VEVOR YOILP-WS-32 Drum Pump User Manual

June 17, 2024
VEVOR

VEVOR YOILP-WS-32 Drum Pump

VEVOR-YOILP-WS-32-Drum-Pump-PRODUCT

Product Information

Specifications

Model| Max. Flow Rate| Rotation Times| Style| Available Drums| Material| Application
---|---|---|---|---|---|---
YOILP-WS-32| 19L/Min| Max.100rev/min| Rotary| 5~55gal NPT2| Cast Iron, Steel| Used for Diesel, Kerosene, Machine oil (Not for gasoline, paint
and water)
YOILP-HG0008| 23L/Min| Max.100rev/min| Rotary| 5~55gal NPT2| Aluminum| Used for Acid, Alkali, Urea, WaterDEF
YOILP-HG0012A| 24.6L/Min| Max.100rev/min| Rotary| 5~55gal NPT2| Polypropylene| Used for Acid, Alkali, Urea, WaterDEF

Structure Diagram Components

No.| Name| Picture| Qty of YOILP-WS-32| Qty of YOILP-HG0008| Qty of YOILP- HG0012A
---|---|---|---|---|---
1| U-Tube| | 1| 1| 1
2| Pump body| | 1| 1| 1
3| Cover Adapter| | 1| 1| 1
4| Filter| | 1| 1| 1
5| Handle| | 1| 1| 1
6| Suction tube| | 1| 1| 1
7| Suction tube sleeve| | –| 2| –
8| Hose| | 1| 1| 1
9| Clamp| | –| 1| –
10| PTFE tape| | –| 1| –

Product Usage Instructions

ASSEMBLY

Step 1: Assemble the suction tube and filter

  1. Take the three suction tubes and assemble them.
  2. Attach the filter to the assembled suction tube.
  3. Put the assembled suction tube and filter into the cover adapter.

Step 2: Attach the handle to the pump body

  1. Attach the handle to the pump body.
  2. Tighten the screw to secure the handle.

Step 3: Install the U-tube and hose

  1. Install the U-tube on the pump body using PTFE tape for sealing.
  2. Attach the hose to the U-tube.
  3. Lock the hose with the clamp.

Step 4: Install the suction tube on the pump body

Follow the diagram below to install the assembled suction tube on the pump body.

Operation

  1. Determine the proper length of the suction tube for your application and attach it to the pump.
  2. Insert the suction tube through the bung hole located on the container lid.
  3. Attach the cover adapter located on the bottom of the pump to the container lid.
  4. Pump the handle several times to prime the pump.
  5. Continue pumping until the desired volume of solution is delivered.

FAQ

Q: Can this pump be used for gasoline?

  • A: No, this pump is not suitable for use with gasoline.
  • It is designed for use with diesel, kerosene, and machine oil only.

Q: How often should I perform routine maintenance on the pump?

  • A: The pump and its components should be regularly inspected, and routine maintenance should be performed as required.
  • It is recommended to check for weak or worn spots in the hoses before each use and to check the security of all connections.
  • Additionally, all liquids should be dispelled from the pump and components before performing routine maintenance.

Q: What should I do if I have product questions or need technical support?

  • A: If you have any product questions or need technical support, please feel free to contact us at [email protected].
  • We are here to help!
  • We continue to be committed to providing you tools with at a competitive price.
  • Save Half”, “Half Price” or any other similar expressions used by us only represent an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and do not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are saving half in comparison with the top major brands.
  • This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual.
  • The appearance of the product shall be subject to the product you received.
  • Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

WARNING

  1. Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating.
  2. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.

GENERAL SAFETY RULES

  1. Select the appropriate product type according to the liquid type.
  2. Always keep hazardous, flammable, or combustible liquids, other fuels, and cleaners out of reach of children. Keep stored hazardous, flammable, or combustible liquids far from open flames or heat.
  3. A maintained fire extinguisher should be kept nearby when working with hazardous, flammable, or combustible liquids.
  4.  Adequate ventilation is essential! Clean up all spills immediately when pumping or handling flammable liquids.
  5. ABSOLUTELY NO SMOKING!
  6. DO NOT use torches or apply fire or flames to this pump, pump components, or any containers used with this pump.
  7. Be sure that the discharge line is secure before pumping. An insecure discharge line may slide, possibly causing personal injury and/or property damage.
  8. Over-tightening non-metallic fittings will strip threads. Once fitting is “hand tight” turn one more full rotation, this is usually enough to prevent leaking. Thread sealant can be used on all threaded joints, including the delivery spout.
  9. Before each use, check hoses for weak or worn spots. Check the security of all connections.
  10. Regularly inspect the pump and components, performing routine maintenance when required.
  11. Dispel all liquids from the pump and components before performing routine maintenance

MODEL AND PARAMETERS

**Model| ****YOILP-WS-32| ****YOILP- HG0008| ****YOILP- HG0012A
---|---|---|---
Max. Flow Rate| 19L/Min| 23L/Min| 24.6L/Min
**
Rotation Times| Max.100rev/min| Max.100rev/min| Max.100rev/min
Style| Rotary| Rotary| Rotary
Available Drums| 5~55gal NPT2| 5~55gal NPT2| 5~55gal NPT2
Material| Cast Iron, Steel| Aluminum| **** Polypropylene


**** Application

| Used for Diesel, Kerosene, and Machine oil (Not for gasoline, paint, and water)| Used for Acid, Alkali, Urea, Water,DEF

STRUCTURE DIAGRAM

VEVOR-YOILP-WS-32-Drum-Pump-FIG-1

  1. U-tube
  2. Pump body
  3. Cover Adapter
  4. Filter
  5. Handle
  6. Suction tube

COMPONENTS

VEVOR-YOILP-WS-32-Drum-Pump-FIG-2 VEVOR-YOILP-
WS-32-Drum-Pump-FIG-3

ASSEMBLY

Step 1: assemble the three suction tubes, assemble the filter(8), and then put them into the cover adapter(3), take YOILP-HG0008 as an example .VEVOR-YOILP-WS-32-Drum-Pump-FIG-4

  • Step 2: Attach the handle(5) to the pump body(2) and tighten the screw.
  • Step 3: Install the U-tube(1) on the pump body, make sure to use PTFE tape.
  • Install the hose(10) on the U-tube and lock it with the clamp(11).
  • Step 4: Install the installed suction tube on the pump body, as shown below.VEVOR-YOILP-WS-32-Drum-Pump-FIG-7

Step5:Operation:

  • Determine the proper length of the suction tube for your application and attach it to the pump.
  • Insert the suction tube through the bung hole located on the container lid,attach the cover adapter located on the bottom of the pump to the container lid.
  • Pump the handle several times to prime the pump.
  • Continue pumping until the desired volume of solution is delivered.
  • Above is the YOILP-HG0008 installation, and the installation of the YOILP-WS-32 YOILP-HG0012A is the same as that of YOILP-HG0008.

MAINTENANCE

  1. After each use of the product, it is recommended to clean it and keep it dry.
  2. When using this product to extract a variety of liquids, it is recommended to clean this product before extracting another liquid.
  3. If the pump has not been used for an extended length of time or has had low usage the pump should be flushed and cleaned.

TROUBLESHOOTING

THE PUMP IS NOT WORKING

  1. Check the suction tubes to be sure they are airtight. The pump will not pump if the suction tube allows air to enter. Thread sealing PTFE tape is recommended during assembly.
  2. Rinse the pump with water or the appropriate solution in regards to what was just pumped. Some chemicals may harden or cause the internal parts to swell, this prohibits the operation of the pump. You may need to open the pump body and clean the internal parts. While inside, visually review the vane for chemical permeation or swelling. If this has occurred replace the pump.
  • Sanven Technology Ltd.
  • Address: Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730
  • Made in China
  • TechnicalSupport and E-Warranty Certificate www.vevor.com/support

NEED HELP? CONTACT US!

  • Have product questions? Need technical support? Please feel free to contact us: at [email protected]

Documents / Resources

| VEVOR YOILP-WS-32 Drum Pump [pdf] User Manual