once the room is cooled to the user-set temperature. The unit
will turn back on when the room temperature rises above the user-set
temperature. Before the compressor starts, the fan motor will run for a while,
then it will stop for a while, and will repeat to provide a much more
comfortable feeling and save energy.
Power Button
Turn the air conditioner on and off.
Filter Button
When the Filter Check light is off, it is not necessary to press the Filter
Check button.
When the Filter Check light is on, you can turn off the light by pressing the
Filter Check button. After the fan motor works for 500 total hours, the Filter
Check light will turn on to remind the user to clean the filter.
Timer Button
Use these buttons on the control panel and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button.
Set the rest time by pressing the button or until the rest time displayed is to your demand then press TIMER button again.
Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the button or . Press TIMER button at the second time, set the rest time with pressing the button or . Press TIMER button at the third time, confirm the setting, then it will show on the display.
Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the up and down arrow buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the setted function, press the TIMER button again.
Fan Speed Button
Press the FAN SPEED button to select the fan speed. In COOL MODE you can
choose the following settings: HIGH, MED, LOW , or AUTO. In FAN
MODE you can choose from HIGH, MED, LOW.
Directional Levers
Use the horizontal wheels to control horizontal airflow and the air deflectors
to control vertical airflow.
Remote
-
POWER
Turn the air conditioner on and off. -
COOL
Press the COOL button to COOL mode. -
AND
Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61°F~88°F or 16°C~31°C . -
SLEEP
Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise or decrease based on the room temperature and the duration of sleep. -
TIMER
Use these buttons on the control panel and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the up arrow button or down arrow until the rest time displayed is to your demand then press TIMER button again.
Timer On: When the unit is off, press TIMER button at the first time, set the temperature with pressing the up arrow button or down arrow button. Press TIMER button at the second time, set the rest time with pressing the up arrow button or down arrow button. Press TIMER button at the third time, confirm the setting, then it will show on the display.
Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the set function, press the TIMER button again. -
AUTO-MODE
In AUTO mode the unit automatically chooses the mode of operation (COOL, or FAN).
In this mode the temperature will be set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.). -
FAN SPEED
Press the FAN SPEED button to choose the fan speed options. You can choose HIGH, MED, LOW or auto speed in COOL mode and choose HIGH, MED, LOW in FAN mode. -
DISPLAY
To press the DISPLAY button, it can switch off/on all lights or LED display. -
ECO
When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user set temperature. The unit will turn back on when the room temperature rises above the user set temperature. Before the compressor starts, the fan motor will run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy. -
Fan Only
Press the Fan Only button to FAN ONLY mode
Battery Size:
AAA-NOTE: Do not mix old and new batteries or different types of AAA
batteries.
CARE AND CLEANING
To clean the air filter:
-
Take off the power plug, then remove the filter by sliding it out from the front right side of the air conditioner.
-
Wash the filter using liquid dish soap and warm water.
Rinse the filter thoroughly. -
Gently shake the filter to remove excess water.
-
Let the filter dry completely before placing it into the air conditioner.
-
If you do not wish to wash the filter, you may vacuum the filter to remove the dust and other particles.
Cabinet Cleaning
- front panel of the air conditioner may be dusted with an oilfree cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap. Rinse thoroughly with a damp cloth and wipe dry.
- Never use harsh cleaners, wax or polish on the cabinet.
- Wring excess water from the cloth before wiping around the controls.
Excess water in or around the controls may cause damage to the air conditioner.
Winter Storage
To store the air conditioner when it is not in use for an extended period of time, remove it carefully from the window according to the installation instructions and cover it with plastic or place it in the original box.
TROUBLESHOOTING
Problem | Possible Cause | Solution |
---|---|---|
Air conditioner does not start | Wall plug disconnected. House fuse blown or | |
circuit breaker tripped. Plug current device tripped. Power is off. | Push plug |
firmly into wall outlet. Replace fuse with time delay type or reset circuit
breaker. Press the reset button. Turn power on.
Air from unit does not feel cold enough.| Airflow is restricted The
temperature control may not be set correctly The air filter is dirty Cold air
is escaping| Make sure there are no curtains, blinds, or furniture blocking
the front of the air conditioner. Lower the set thermostat temperature. Clean
the filter (see section 4) Check for open furnace registers and cold air
returns.
The Air Conditioner is freezing up| Ice blocks the air flow and stops the air
conditioner from cooling the room| Set the MODE dial to HIGH FAN or HIGH COOL
and set the thermostat to a higher temperature.
Water is dripping inside the room| The air conditioner is not correctly tilted
outside| For proper water drainage, make sure the air conditioner is slightly
tilted downward from the front of the unit to the rear.
Water collects in the base pan| Moisture removed from the air is draining into
the base pan| This is normal for a short period inareas with low humidity and
normal for a longer period in areas with high humidity
If you want to return or replace the product, please contact the store where it was purchased (remember to bring the purchase invoice). If your product needs repair, please contact us via email or phone.
BHRS Group, LLC
585 Prospect St.
Lakewood, NJ 08701
Customer Service Tel:
1-888-604-0295
Customer Service Email:
support@honeywellcoolingappliances.com
Website:
honeywellcoolingappliances.com
©2023 BHRS Group, LLC. All Rights Reserved.
The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representations or warranties with respect to this product. This product is manufactured by BHRS Group, LLC.
MADE IN CHINA
Documents / Resources
|
Honeywell HAC6 6000 BTU Window Air
Conditioner
[pdf] User Manual
HAC6 6000 BTU Window Air Conditioner, HAC6, 6000 BTU Window Air Conditioner,
BTU Window Air Conditioner, Window Air Conditioner, Air Conditioner,
Conditioner
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>