DOMETIC RM 2351 Absorption Refrigerator 3 Cu Ft Flexible Storage Owner’s Manual
- June 17, 2024
- Dometic
Table of Contents
- DOMETIC RM 2351 Absorption Refrigerator 3 Cu Ft Flexible Storage
- Product Information
- Product Usage Instructions
- Foreword
- Safety Instructions
- REFRIGERATOR OPERATION
- OPERATION INSTRUCTIONS
- AC VOLTAGE
- DC COMPONENTS
- LP GAS COMPONENTS
- COOLING UNIT
- WIRING
- ICE MAKER
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DOMETIC RM 2351 Absorption Refrigerator 3 Cu Ft Flexible Storage
Product Information
Specifications
- Product Name: Americana & Americana Plus
- Models: RM 2351, RM 2354, RM 2451, RM 2454, RM 2551, RM 2554, RM 2652, RM 2662, USA RM 2663, RM2852, RM2862 & NDR1062
- Service Office (USA): Dometic Corporation, 2320 Industrial Parkway, Elkhart, IN 46516
- Service Office (Canada): Dometic Distribution, 46 Zatonski Unit 3, Brantford, Ontario CANADA N3T 5L8
- Service Center Assistance: 800-544-4881
Product Usage Instructions
Safety Instructions
This manual contains safety information and instructions to help users
eliminate or reduce the risk of accidents and injuries. Please read and follow
all safety information and instructions provided.
Recognize Safety Information
The safety-alert symbol is used in this manual to indicate potential risks.
When you see this symbol, be alert to the potential for personal injury.
Follow recommended precautions and safe operating instructions.
Understand Signal Words
A signal word, Warning or Caution, is used with the safety-alert symbol to
indicate the level of risk for potential injury:
- Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
- Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
- If used without the safety-alert symbol, it indicates a potentially hazardous situation which, if not avoided, may result in property damage.
Frequently Asked Questions (FAQ)
-
Q: Where can I find the diagnostic flow chart?
A: The diagnostic flow chart can be found on page 4 of the manual. -
Q: How can I contact the service office in the USA?
A: You can contact the Dometic Corporation service office at 2320 Industrial Parkway, Elkhart, IN 46516 or call 574-294-2511. -
Q: What is the service center assistance number?
A: The service center assistance number is 800-544-4881.
Foreword
This service manual is the result of the dedication of The Dometic Corporation Technical staff and its engineers in giving service people the necessary instruction for making accurate analyses of certain conditions. Provided is a diagnostic chart leading a qualified mechanic into the service manual pages to locate and solve symptoms that may occur. Dometic has continued its commitment in providing service people with this, the most up-to-date information about servicing Dometic RV accessories.
Safety Instructions
This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries.
Recognize Safety Information
This is the safety alert symbol. When you see this symbol in this manual, be
alert to the potential for personal injury.
Follow recommended precautions and safe operating instructions.
Understand Signal Words
A signal word , WARN OR CAUT is used with the safety-alert symbol. They give the level of risk for potential injury.
WARNING Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION Indicates a potentially hazardous situation which, if not avoided
may result in minor or moderate injury.
CAUTION When used without the safety alert symbol indicates, a
potentially hazardous situation which, if not avoided may result in property
damage.
Read and follow all safety information and instructions.
This program will address the most common system problems associated with the RM2351, RM2354, RM2451, RM2454, RM2551, RM2554, RM2652, RM2662, RM2663, RM2852 and RM2862 refrigerators supplied by The Dometic Corporation. We intend to provide you with a guideline of checks to make, should you encounter one of the following symptoms.
REFRIGERATOR OPERATION
DISPLAY PANEL RM2351, RM2451, RM2551, RM2652, RM2852 AUTO TEMPERATURE CONTROL
AMERICANA 2-WAY MODEL
- Main Power Button ON/OFF
- AUTO/GAS Mode Selector Button
- A. AUTO Mode indicator lamp
- B. CHECK indicator lamp (Gas Mode Only)
- C. Climate control switch only on RM2652 & RM2862
DISPLAY PANEL RM2354, RM2454, RM2554 RM2663 3-way
DISPLAY PANEL RM2662, RM2862 2-WAY
3-WAY
- Main Power Button ON/OFF
- DC Mode Selector Button
- AUTO/GAS Mode Selector Button
- Temperature Selector Button
- A. DC Mode Indicator Lamp
- B. AC Mode Indicator Lamp
- C. GAS Mode Indicator Lamp
- D. AUTO Mode Indicator Lamp
- E. CHECK Indicator Lamp (Gas Operation Only)
- F. Temperature Indicator Lamps
2-WAY
- Main Power Button ON/OFF
- AUTO/GAS Mode Selector Button
- Temperature Selector Button
- B. AC Mode Indicator Lamp
- C. GAS Mode Indicator Lamp
- D. AUTO Mode Indicator Lamp
- E. CHECK Indicator Lamp ( GAS Mode Only)
- F. Temperature Indicator Lamps
OPERATION INSTRUCTIONS
IMPORTANCE OF LEVELING A REFRIGERATOR
In an absorption refrigerator system, ammonia is liquefied in the finned
condenser coil at the top rear of the refrigerator. The liquid ammonia then
flows into the evaporator (inside the freezer section) and is exposed to a
circulating flow of hydrogen gas, which causes the ammonia to evaporate,
creating a cold condition in the freezer. When starting this refrigerator for
the very first time, the cooling cycle may require up to four hours of running
time before the cooling unit is fully operational. The tubing in the
evaporator section is specifically sloped to provide a continuous movement of
liquid ammonia, flowing downward by gravity through this section. If the
refrigerator is operated when it is not level and the vehicle is not moving,
liquid ammonia will accumulate in sections of the evaporator tubing. This will
slow the circulation of hydrogen and ammonia gas, or in severe cases,
completely block it, resulting in a loss of cooling. Any time the vehicle is
parked for several hours with the refrigerator operating, the vehicle should
be leveled to prevent this loss of cooling. The vehicle needs to be leveled
only so it is comfortable to live in (no noticeable sloping of floor or walls).
When the vehicle is moving, the leveling is not critical, as the rolling and
pitching movement of the vehicle will pass to either side of level, keeping
the liquid ammonia from accumulating in
the evaporator tubing.
OPERATION
Before starting the refrigerator, check that all the manual gas valves are in
the ON position. DO NOT forget the manual shutoff valve on the rear of the
refrigerator. This refrigerator is equipped with a control system that can be
set to automatically select either 120 volt AC or LP gas operation (AUTO
mode), or if desired LP gas only (GAS mode) or DC volts (DC Heater) where
applicable.
Auto Thermostat
In both AUTO mode and GAS mode operation, the temperature is controlled by a
factory preset temperature setting. The refrigerator controls will work down
to 9.6 volt DC.
WARNING Most LP gas appliances used in recreational vehicles are vented
to the outside of the vehicle. When parked close to a gasoline pump, it is
possible that the gasoline fumes could enter this type of appliance and ignite
from the burner flame, CAUSING A FIRE OR EXPLOSION.
FOR YOUR SAFETY, when refueling, shut off all LP gas appliances which are
vented to the outside.
OPERATION Auto Thermostat
- A continuous 12 volt DC supply must be available for the electronic control to function.
- Press the main power ON/OFF button (1) to the DOWN position.
- In AUTO mode, the AUTO lamp A will be illuminated. The control system will automatically select between AC and GAS operation with AC having priority. The temperature is controlled by a factory preset temperature setting.
- In GAS mode operation, no lamps will be illuminated and the temperature is controlled by a factory preset temperature setting.
OPERATION Adjustable Thermostat
- A continuous 12 volt DC supply must be available for the electronic control to function.
- Press the main power ON/OFF button (1) to the DOWN position.
- In AUTO mode, the AUTO lamp D will be illuminated. The control system will automatically select between AC and GAS operation with AC having priority. Temperature is selected by the user.
- In GAS mode operation, the GAS lamp C will be illuminated and only operate on LP only. Temperature is selected by user.
- In DC mode, the DC lamp A will be illuminated and the unit will only operate on DC until DC volts drops below 9.6 VDC.
Auto Mode
Press the AUTO/GAS button 2 (Auto Thermostat) or button 3 (Adjustable
Thermostat) to the DOWN position. The AUTO mode indicator lamp (A auto or D
adjustable thermostat) will illuminate. If 120 volts AC is available, the
control system will select AC operation. If 120 volts AC is not available, the
control system will automatically switch to GAS operation. Within 45 seconds
the burner should be ignited and operating normally. If the CHECK indicator
lamp (B auto or E adjustable thermostat) illuminates, the control has failed
to ignite the burner on GAS. To reset when the CHECK indicator lamp, press the
main power ON/OFF button (1) to the OFF then ON position. Systems with the new
lower control board are a three (3) try system on gas. On the initial
refrigerator start-up on gas (120 volts AC is not available), it may take
longer than 45 seconds to allow air to be purged from the gas line. If the
refrigerator has not been used for a long time or the LP tanks have just been
refilled, air may be trapped in the supply lines. To purge the air from the
lines may require resetting the main power ON/OFF button (1) three or four
times. If repeated attempts fail to start the LP gas operation, check to make
sure that the LP gas supply tanks are not empty and all manual shutoff valves
in the lines are open.
Note: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries.
GAS Mode
Move the AUTO/GAS button 2 (Auto Thermostat) or button 3 (Adjustable
Thermostat) to the UP position. The AUTO mode indicator lamp (A) will go off.
Within 45 seconds the burner should be ignited and operating normally.
DC Mode 3 Way Units Only
Press the DC mode indicator button (2) to the DOWN position. (Lamp [A] will
light). Press the TEMPERATURE SELECTOR button (4) until the lamp (F) at the
desired position is illuminated. The refrigerator will continue to operate in
the DC mode until switch (2) is moved to the UP position or control voltage
falls below 9.6 VDC. The DC mode overrides all the other operating modes.
Discharging of the battery will occur if the vehicle engine is not running.
Note: The DC mode is a holding mode not a full cool-ing mode. DC should
be used once the unit is cooled down and constant supply of DC is available
(driving down the road).
To Shut Off The Refrigerator
The refrigerator may be shut off while in any mode of operation by pressing
the main power ON/OFF button to the UP (OFF) position. This shuts off all DC
power to the control system.
Description Of Operating Modes
-
Auto Mode
When operating in the AUTO mode, the AUTO mode indicator lamp (A) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS. As soon as AC becomes available again the control will switch back to AC operation. Gas operation (120 volts AC is not available). The control system will activate the ignition system and will make three attempts to light the burner for approximately 45 seconds with two two-minute rest (purge) intervals. If unsuccessful, the CHECK indicator lamp (B) will illuminate. To restart an ignition attempt with the CHECK lamp illuminated or to clear (turn off) the CHECK lamp, press the main power ON/OFF button to the OFF position and wait a few seconds, then return to the ON position. The control system will attempt a new ignition sequence. If 120 volts AC becomes available while the CHECK indicator lamp is on, the CHECK lamp will not turn off until the main power ON/OFF button is pressed to the OFF then ON position but the unit will operate on AC. -
Gas Mode
When operating in the GAS mode, the AUTO mode indicator lamp (A) will be off. This mode provides LP gas operation only. The control system will activate the ignition system and will make three attempts to light the burner for approximately 45 seconds with two minutes approximately 45 seconds with two minutes (purge) interval after each trial. If unsuccessful, the CHECK indicator lamp (B) will illuminate. To restart GAS operation, press the main power ON/OFF button (1) to the OFF and then ON position. The control system will attempt a new ignition sequence. If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are turned on. -
DC Mode 3 Way Units Only
Press the DC mode indicator button (2) to the DOWN position. (Lamp [A] will light). Press the TEMPERATURE SELECTOR button (4) until the lamp (F) at the desired position is illuminated. The refrigerator will continue to operate in the DC mode until switch (2) is moved to the UP position or control voltage falls below 9.6 VDC. The DC mode overrides all the other operating modes. Discharging of the battery will occur if the vehicle engine is not running.
Note: The DC mode is a holding mode not a full cooling mode. DC should be used once the unit is cooled down and constant supply of DC available (driving down the road). -
To Shut Off The Refrigerator
The refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF button to the UP (OFF) position. This shuts off all DC power to the control system. -
Limp Mode
This control system contains a feature where it will continue to operate the cooling system in event of a failure of a major operating component. If the control cannot read the temperature sensor and control to the preset temperature, then the control will run the cooling unit continuously at the energy source available. The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed and the system is reset.
AC VOLTAGE
AC VOLTAGE REQUIREMENTS
WARNING This is an energized circuit. Shock can occur if not tested
properly. Testing is to be done by a qualified service technician.
The proper operating range is 100 to 132 volts. If voltage drops below 100 volts, cooling efficiency will decrease with voltage decrease. The refrigerator will not switch to another mode of operation until all AC power is lost. The refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazards, and should be plugged directly into a properly grounded three-prong receptacle.
AC COMPONENTS
- Heating Element
The heating element is designed to deliver a predetermined amount of heat to the cooling unit. To check a heating element, remove the heater leads from the printed circuit board and measure for proper resistance across the two leads with a properly calibrated ohm meter. This check is to be done with the heating element at room temperature. You should obtain the following readings ± 10%:
DC VOLTAGE
-
DC Voltage Requirements
Clean Direct Current (DC) power is mandatory for high-tech circuits to operate as designed. A battery will provide straight-line DC power. The converter and alternator produce DC power by a series of diodes that rectify alternating current to DC. The Dometic control system will only tolerate up to 6 AC volts on the DC line. AC ripple can be measured by a digital voltmeter set on the AC scale at the main DC terminal block connections at the refer. Six volts AC or less is acceptable. If AC volts exceed 6 on the DC incoming line the power source should be cleaned up. AC voltage in excess of 6 volts will affect the processor and create erratic operation. When testing for AC ripple on the DC line put a load on the converter. The operational range of the unit is a minimum of 9.6V DC to a maximum of 22V DC. The unit will automatically shut down until voltage has decreased to 18V DC. The refrigerator requires at least 9.6V DC for proper operation; however the panel lights will continue to illuminate until voltage has dropped to 4V DC or below. Do not use the body or chassis of the RV as a substitute for either of the two conductors. The refrigerator must be connected to the battery circuit with two wires of adequate capacity to avoid voltage drop. Proper polarity is crucial for refrigerator operation. No other electrical equipment or lighting should be connected to the refrigerator circuit. Just because you can read volts does not mean you have the amps to operate the control system. If relays buzz, lights go dim or out during operation, this could indicate there is a loose connection somewhere.
Main Terminal Block -
Grounds
The operation of the Dometic refrigerator is also dependent on good, clean ground connections. Loose or corroded ground terminals create an unknown resistance factor that can affect the voltage detected by the Power Module. A loose negative DC wire will create a negative millivolt signal that the control board will pick up and create erratic operation. Check the integrity of the grounds from the refrigerator all the way to the power source/battery. Clean or tighten any suspicious-looking connections.
Note: The DC terminal block below the control board should be cleaned and tightened at the 4 wires.
DC COMPONENTS
DC Heating Element
Remove the heater leads from the lower circuit board or relay and measure for
proper resistance across the two leads. You should obtain the following
readings ± 10%:
NOTE: The DC mode is a holding mode not a full cooling mode. DC should be used once the unit is cooled down on gas or AC and driving (constant supply of DC) down the road. A continuity reading will indicate an open or complete circuit. Never over or undersize the DC heater.
Thermistor
Disconnect the thermistor harness from the P2, 2-pin terminal on the lower
circuit board. Place the thermistor in a glass of ice water (more ice than
water), approximately 33° F to 35° F. Wait 8 to 10 minutes. You should get a
reading of approximately 8,000 to 10,000 ohms. Always test from the wire side
as shown with the meter as not to create a connection problem at the P2
connector.
Solenoid Valve
Check the solenoid coil with a properly calibrated ohm meter. Remove the
connectors from the solenoid and measure the resistance across the terminals.
The proper reading would be 49 ohms with tolerance range of ten percent.
Failure of the solenoid is very unlikely. Next, hook up a manometer at the
test port. Then check for DC volts at gas valve terminals (Yellow + White -)
while the unit is in trial-for-ignition. If DC volts are present and pres-sure
is low, replace the valve. If DC volts are not present at the valve while the
unit is in trial-for-ignition, verify that the wire at Plug 3, Terminal 2 on
lower circuit board has DC volts (9 or more).
Igniter
The igniter used on Dometic model refrigerators operates on 12 volt DC. On gas
operation the igniter senses the resistance through the flame between the
electrode and burner. When there is no flame at the burner, the resistance is
high and the igniter begins sparking to light the burner. As soon as the flame
is lit, the resistance between the electrode and burner drops and the igniter
stops sparking. The resistance is monitored by the igniter, and, if for any
reason the flame goes out, the igniter begins sparking until the burner is lit.
The resistance between the electrode and burner drops and the igniter stops
spark-ing.
WARNING This is an energized circuit. Shock can occur if not tested properly. Testing is to be done by a qualified service technician.
This insures that the flame will always be lit when desired. First verify proper voltage at the positive (Yellow +) and ground (Black –) terminals of the igniter. The read-ing should be within 1.5 volt of incoming voltage at the main terminal block during trial-for-ignition. Next, remove the high voltage cable from the igniter. The igniter should produce a sparking sound during trial-for-ignition. If not, replace the igniter. While operation is in the gas mode, the power module and igniter are constantly monitoring the presence of flame. If the flame is blown out, the reignitor will immediately start sparking. When the power module senses the loss of flame (thermocouple voltage below 13 MVDC) the 45 seconds trial for ignition period is started. The igniter installed on the refrigerators as original equipment is part number 2931132019 (RV Gas Model 679). This igniter is rated 50 MA. This igniter may also be used on any other model. When replacing the igniter always provide the product number for proper replacement. DO NOT install the Channel Mark 6, Model 12 E igniter (shown below) as a service replacement part. Installation of the Channel Products, Inc., Gasliter Mark 6, Model 12 E, will VOID the Warranty on the refrigerator. To acquire the proper igniter always provide the product number.
High Voltage Cable
If sparking starts during trial-for-ignition, the cable is good. If there is
no sparking during trial-for-ignition, disconnect DC power at the refrigerator
terminal block or switch unit off. Disconnect high voltage cable from
electrode. Re-connect DC power. If there is a sparking sound from the igniter
during trial-for-ignition, then replace high voltage cable or electrode. On
newer units the electrode and high-voltage cable are integrated into one
component.
Electrode
Do a visual check for cracks or breaks on the ceramic insulator. A hair line
crack can be hard to see at the electrode. The spark gap must be set at three-
sixteenths (3/16”) of an inch and tip of electrode above the slots in the
burner. When adjusting always loosen the screw and move into place, never try
to move without loosing the screw. On newer units the electrode and high-
voltage cable are integrated into one component. To acquire the proper part
always provide the product number.
DC Relay
The relay controls the circuit to the DC heating ele-ment. The load (amps) of
the DC heating element goes through the relay. Only used on newer 3 way units
or units that have the UNIVERSAL POWER MODULE KIT (3308742.000) installed.
Verify that the following components are good: upper circuit board, thermistor, 5 or 6 wire harness and 30/3-amp fuses. In the DC mode Plug 3, Terminal 4 (positive 86) and Terminal 3 (negative 85) should have voltage to close the relay. If no voltage in the DC mode change the lower board.
Wires from control board P3 harness to relay. Terminal 85 P3-3 harness blue negative. Terminal 86 P3-4 harness blue positive. Wires to relay from DC source and DC heater. Terminal 87 to DC heater positive. Terminal 30 positive from DC power source. If DC voltage to terminals 85 & 86, but no continuity between 30 & 87 the relay will need to be changed. Refer to wiring diagram on the back of the product or check parts list for proper diagram. To acquire the proper wiring diagram always use the product number.
Upper Circuit Board
With main ON/OFF switch on display panel in OFF position: Check for DC voltage
at Plug 1, Terminal 4 (orange wire +) positive and terminal 5 (red wire -)
negative DC on the lower circuit board. If no voltage, then check fuse
condition. Check for DC voltage between J4 positive and J10 negative terminals
on the lower circuit board (first generation) or J1 positive and J10 negative
on the current board (3850415013). If no voltage on orange wire, fuse test OK
and voltage into lower control, replace the lower board. Next, with main
ON/OFF switch on check for DC voltage at the upper circuit board between
terminal 4 (orange wire) and terminal 3 (red wire) which is negative (–) DC.
If no voltage and your previous check verified voltage at the lower circuit
board between the wires, test and/or replace the cable assembly between the
upper and lower controls.
Upper Board Pin Connector Wire Location
Lower Circuit Board
WIRING Original style control 3 way & 2 way
Note: 2 Way will not have a J1 for DC heater
- P1 To upper control board
- P2 Thermistor
- P3 To gas valve, igniter
- J1 To DC heater
- J2 To interior light and climate control
- J3 Negative lead from thermocouple
- J4 Positive 12V DC from terminal block
- J5 AC line voltage (Black)
- J6 AC neutral line (White)
- J7 AC neutral out to AC heater
- J8 AC line out to AC heater Switched side
- J10 Positive lead from thermocouple
Thermocouple positive lead may be on the ground strip on early units. Reference full wiring diagram next page.
WIRING: Current style control 3/2 way, 2 way will not have wires from P3 to external DC relay Board part number 3850415013
- P1 To upper control board
- P2 Thermistor
- P3 To gas valve, igniter and DC heater relay if 3 way J1 Positive 12V DC from terminal block
- J2 To interior light and climate control.
- J3 To auxiliary fan (S.) and/or ice maker heat tape
- J4 Negative lead from thermocouple
- J5 AC line voltage (Black)
- J6 AC neutral line (White)
- J7 AC neutral out to AC heater
- J8 AC line out to AC heater Switched side
- J9 Positive wire from thermocouple
- J10 Negative to Chassis ground
Note: Terminals 9 and 10 could be reversed as both terminals are ground on control board.
WIRING: Current style with integrated igniter Board part number 3850712013
- P1 To upper control board
- P2 Thermistor
- P3 To gas valve
- J2 To interior light/climate control.
- J4 Positive 12V DC from terminal block
- J5 AC line voltage (black)
- J6 AC neutral line (white)
- J7 AC neutral out to AC heater
- J8 AC line out to AC heater Switched side
- J10 Negative to Chassis ground
Note: Units that have integrated igniter do not use a thermocouple.
WIRING ORIGINAL STYLE CONTROL 3 / 2 WAY, 2 WAY WILL NOT HAVE A J1 TO DC HEATER
CURRENT CONTROL SYSTEM WIRING 2 WAY WILL NOT HAVE DC RELAY & HEATER Part number 3850415013
WIRING INTERGRATED IGNITER CONTROL Part number 3850712013
Lower Board Testing
ALL TESTS ARE TO BE DONE WITH THE REFRIGERATOR IN THE COOLING MODE.
Unplug the thermistor from the control board during lower board testing to
assure unit is calling for cooling.
DC Volts
Measure volts between terminal J4 positive (early control) and the ground and
integrated igniter board. Current control board J1 positive and ground.
Voltage should be the same as at the positive (+) and negative (–) on DC input
terminal block. 9.6 min to 22 max would be the operating range. Refer to
wiring diagram on the product number unit you are currently working on. If
voltage outside the 9.6 to 22 range, check power supply, terminal block and
correct power source before going on with the test.
-
AC Mode
Test upper control board and harness between upper and lower before testing lower for proper AC operation. Check that incoming AC voltage is present at terminals J5 (black) and J6 (white) on the circuit board. With unit on AC operation, check for voltage at the heating element connection terminals J7 and J8 on the circuit board. If no voltage is present, check the 5 amp AC, 3 amp DC fuses, wiring harness and upper control. If AC volts are present at J5 and J6 and no voltage on J7 and J8 the AC voltage detection circuit is damaged and the control board will need to be changed. -
Gas Mode
Note: All current Dometic control boards are 3 try systems in the gas mode. There is a 2 minute purge cycle between each trial for ignition. Flame failure will take 6 to 7 minutes. Verify that the following components are good: upper circuit board, thermistor, wire harness and 3-amp fuse. First, check for voltage during trial-for-ignition at Plug 3, Terminals 1 (white Wire -) and 2 (yellow wire +) to the igniter and solenoid. If no voltage is present change the circuit board. If voltage is present, check for voltage at the igniter and solenoid. If no voltage is present, check the wires. To check the flame sense circuit of the lower circuit board, operate the refrigerator on GAS and measure the milli volts between J3 (NEGATIVE) terminal original control or J4 current control and the other wire (POSITIVE) connection from the thermocouple.
The millivolts meter should read between 25 to 35 milli-volts with the gas flame burning. When the power module senses the loss of flame (thermocouple voltage below 13 MVDC) the 45 seconds trial for ignition period is started. Turning the refrigerator OFF ON while operating in the gas mode may cause a check light.
Note: A loose ground will create erratic or no gas operation on all systems. -
Gas Mode Integrated Igniter
Verify that the following components are good: upper circuit board, electrode with cable, wire harness and 3-amp fuse. Units that have integrated igniter do not have a thermocouple. The igniter senses the flame thru the electrode and communicates with the lower main control. The integrated igniter used on certain Dometic model refrigerators operates on 12 volt DC thru the control board. On gas operation the igniter senses the resistance through the flame between the electrode and burner. When there is no flame at the burner, the resistance is high and the igniter begins sparking to light the burner. As soon as the flame is lit, the resistance between the electrode and burner drops and the igniter stops sparking. The resistance is monitored by the igniter, and, if for any reason the flame goes out, the igniter begins sparking until the burner is lit. This insures that the flame will always be lit when desired. The integrated ignition system is also a three-try control. Turning the refrigerator OFF–ON while operating in the gas mode may cause a check light. If you have voltage to the gas valve during trial-for-ignition but no spark and the electrode with cable checks good, change the lower control board.
Note: Never engage the gas mode with the electrode cable unplugged from control board. This will damage the igniter on the board. -
DC Mode 3-Way Units
Verify that the following components are good: upper circuit board, wire harness, DC heater and 3/30 amp DC fuse and relay. With the DC mode selected on the upper control, the erify voltage between terminals J4 positive and the ground strip early control or J1 positive current control and J10 negative is above 9.6 min. When the DC heater is activated it will draw approximately 12 to 18 amps and if the power source is weak the control voltage will drop below proper operating range and shut down. Check for DC volts from J1 (positive) early control to DC heater, if no DC volts change the control board. On late controls (3850415013 & 3850712013 [integrated igniter]) the DC heater load (amps) goes through a stand-alone relay. In the DC mode Plug 3, Terminal 4 (positive) and Terminal 3 (negative) should have voltage to close the relay. If you have volt-age coming in with unit in DC mode but nothing out to DC heater or relay, change the control board. Refer to wiring diagram on the back of the product or check parts list for proper diagram. To acquire the proper wiring diagram always use the product number.
Door Switch
The door switch is an open switch when the switch arm is depressed (the
interior light should be off). When the refrigerator door is open the switch
is closed (interior light should be on). Check that the switch assembly is
properly aligned and that it is not broken. Check the switch assembly for
continuity. To do a continuity check, first be sure all power is disconnected
or OFF to the refrigerator. Second, remove all wires from the switch assembly,
then check the switch.
After the check, be sure the switch assembly is wired properly per the wiring
diagram. When the switch is depressed, there should not be continuity. When
the switch is NOT depressed, there should be continuity. If any of these
checks are incorrect, replace the switch.
Climate Control Heater & Switch
Not used on all units. Disconnect the wires from the switch and do a
continuity check. In the OFF position, there should be no continuity. In the
ON position, there should be a continuity reading. To check the heater itself,
perform an ohms resistance reading on the heater wire by using a properly
calibrated ohm meter. From the side of the switch that only has two wires,
with switch off take an ohm reading to ground. The proper ohms reading will be
24 ohms ± 10%. The approximate amp draw is less than .5 (1/2) amp.
Function
During the summer months of high temperatures and humidity, the metal frame
between the freezer and fresh food compartments may have water droplets
forming. The number of water droplets will increase if the vehicle isn’t air
conditioned during these months. Some refrigerators come standard with a 12
volt (DC) climate control that will evaporate the water droplets when they
form. To have the climate control on, you position the switch (normally
located beneath the top decoration panel that houses the control panel) to ON.
The approximate amp draw is less than .5 (1/2) amp.
Note: The climate control will draw 12 volt DC power continuously when in
the ON position on certain models. It should be turned OFF when a charging
source is not available or unit is in storage.
Low Ambient Switch
Not used on all units. Disconnect the wires and do a continuity check. In the
OFF position, there should be no continuity. In the ON position, there should
be a continuity reading. All RV absorption refrigerators, while similar,
operate a little differently than your home refrigerator. Do-metic designers
and engineers have equipped your refrigerator with an exclusive feature that
allows for trouble-free operation in low ambient temperature ( below 50° F)
for extended periods. Simply turn on the low ambient switch located beneath
the top decoration panel that houses the control panel. Once the outdoor
temperature is above 50° F, the low ambient switch should be turned off.
When the low ambient control is turned on it bypasses the interior light switch and turns on the interior light. The heat load of the 10 watt light bulb will cause the cooling unit to cycle approximate every 35 to 55 minutes. This will help keep the temperature in the freezer in the freezing zone. In low ambient temperatures, the freezer will warm up because the refer box will not call for much cooling. When the refer calls for cooling it will cool the freezer first and then cool the refer box. When it is cool outside the refer box won’t call for as much cooling and the freezer might warm up to normal food storage temperature (34 to 35). The second thing the control will do is keep the cooling unit from freezing up in low outdoor temperatures. (20 to 0 F)
Fuses
The 3 amp DC fuse is designed to protect the circuit board from
internal/external DC shorts. The 5 amp AC fuse is designed to protect the
integrity of the AC detection and heater circuit from shorts. On 3-way models
only, the 30 or 35- amp DC fuse is designed to protect the DC heater circuit
integrity. All fuses can be checked for continuity. If a fuse blows don’t
replace it until the problem has been found. If a fuse blows there is a short
or component that has created the problem.
Thermofuse
Newer and replacement cooling units have a Thermofuse located on the boiler.
The function of the thermofuse is to shut down the control system in the event
the cooling unit has a problem. On certain units the fuse can be reset by
pushing the button in the center. The thermofuse is a non-replaceable
component of the cooling unit. When the fuse pops it is normally an indication
the cooling unit has a problem and the cooling unit will have to be replaced.
The fuse can be checked for continuity.
LP GAS REQUIREMENTS
- WARNING DO NOT use a flame to check for gas.
- The LP gas pressure to the refrigerator should be 11 inches water column with half of all BTU’s of the RV turned on. With all other appliances off, the pressure to the refrigerator should not exceed 12 inches water column. To check the gas pressure when the refrigerator is operating, there is a pressure test port below the solenoid valve assembly.
LP GAS COMPONENTS
Manual Gas Shutoff Valve
The manual shutoff valve is a non-serviceable part. The valve is part of the
solenoid valve assembly. It is very rare to have problems with the manual
shutoff or the solenoid assemblies. If you have checked gas pressure and it is
low, check pressure at input line to refer. If pressure is 11 inches at input
and low at the pressure test port, change solenoid valve assembly. The valve
is not opening all the way.
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the refrigerant is connected to
the LP gas supply.
To test the gas safety shutoff, proceed as follows:
- Start the refrigerator according to the instructions, and switch to GAS mode.
- Check that the gas flame is lit and the GAS mode indicator lamp is on.
- Close the manual gas shutoff valve at the back of the refrigerator.
- Wait for one minute for units prior to 2003 and six to seven for units after 2003 (Three Try Board). The CHECK indicator lamp should be on and the GAS mode indicator lamp should be off.
- Remove protection cover from burner and open the manual gas shutoff valve. Do not change any button positions on the control panel. Apply a non-corrosive commercial bubble solution to the burner jet orifice.
- No bubbles should appear at the opening of the burner jet orifice. The presence of bubbles indicates a defective gas safety shutoff, and service is required.
- If no bubbles were present at the burner jet orifice, it should be rinsed with fresh water. Be careful not to damage the burner jet orifice. Replace cover and press the main power ON/OFF button (1) OFF and back ON. Nor-mal operation of the burner should return. Allow the burn-er to operate for a minimum of five minutes.
Orifice
The Dometic orifice is a brass alloy with a man-made ruby pressed in the center
that has been laser-beam drilled in a spiral pattern. The orifice is cleaned by
using an alcohol-based solvent. Soak the orifice for approximately 1 hour and
allow to air dry. Don’t insert anything in the center of the orfice it will
harm the man-made ruby. Don’t use an air nozzle to blow thru the orifice as the
ruby could be moved. Never over or under-size the orifice on a Dometic
refrigerator. The cooling unit is designed to work with a predetermined amount
of heat and modifying the orifice size will decrease cooling. If there is a
lack of cooling on gas operation, verify the orifice is the proper size per the
chart .
WARNING DO NOT use a wire or pin when cleaning the burner jet as damage
can occur to the precision opening. This can cause damage to the refrigerator
or create
a fire hazard.
Always check the parts list with the model and product number to assure the right jet size.
Thermocouple
The Thermocouple is a component that extends over the burner assembly so its
tip is in the path of the flame. During normal gas operation, the thermocouple
should produce 25 to 35 millivolts when connected to the lower circuit board.
Any reading below 18 millivolts could cause erratic gas operation.
Note: A reading of 18 or less could be caused by low gas pressure, carbon
build up or proper thermocouple location. The thermocouple should be centered
over the burner and extend over 3 slots. The control board reads negative
millivolts from the thermo-couple and the positive lead goes to the ground
terminal on the control board or ground strip.
Note: A rapid on/off of the switch or a brief interruption of DC power source does not allow the thermocouple time to cool. When the power is restored, the thermocouple has not cooled completely and the check light may come on. Turning the refrigerator OFF–ON while operating in the gas mode may cause a check light. The new lower control has built-in delay when the unit is first turned on. If the lower control reads millivolts over 6 MVDC the control will go into a 30-second gas delay before attempting to light on gas. To test the thermocouple set the meter to DC millivolts. Put the black lead from the meter to terminal J3 ( original board ) or J4 ( current board ) and the red lead from the meter to J10 or other lead from the thermocouple. Start the unit on gas and measure the DC millivolts produced by the thermocouple. The thermocouple should produce 22 to 36 millivolts within 45 seconds. If the millivolts are 20 or below erratic operation will occur. Anything below 10 to 13 the control board will not keep the gas valve energized and turn on the check light after the 45-second trial-for-ignition.
Burner
The slots in the burner should be directly below the flue tube. The burner
should be cleaned periodically, at least once a year. Soak the burner in an
alcohol-based solvent and allow to air dry. If the burner does not have a good
ground it can cause erratic gas operation. The electrode sparks to the burner
tube and an erratic ground will cause erratic gas operation.
Flue Baffle
The flue baffle ( spiral baffle ) is a twisted piece of metal that hangs in the
flue tube to slow the heat from the flame to the proper location on the cooling
unit. If the flue baffle is too high or low the heat will not be transferred to
the cooling unit properly.
Lack of heat transfer to the cooling unit will cause low cooling performance in the gas mode. It should be cleaned periodically, at least once a year. The proper position of the baffle above the burner should be as shown in the chart : Always refer to parts list on the model/product number unit you are currently working on.
Flue Cap
The flue cap is located at the top of the flue tube and is attached with a screw
or pushed down over tube. Not all units will come with a flue cap. The design
of the baffle wire in the flue tube will slow down a downdraft.
Flue Tube
Carbon build-up will not allow the heat transfer to the cooling unit and cause
lack of cooling on gas. The flue tube is welded to the boiler of the cooling
unit. In a rough riding coach there have been rare cases where the weld will
crack and create lack of cooling. The flue tube must be cleaned periodically,
at least once a year. Clean by using a flue brush, Dometic Part No. 0151404001.
COOLING UNIT
Leveling
Leveling is one of the requirements for proper operation of absorption
refrigerators. The absorption design utilizes no mechanical pumps or
compressors to circulate the refrigerant within the system, so proper leveling
must be maintained to provide the correct refrigerant flow. Without proper
leveling, refrigerant within the cooling unit will collect and stagnate at
certain areas. Without proper refrigerant flow, the cooling process will stop.
Absorption refrigerators have a type of cooling unit that utilizes an en-
closed pump tube surrounded by a solution to protect the assembly. To ensure
proper leveling, the vehicle needs to be leveled so it is comfortable to live
in. (No noticeable sloping of floor or walls). When the vehicle is moving,
leveling is not critical as the rolling and pitching movement of the vehicle
will pass to either side of level, keeping the refrigerant from accumulating
in the piping.
Ventilation
The installation shall be made in such a manner as to separate the combustion
system from the living space of the mobile home or recreational vehicle.
Openings for air supply or for venting of combustion products shall have a
minimum dimension of not less than 1/4 inch. Ventilation is a critical
requirement for proper cooling unit operation. The coach vent system must be
able to provide a way to direct the hot air, produced by the action of the
cooling unit, out away from the installation of the refrigerator. The
refrigerator extracts heat from the interior of the refrigerator cabinet and
dissipates the heat out through the vent system. In a proper installation,
there should be zero (0”) clearance surrounding the sides and top of the
refrigera-tor to achieve proper air flow. Clearance from the back of the refer
to the outside wall must be kept less than 1 inch. All potential dead air
pockets should be blocked or baffled to ensure that heat won’t be trapped in
these spaces and reduce efficiency.
Note: Refrigerators should be installed by appropriate installation
instructions received with the refrigerator.
FOR MORE UPDATED INFORMATION ON UNIQUE VENTILATION REQUIREMENTS, refer to Vent
Installation Instructions, Form No. 3308666.XXX.
Typical Roof Vent and Side Wall Vent
Typical Two Side Wall Vents
Typical Two Side Wall Vent Application. Always Refer To Vent Instructions 3308666.xxx
Air Leaks
Check the gasket on the doors to be sure of a positive air seal. A simple
method to check gaskets is to close the door on a dollar bill, then pull the
dollar bill out. If no resistance is felt, the gasket in that place is not
sealing properly. This should be done on all four sides of the door in several
places. If a gasket is not sealing properly, lift up inside of door gasket and
insert 1/4” ball of fiberglass insulation at all four corners on both doors.
This is especially important to the top corners. Next warm the gasket material
with a hair dryer. Then close the door and the magnetic strip should pull the
gasket to the metal frame. Leave door closed until the material has cooled.
Then recheck for a positive seal. If a positive seal cannot be achieved,
replace the door gasket. Also check that the cooling unit is installed
properly. The cooling unit’s foam block, the portion that surrounds the
evaporator coils, must be flush to the cabinet at the back of the refrigerator
and have a positive seal. If the cooling unit is not installed properly,
remove and install properly.
Note: Air leaks will cause insufficient cooling as well as rapid formation
of frost.
CAUTION DO NOT OVERHEAT AS YOU CAN MELT THE MATERIAL.
Another source for an air leaks could be the drain hose. When units are installed, there is a check valve at the end of the drain. At installation the hose might be shortened and the check valve must be moved to the end of drain hose. Any time lack of performance or excessive frost is experienced, look for the check valve at the end of hose.
Interior Liner Seal To Frame
There is a seal that is applied to the liner in the area where the metal frame
makes contact with the interior liner. If this seal is incomplete, cold air
can migrate out to the metal frame. If this happens, condensation could form
on the frame and could promote rapid formation of frost. If you suspect an
improper seal, apply a small bead of silicone around the perimeter where the
frame meets the interior liner. Next remove all screws securing the
refrigerator into the cabinet and slide the refrigerator out approximately 2–4
inches. Clean the metal frame and foil-backed insulation around the
refrigerator. Apply a foil-backed adhesive tape to the joint between outer
frame and foil-backed refrigerator insulation. Make sure the refrigerator is
dry and that the surface temperatures are above 50° F. Use a clear silicon
caulking compound and seal the seam between the refrigerator’s plastic liner
and the metal frame. Apply the silicon in a continuous bead around both the
refrigerator freezer and food compartments.
Note: To form a proper seal, it is important not to leave any gaps.
Door Position
If the upper or lower door is closing too high or low against the frame, cold
air leakage can occur. Adding or deleting a flat thin washer on top of the
lower or middle hinge pin can raise or lower the door position. To correct the
door alignment, loosen the hinge screws slightly and reorient the door in the
proper position. Hold the door in its new position and carefully retighten the
hinge screws.
Ambient Temperature
This is the temperature surrounding the recreational vehicle, as well as the
temperature of air at the back of the refrigerator. As the ambient temperature
increases, the air temperature in the area of the cooling unit increases.
Improper venting at this point will cause the cooling unit to have reduced
efficiency. A refer that chases the outside temperature is improperly vented or
has a weak cooling unit.
The Absorption System
- The continuous absorption type of cooling unit is operated by the application of a limited amount of heat furnished by gas, electricity or kerosene. No moving parts are employed.
- The unit consists of four main parts – the boiler, condenser, evaporator and absorber.
- The unit can be run on either electricity, kerosene or gas.
- When the unit operates on kerosene or gas the heat is supplied by a burner which is fitted underneath the central tube (A) and when the unit operates on electricity the heat is supplied by a heating element inserted in the pocket (B).
- The unit charge consists of a quantity of ammonia, water and hydrogen at a sufficient pressure to condense ammonia at the room temperature for which the unit is designed.
- When heat is supplied to the boiler system, bubbles of ammonia gas are produced which rise and carry with them quantities of weak ammonia solution through the siphon pump (C). This weak solution passes into the tube (D), while the ammonia vapor passes into the vapor pipe (E) and onto the water separator. Here any water vapor is condensed and runs back into the boiler system leaving the dry ammonia vapor to pass to the condenser.
- Air circulating over the fins of the condenser removes heat from the ammonia vapor to cause it to condense to liquid ammonia in which state it flows into the evaporator.
- The evaporator is supplied with hydrogen. The hydrogen passes across the surface of the ammonia and lowers the ammonia vapor pressure sufficiently to allow the liquid ammonia to evaporate. The evaporation of the ammonia extracts heat from the evaporator which in turn extracts heat from the food storage space, as described above, thereby lowering the temperature inside the refrigerator.
- The mixture of ammonia and hydrogen vapor passes from the evaporator to the absorber.
- Entering the upper portion of the absorber is a continous trickle of weak ammonia solution fed by gravity from the tube (D). This weak solution, flowing down through the absorber, comes into contact with the mixed ammonia and hydrogen gases which readily absorbs the ammonia from the mixture, leaving the hydrogen free to rise through the absorber coil and to return to the evaporator The hydrogen thus circulates continuously between the absorber and the evaporator.
- The strong ammonia solution produced in the absorber flows down to the absorber vessel and then to the boiler system, thus completing the full cycle of operation.
- The liquid circulation of the unit is purely gravitational.
- Heat is gencrated in the absorber by the process of absorption. This heat must be dissipated into the surrounding air.
- Heat must also be dissipated from the condenser in order to cool the ammonia vapor sufficiently for it to liquefy. Free air circulation is therefore necessary over the absorber and condenser.
- The whole unit operates by the heat applied to the boiler system and it is of paramount importance that this heat is kept within the necessary limits and is properly applied.
Cooling Unit
The cooling unit is a self-contained, hermetically sealed set of coils where
the refrigeration process takes place. The chemicals involved in the cooling
process include hydrogen, ammonia, water and a rust-inhibiting agent. There
are no repairs recommended on the cooling unit. If it is defective, replace
with a new cooling unit. To check the cooling unit, first verify the AC heating
element is good, proper ohms at room temperature, proper venting and unit is
level. Then place approximately one gallon of water inside the refrigerator
and place a thermometer in one of the containers of water. Next, unplug the
thermistor from the lower control board. This will bypass the thermostat
control and operate for at least 12 hours. Then check the temperature on the
thermometer. It should be at 43 degrees or lower depending on test conditions.
If so, the cooling unit is good. If the temperature of the water is above 43
degrees, replace the cooling unit. The outside temperature will affect the
cooling capacity of the unit. There is that rare occasion when the cooling
unit will work OK for the first 12 hours and then start to warm up. If the
customer’s complaint is “works OK for 2 to 5 days and then warms up” the unit
may have an internal problem. To test this it would be necessary to operate
the cooling unit
for up to 24 to 48 hours in the test mode.
Food Storage
Proper refrigeration requires free air circulation within the food storage
compartment. Restricted air circulation within this compartment will cause
higher cabinet temperatures. To remedy this situation, simply rearrange your
foodstuffs. It is also essential that the shelves are not covered with paper
or large storage containers. Always remember to allow for proper air
circulation. Odorous or highly flavored foods should always be stored in
covered dishes, plastic bags or wrapped in foil or waxed paper to prevent food
odors. Vegetables, lettuce, etc., should be covered to re-
tain their crispness.
NEVER PUT HOT FOOD INTO THE REFRIGERATOR.
To reduce frost formation in and on the freezing compartment, cover stored
liquids and moist foods and do not leave the door open longer than necessary.
When the refrigerator is heavily loaded, it takes a longer time for
refrigerator temperatures to lower, also increasing the ice-making time. A
very heavy load may also cause defrosting. Defrosting every 7 to 21 days would
be normal, depending on the humidity level.
High Humidity
High humidity may cause a small amount of condensation to form on the frame of
the refrigerator. In some cases it can develop to such a degree that it will
run off the frame. As the humidity is reduced, the sweating will decrease.
High humidity can also be a factor in rapid formation of frost.
WIRING
Internal Wiring
Check all wires and the connectors to ensure a proper and tight connection.
Also verify the refrigerator is wired per the wiring diagram for the model you
are working on. (See applicable wiring diagrams for your model refrigerator).
A loose connection can create erratic operation. Al-ways check the wires at
the DC terminal block, two wires in and two wires out.
External Wiring
- 120 Volts AC Connection: The refrigerator is equipped with a three prong (grounded) plug for protection against shock hazards and should be plugged directly into a prop-erly grounded three-prong receptacle. DO NOT cut or remove the grounding prong from this plug.
- 12 Volt Connection: The connection is made to the terminal block marked 12 volts DC. The control system is connected to a battery/converter circuit and could draw about 3 amps at 12 volts DC. The refrigerator must be connected to the battery circuit with two wires of adequate capacity to avoid voltage drop. Proper polarity is crucial for refrigerator operation. Don’t use the chassis for the ground circuit. No other electrical equipment or lighting should be connected to refrigerator circuit. A loose connection will create erratic operation. On three way units the DC heater will draw up to 18 AMPS and size of wires should follow installation instructions for the model unit you are working on.
Wiring Schematics
To view typical wiring schematics look in the Lower Circuit board testing
section 5, pages 14, 15 and 16. All units should have a specific schematic on
the rear of that unit. To acquire the proper one always have the product num-
ber when you call or e-mail.
ICE MAKER
Operation
The refrigerator must be allowed to precool properly before starting the ice
maker. The refrigerator has to be connected to 120 volts AC before the ice
maker can operate. The water line manual shutoff valve (not part of Dometic
unit) must be open. To start making ice, move the ice level bail arm to DOWN
position.
When the ice maker thermostat senses the preset temperature for ejection of
the ice cubes, the fingers will start to rotate, dumping any ice cubes and
filling the mold with water. When the storage container is full of ice, the ice
level bail arm cannot return to the DOWN position. This will stop further
production of ice until the container is emptied and the bail arm is returned
to the down position. The absorption system will keep the compartment at the
proper temperature for storage of ice. Ice-making is accelerated if the
thermostat is set to the coldest position. It is a good idea to do this a few
hours before you anticipate a need for ice. The first few cycles may have small
cubes due to air trapped in the water lines. The first container of ice cubes
should be dumped if the water system has been winterized or not used for
several weeks.
Note: if the ice maker was cleaned and drained, no ice cubes will be
dumped into the storage container during the first few cycles.
Mold Heater
The mold heater uses 165 watts to thaw the ice free from the mold. It is wired
in series with the thermostat which also acts as a safety device. With power
to the appliance off, check for resistance between the two leads to the heater
element. You should obtain a reading of approximately 80 ohms +/- 10%. If the
heater is found to be defective, the manufacturer recommends replacement of
the entire ice-making unit for proper operation.
Ice Ejector
The ice ejector blades sweep the ice from the mold cavities during the
ejection cycle. The drive end of the ejector is “D” shaped for positive
coupling. The bearings at both ends are lubricated with silicone grease. If
the ejector blades are frozen into the ice, defrost the ice maker and manually
cycle the ice making unit, making sure the ejector stops at the right
location.
Mold Thermostat
This is a single-pole, single-throw, bimetal switch. It starts an ejection
cycle by closing at 15º F ± 5º. The reset temperature is 50º F ± 5º. The
thermostat is in series with the mold heater and acts as a safety against
overheating in case of a mechanical failure. If the thermostat is defective,
replace it. The mold thermostat starts the ice ejection cycle. The freezer
must be down to proper temperature for the mold thermostat to start the cycle.
The cycle can be started by turning the large gear clockwise 1/8 to 1/4 of a
turn.
Shut Off Arm
The shutoff arm is cam-driven. It operates a switch to control the quantity of
ice produced. During the ejection cycle the arm is raised and lowered during
each of the two revolutions of the timing cam. If the shutoff arm comes to
rest on top of the ice in the storage bin during either revolution, the switch
will remain open and stop the ice maker at the end of that revolution. The arm
has a manual shutoff built into the linkage; by raising the arm as high as
possible, it will lock in that position until forced down. If the arm and
switch do not operate properly, check for damage and repair or replace parts
as necessary.
Mold Switches
The three switches are single-pole, double-throw style. They are identical and
interchangeable. The holding switch assures completion of a revolution once a
cycle has started. The water valve switch opens the water valve during the fill
stage of the cycle. NOTE: This is the only adjustable component of the ice
maker. If you use a double-throw switch, DO NOT use the N.O. terminal. The
shutoff switch stops the ice maker’s operation when the storage bin is full.
Timing Motor
This is a low-wattage, stall-type motor that is geared to the timing cam and
ice ejector. It is a one RPM motor. To check the motor, disconnect power to
the appliance and test for continuity between the two leads. If you DO NOT
have continuity, replace the motor. If you have continuity and the motor runs,
DO NOT replace.
Water Valve
This valve is solenoid-operated. When it is open it releases water from the
source to the mold. The amount of water is proportional to the length of time
the water valve switch is held closed by its timing cam. Disconnect power to
the appliance, remove the wires to the water valve solenoid coil, and check
for continuity between the two terminals. The ohms should be between 200 to
500. If you have continuity, the solenoid is good. It takes 10-15 watts to
energize the solenoid coil. The mold heater and coil are in series. When the
mold heater is activated, this causes the voltage to drop to about 105 VAC at
the coil. The valve has a flow washer inside which acts as a pressure
regulator. A strainer is installed to prevent dirt, rust, etc, from entering
the valve. Check for any debris which might obstruct the flow of water, or
prevent the valve from closing completely when the circuit is not energized.
Remove any obstructions. If the valve still fails to operate properly, replace
it. If the valve has been cracked from freezing this would not be a warranty
item.
Ice Maker Replacement
WARNING This is an energized circuit. Shock can occur if not tested properly. Testing is to be done by a qualified service technician.
It may be necessary to replace the entire ice maker assembly. Disconnect power to the appliance. Disconnect the 4 pin connector from the ice maker unit. Check each wire for continuity to make sure the wiring is good before replacing the ice maker unit. If there is no continuity on any of these wires, replace or repair them as necessary and recheck the ice maker unit to determine whether the problem was in the wiring or the unit itself. Remove the three screws holding the unit to the plate. Before replac-ing the ice maker assembly check the temperature in the freezer. For the unit to cycle it should be 12 degrees or cooler as the mold thermostat starts the cycle.
Water Fill Adjustment
The correct water level in the mold is important for the proper production of
ice. The size of the ice cubes depends on the amount of water that enters the
mold. The cubes should be approximately 1/2” wide, 3/4” high and 2-1/2” long.
If the water overflows in the mold, first check to see if the ice maker unit is
level in the appliance. Next ensure that the appliance is installed level in
the RV. If there is still water overflow, adjustment of the water fill screw is
necessary. Locate the screw on the ice maker assembly. Turn the screw as
necessary toward the “+” or “—” side. One full turn of the screw will make an
18 cc change in the amount of water. DO NOT turn the screw more than one full
turn at a time. If the water level is too high, it can also cause the ejector
blades to become frozen in the ice. Follow the procedures above to correct the
problem.
Water Supply
To operate properly, the water pressure in the water supply line must be
between 15 lbs. PSI and 125 lbs. PSI. Lower water pressure, water turned off,
or obstructions or air in the water line can cause low or no ice production.
First check to see that the water supply is fully turned on. Visually check
the line for kinks, etc. which might obstruct the flow of water. To remove
trapped air, loosen the connection at the water solenoid valve of the
appliance. Ensure that pressurized water is reaching this point, and bleed off
any air in the line. Retighten the connection, making sure there are no leaks.
Wiring Schematics
WARNING This is an energized circuit. Shock can occur if not tested
properly. Testing is to be done by a qualified service technician.
Refer to the wiring diagram supplied with the unit you are working on, and
make sure all wiring connections are correct and tight. 4 wires are coming
from the ice maker.
- BLACK: Connected to incoming hot from AC power source. This could be split wire at the AC BLACK at the circuit board or a separate power cord.
- WHITE: Connected to either side of the water valve and will split at the valve and hook-up to the incoming WHITE from the power source.
- GREEN/YELLOW: Connected to chassis ground. BROWN: Connected to either side of water valve.
ICE MAKER TYPICAL WIRING DIAGRAM
USA
SERVICE OFFICE
Dometic Corporation
2320 Industrial Parkway
Elkhart, IN 46516
574-294-2511
CANADA
Dometic Distribution
46 Zatonski Unit 3
Brantford, Ontario
CANADA N3T 5L8
519-720-9578
For Service Center
Assistance Call:
800-544-4881
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>