innr SP 244 Zigbee Smart Plug Smart Outlet Instruction Manual

June 17, 2024
innr

innr SP 244 Zigbee Smart Plug Smart Outlet

Product Information

Specifications:

  • Rating: 120V AC 60Hz 15A (resistive)
  • Disconnection means: Type 1B
  • Pollution degree: 2
  • Rated impulse voltage: 1500V
  • Automatic action: 50,000 cycles

Product Usage Instructions

  1. Plug Bridge App
    Ensure the Smart App is plugged in and ready for operation.

  2. Search Mode
    Put the Smart App in search mode to enable device pairing.

  3. Manual ON/OFF
    To manually turn the device on or off, press and hold the corresponding button on the device.

  4. Pairing Mode
    To enter pairing mode, follow the instructions specific to your device model.

  5. Overload Protection
    The smart plug includes overload protection. If triggered, the plug will switch off and can be reset manually using the button on the device. It is recommended to discontinue use if overload occurs frequently.

FAQ (Frequently Asked Questions)

  • Q: What should I do if the overload protection is triggered frequently?
    A: If overload protection is triggered often, it indicates that the connected device’s power consumption is too high. It is advisable to stop using the smart plug with that device.

  • Q: How do I reset the smart plug after overload protection is triggered?
    A: You can manually reset the smart plug by pressing the button on the device after an overload event.

OVERVIEW

innr-SP-244-Zigbee-Smart-Plug-Smart-Outlet-FIG- \(1\)

FEATURES

innr-SP-244-Zigbee-Smart-Plug-Smart-Outlet-FIG- \(2\)

OPERATING INSTRUCTIONS

innr-SP-244-Zigbee-Smart-Plug-Smart-Outlet-FIG- \(3\) innr-SP-244-Zigbee-Smart-Plug-Smart-Outlet-FIG-
\(4\) innr-SP-244-Zigbee-Smart-Plug-Smart-
Outlet-FIG- \(5\)

CAUTIONS and OPERATING INSTRUCTIONS

  • CAUTION : RISK OF ELECTRIC SHOCK – DRY LOCATION USE ONLY
  • This device is for indoor use only.
  • The total current limit of the device is 15 A; to avoid damage, do not exceed the 15 A limit.
  • Make sure to use this product together with 15A
  • Not suitable for washing machines without “soft start” feature.
  • If a short circuit is created on the output, the Smart Plug will be damaged and no longer function.
  • For safety reasons, do not open this device, which will also void the warranty.
  • Only install in operating environments between 32°F – 100°F / -0°C – +40°C.
  • For cleaning, use a damp cloth, never a strong cleaning agent.
  • Do not clean the device when it is on and connected to the power supply.
  • This device is not a toy, designed to be played with by children.
  • Dispose of this device in accordance with disposal laws in your area.

Manual ON / OFF

Factory reset

innr-SP-244-Zigbee-Smart-Plug-Smart-Outlet-FIG- \(7\)

Pairing mode

innr-SP-244-Zigbee-Smart-Plug-Smart-Outlet-FIG- \(8\)

Overload Protection

The smart plug software includes an overload protection. If an overload occurs, the smart plug will switch off and can only be reset manually with the button on the device. Note that if the overload protection is triggered it is usually a sign that the power consumption of the connected device is too high for the smart plug. In that case it is strongly recommended to stop using the smart plug to control the connected device.

LIMITED WARRANTY

Innr warrants that this device will be free from defects in material and workmanship and will operate for 2 years based on up to 3 hours of average usage per day/7 days per week when used as directed. If this device does not conform to the warranty, Innr will send you, at its election, a replacement device or refund your original purchase price upon receipt of the returned device, register receipt, and proof of purchase. Please send an email to usaservice@innr.com to find out how to return the device. This limited warranty does not cover devices subject to accident, neglect, abuse, misuse or acts of God.
REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state and province to province.

Supplier’s Declaration of Conformity

SP 244
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Supplier’s name: Opened Box Returns LLC
Supplier’s address (USA): 1790 Swarthmore Ave., Unit 6,
Lakewood NJ 08701 USA
Supplier’s phone number and/or internet contact information: usaservice@innr.com
Caution : Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

FCC

Note : This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.

  • Rating : 120V AC 60Hz 15A (resistive)
  • Disconnection means : Type 1B
  • Pollution degree : 2
  • Rated impulse voltage : 1500V
  • Automatic action : 50,000 cycles

FCC Certification:

  • FCC ID: 2ANDL ZT2S

www.innr.com
© 2023 Innr Lighting B.V

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

innr User Manuals

Related Manuals